Vorwärmung M270M Gr.345S — H16, Low HI, 40–60 mm: 250°F
Bruchkritische Vorwärmanforderung für M270M Gr.345S / M270 Gr.50S bei 40–60 mm (1½–2½ in) Dicke mit Wasserstoffbezeichnung H16, gemäß AASHTO/AWS D1.5:2025, dem Brückenschweißcode.
Basierend auf AWS D1.5:2025 — jeder Wert bis zur Klausel zurückverfolgt.
M270M Gr.345S / M270 Gr.50S
AASHTO M270M Gr.345S (M270 Gr.50S) is the structural shape variant of Gr.345, intended for rolled W-shapes and channels used in bridge framing. The "S" suffix indicates the shape-specific chemistry and mechanical property requirements. Used in cross-frame angles, diaphragm members, and built-up sections where rolled shapes are specified rather than plate. Preheat requirements match Gr.345 — Table 6.3 Group 1 for NFC, Tables 12.4/12.5 for FC applications.
Die FC-Vorwärmung für M270M Gr.345S / M270 Gr.50S Verstehen
Shape-grade 345 MPa (50 ksi) steel for rolled bridge members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H16 hydrogen designation and this heat input band requires 250°F minimum preheat at 40–60 mm (1½–2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
Wo M270M Gr.345S / M270 Gr.50S Eingesetzt Wird
Used as rolled W-shapes and channels in bridge cross-frames, diaphragm members, and built-up sections. The "S" shape designation indicates procurement under AASHTO M270 with shape-specific chemistry and mandatory CVN testing. Common applications include WT sections for cross-frame members, MC channels for diaphragms, and W-shapes for floor beams on shorter spans. Weld details are primarily fillet welds at gusset connections and clip angles.
Wasserstoffkontrolle H16 für M270M Gr.345S / M270 Gr.50S
Gr.345S (50S) at H16 applies primarily to field-erected cross-frame connections using self-shielded FCAW. The higher preheat requirement at H16 can be challenging to maintain on thin shape flanges that lose heat rapidly to the surrounding air — electric resistance heating pads help maintain uniform temperature.
Warum Vorwärmung bei 40–60 mm (1½–2½ in) Wichtig ist
Material from 40 to 65 mm (1-1/2 to 2-1/2 in) covers heavy girder flanges, thick splice plates, and main member plate. This is the critical thickness range for bridge fabrication — preheat reaches 65°C (150°F) for Group 1 and 80°C (175°F) for Group 2. FC preheat at this thickness can exceed 200°C (400°F) depending on hydrogen level and heat input.
M270M Gr.345S / M270 Gr.50S bei 40–60 mm (1½–2½ in)
Gr.345S (50S) shapes at 40–65 mm flange thickness are heavy built-up members — typically W14×426 or similar jumbo sections used as pier cap beams or transfer girders. The thick flanges of these shapes require full preheat per the heavy-section tier. Welding on thick rolled sections is complicated by residual stresses from rolling — preheat helps mitigate the cumulative effect of rolling residual stress plus welding shrinkage stress.
Höhere Vorwärmung bei H16-Bezeichnung
H16-Zusatzwerkstoffe erlauben bis zu 16 mL diffusiblen Wasserstoff pro 100g — das höchste zulässige Niveau für FC-Brückenschweißen. Bei 40–60 mm (1½–2½ in) mit 1.2–2.0 kJ/mm Wärmeeinbringung kompensiert die Vorwärmung von 250°F (120°C) das höhere Wasserstoffpotential.
Andere Brückenstähle bei H16 1.2–2.0 kJ/mm · 40–60 mm (1½–2½ in)
| Stahl | Tabelle | Vorwärmung |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 250°F (120°C) |
| M270M Gr.345W / M270 Gr.50W | B | 350°F (180°C) |
| M270M HPS345W / M270 HPS50W | B | 350°F (180°C) |
| M270M HPS485W / M270 HPS70W | B | 350°F (180°C) |
M270M Gr.345S / M270 Gr.50S bei H16 1.2–2.0 kJ/mm
Verschiedene Kombinationen Ausprobieren
Verwenden Sie den D1.5 Brücken-Vorwärmrechner für jeden AASHTO M270 Stahl, Wasserstoffniveau und Wärmeeinbringungskombination. Siehe auch den D1.1 Vorwärmrechner für Baustahl.
Verwandte Leitfäden