M270M Gr.345W予熱 — H16、Mid HI、20–40 mm: 225°F
AASHTO/AWS D1.5:2025(橋梁溶接規格)に基づく、20–40 mm (3/4–1½ in)板厚、水素指定H16でのにおけるM270M Gr.345W / M270 Gr.50Wの破壊臨界予熱要件。
AWS D1.5:2025に基づく — すべての値は条項に追跡可能。
M270M Gr.345W / M270 Gr.50W
AASHTO M270M Gr.345W (M270 Gr.50W) is a weathering bridge steel with 345 MPa (50 ksi) yield that forms a protective oxide patina for unpainted bridge service. The copper-chromium-nickel alloying provides atmospheric corrosion resistance, eliminating lifetime repainting costs estimated at $15–25 per square foot per cycle. Weld filler must match the weathering composition (E8018-W2 or equivalent) for exposed joints. NFC preheat per Table 6.3 Group 1; FC per Tables 12.6/12.7 which carry higher preheat than the non-weathering grades.
M270M Gr.345W / M270 Gr.50WのFC予熱を理解する
Weathering 345 MPa (50 ksi) bridge steel for unpainted service. Under D1.5 fracture-critical requirements (Clause 12), the combination of H16 hydrogen designation and this heat input band requires 225°F minimum preheat at 20–40 mm (3/4–1½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
M270M Gr.345W / M270 Gr.50Wの使用箇所
Deployed in unpainted bridge plate girders across humid, coastal, and high-maintenance-cost environments. The weathering patina eliminates lifetime repainting cycles estimated at $15–25/sq ft per cycle. Weld filler must match the weathering composition (E8018-W2 or ER80S-G-W) for exposed joints to ensure the weld face develops the same protective oxide as the base metal. Conventional Gr.345W is being replaced by HPS345W in new designs due to superior weldability.
M270M Gr.345W / M270 Gr.50WにおけるH16水素管理
Weathering Gr.345W (50W) at H16 is used for field splices when self-shielded FCAW is the only practical process due to wind exposure on elevated bridge erection. The significantly higher preheat at H16 — often 40–60°F above H4 — makes weather-window scheduling critical for winter field splice operations.
20–40 mm (3/4–1½ in)で予熱が重要な理由
Material from 20 to 40 mm (3/4 to 1-1/2 in) includes many girder web plates, splice plates, and bearing stiffener plates. Preheat increases to 20°C (70°F) for Group 1 and 50°C (125°F) for Group 2 under Table 6.3. The thicker section slows hydrogen diffusion, requiring higher preheat to maintain safe cooling rates.
20–40 mm (3/4–1½ in)でのM270M Gr.345W / M270 Gr.50W
At 20–40 mm, Gr.345W (50W) serves as the primary plate for unpainted bridge girder webs and connection plates. Weathering steel butt splices require the same CJP quality as painted Gr.345 but with compositional matching of the filler metal. Improper filler selection leaves a cosmetically distinct weld face that does not develop the same protective oxide, creating a maintenance concern on exposed bridges.
H16指定での高い予熱
H16溶接材料は100gあたり最大16mLの拡散性水素を許容します — 橋梁FC溶接で許可される最高レベルです。2.0–2.8 kJ/mm入熱での20–40 mm (3/4–1½ in)では、225°F (110°C)予熱が高い水素ポテンシャルを補います。この継手にH8またはH4溶接材料に切り替えると必要な予熱が低下します。
H16 2.0–2.8 kJ/mm · 20–40 mm (3/4–1½ in)における他の橋梁鋼材
| 鋼材 | 表 | 予熱 |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 175°F (80°C) |
| M270M Gr.345 / M270 Gr.50 | A | 175°F (80°C) |
| M270M Gr.345S / M270 Gr.50S | A | 175°F (80°C) |
| M270M HPS345W / M270 HPS50W | B | 225°F (110°C) |
H16 2.0–2.8 kJ/mmでのM270M Gr.345W / M270 Gr.50W
別の組み合わせを試す
D1.5橋梁予熱計算機を使用して、AASHTO M270鋼材の水素レベルと入熱の任意の組み合わせを検索できます。構造用鋼にはD1.1予熱計算機もご覧ください。
関連ガイド
D1.5:2025参考データ。AWSおよびAASHTOとの提携なし。