AASHTO/AWS D1.5:2025 · Tabela 12.4/12.5 · Fratura Crítica · H8

Pré-aquecimento M270M Gr.250 — H8, Mid HI, > 60 mm: 300°F

Requisito de pré-aquecimento de fratura crítica para M270M Gr.250 / M270 Gr.36 em espessura > 60 mm (> 2½ in) com designação de hidrogênio H8, conforme AASHTO/AWS D1.5:2025.

Baseado na AWS D1.5:2025 — cada valor rastreado à cláusula.

Pré-aquecimento e Interpasse Mínimo de Fratura Crítica
300°F / 150°C
Hidrogênio H8 · aporte de calor 2.0–2.8 kJ/mm · espessura > 60 mm (> 2½ in)
AASHTO/AWS D1.5M/D1.5:2025 Tabela 12.4/12.5
Designação H8: o consumível deposita ≤ 8 mL/100g de hidrogênio difusível conforme AWS A4.3. Menor hidrogênio = menor pré-aquecimento.
Ferramenta de referência. Verificar contra a edição aplicável ao projeto e EPS aprovada pelo Engenheiro.

M270M Gr.250 / M270 Gr.36

AASHTO M270M Gr.250 (M270 Gr.36) is the metric/US customary designation for the basic structural bridge steel with 250 MPa (36 ksi) minimum yield. It is the direct bridge equivalent of ASTM A709 Gr.36, procured under AASHTO M270 with mandatory Charpy V-notch testing per temperature zone. Used for secondary bridge members — lateral bracing, diaphragm plates, floor beam stiffeners, and bearing components where Gr.345 strength is not needed. Non-fracture-critical preheat follows Table 6.3 Group 1; fracture-critical follows Tables 12.4/12.5 with hydrogen and heat input as additional variables.

Entendendo o Pré-aquecimento FC para M270M Gr.250 / M270 Gr.36

Basic 250 MPa (36 ksi) bridge steel for secondary members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H8 hydrogen designation and this heat input band requires 300°F minimum preheat at > 60 mm (> 2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Onde M270M Gr.250 / M270 Gr.36 é Usado

Specified for secondary bridge members under AASHTO LRFD — lateral bracing angles, diaphragm plates, floor beam stiffeners, bearing seat components, and railing posts. Gr.250 (36) requires CVN testing per AASHTO temperature zone, distinguishing it from plain ASTM A36 by guaranteeing fracture resistance at the bridge design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details. Temperature zones (1 through 3) determine CVN test temperature: Zone 1 at 21°C (70°F) for moderate climates, Zone 2 at 4°C (40°F) for cold, Zone 3 at -12°C (10°F) for severe cold.

Controle de Hidrogênio H8 para M270M Gr.250 / M270 Gr.36

H8 designation (8 mL/100g max) on Gr.250 (36) provides a balanced approach between preheat economy and consumable availability. Most structural SMAW electrodes and FCAW wires carry H8 classification as the standard low-hydrogen tier. For secondary bridge members, H8 is typically the default specification unless the Engineer specifically mandates H4.

Por que o Pré-aquecimento Importa em > 60 mm (> 2½ in)

Material over 65 mm (2-1/2 in) includes the heaviest bridge girder flanges and box-section walls. Table 6.3 requires 110°C (225°F) for both groups at this thickness. Extended preheat soak time is necessary to achieve uniform through-thickness temperature. FC preheat for the heaviest sections reaches 180–200°C (350–400°F) at the H16 hydrogen level.

M270M Gr.250 / M270 Gr.36 em > 60 mm (> 2½ in)

Gr.250 (36) above 65 mm is rare — typically only in large bearing assemblies or rehabilitation projects repairing older bridges where original plate was overspecified. Preheat soak-through at 225°F requires flame heating on both sides for 15–20 minutes on plate this thick. The cost of preheat compliance at this thickness often triggers a design review to consider switching to Gr.345 which achieves the same capacity with thinner, lighter sections.

Outros Aços de Ponte em H8 2.0–2.8 kJ/mm · > 60 mm (> 2½ in)

AçoTabelaPré-aquecimento
M270M Gr.345 / M270 Gr.50A300°F (150°C)
M270M Gr.345W / M270 Gr.50WB350°F (180°C)
M270M HPS345W / M270 HPS50WB350°F (180°C)
M270M HPS485W / M270 HPS70WB350°F (180°C)

Experimente Diferentes Combinações

Use a Calculadora de Pré-aquecimento D1.5 para Pontes para consultar qualquer aço AASHTO M270, nível de hidrogênio e combinação de aporte de calor. Veja também a Calculadora de Pré-aquecimento D1.1 para aço estrutural.

Qual é o pré-aquecimento FC para M270M Gr.250 / M270 Gr.36 com H8 em > 60 mm (> 2½ in)?
Para fratura crítica M270M Gr.250 / M270 Gr.36 soldado com consumíveis designados H8 em espessura > 60 mm (> 2½ in) e aporte de calor 2.0–2.8 kJ/mm, o pré-aquecimento mínimo é 300°F (150°C) conforme D1.5 Tabela 12.4/12.5.
Qual é a diferença entre pré-aquecimento FC e NFC para M270M Gr.250 / M270 Gr.36?
O pré-aquecimento não fratura crítica (Tabela 6.3) é uma consulta simples baseada em espessura. O de fratura crítica (Tabelas 12.4–12.8) adiciona nível de hidrogênio e aporte de calor como variáveis.
Como o aporte de calor afeta o pré-aquecimento FC de M270M Gr.250 / M270 Gr.36?
Maior aporte de calor significa taxas de resfriamento mais lentas, dando mais tempo ao hidrogênio para se difundir para fora da zona de solda. Em 2.0–2.8 kJ/mm, o pré-aquecimento de 300°F equilibra o nível de hidrogênio e a taxa de resfriamento.
Why is preheat the same for both groups above 65 mm?
Table 6.3 converges at 110°C (225°F) for both groups at this thickness because the dominant factor becomes hydrogen diffusion distance through the thick section rather than the steel’s hardenability. Even Group 1 steels need substantial preheat at 65+ mm to keep cooling rates slow enough for safe hydrogen escape.

Dados de referência D1.5:2025. Sem afiliação com AWS ou AASHTO.