AASHTO/AWS D1.5:2025 · Tabella 12.6/12.7 · Frattura Critica · H8

Preriscaldo M270M Gr.345W — H8, Mid HI, ≤ 20 mm: 100°F

Requisito di preriscaldo di frattura critica per M270M Gr.345W / M270 Gr.50W a spessore ≤ 20 mm (3/4 in) con designazione idrogeno H8, secondo AASHTO/AWS D1.5:2025, il Codice di Saldatura dei Ponti.

Basato su AWS D1.5:2025 — ogni valore tracciato alla clausola.

Preriscaldo e Interpass Minimo di Frattura Critica
100°F / 40°C
Idrogeno H8 · apporto termico 2.0–2.8 kJ/mm · spessore ≤ 20 mm (3/4 in)
AASHTO/AWS D1.5M/D1.5:2025 Tabella 12.6/12.7
Designazione H8: il consumabile deposita ≤ 8 mL/100g di idrogeno diffusibile secondo AWS A4.3. Meno idrogeno = meno preriscaldo.
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

M270M Gr.345W / M270 Gr.50W

AASHTO M270M Gr.345W (M270 Gr.50W) is a weathering bridge steel with 345 MPa (50 ksi) yield that forms a protective oxide patina for unpainted bridge service. The copper-chromium-nickel alloying provides atmospheric corrosion resistance, eliminating lifetime repainting costs estimated at $15–25 per square foot per cycle. Weld filler must match the weathering composition (E8018-W2 or equivalent) for exposed joints. NFC preheat per Table 6.3 Group 1; FC per Tables 12.6/12.7 which carry higher preheat than the non-weathering grades.

Comprendere il Preriscaldo FC per M270M Gr.345W / M270 Gr.50W

Weathering 345 MPa (50 ksi) bridge steel for unpainted service. Under D1.5 fracture-critical requirements (Clause 12), the combination of H8 hydrogen designation and this heat input band requires 100°F minimum preheat at ≤ 20 mm (3/4 in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Dove Viene Usato M270M Gr.345W / M270 Gr.50W

Deployed in unpainted bridge plate girders across humid, coastal, and high-maintenance-cost environments. The weathering patina eliminates lifetime repainting cycles estimated at $15–25/sq ft per cycle. Weld filler must match the weathering composition (E8018-W2 or ER80S-G-W) for exposed joints to ensure the weld face develops the same protective oxide as the base metal. Conventional Gr.345W is being replaced by HPS345W in new designs due to superior weldability.

Controllo Idrogeno H8 per M270M Gr.345W / M270 Gr.50W

Weathering Gr.345W (50W) with H8 represents the standard practice for most unpainted bridge fabrication. Gas-shielded FCAW wires commonly achieve H8 designation, making this the natural hydrogen level for high-productivity shop welding on weathering grade plate girders.

Perché il Preriscaldo è Importante a ≤ 20 mm (3/4 in)

Material up to 20 mm (3/4 in) covers most cross-frame angles, stiffener clips, lateral bracing members, and light bridge plate. At this thickness, hydrogen diffusion is efficient and preheat requirements are the lowest in Table 6.3 — 10°C (50°F) for both groups. In FC service, this thickness tier also carries the lowest preheat in Tables 12.4–12.7, starting at 40°C (100°F) for H4 consumables.

M270M Gr.345W / M270 Gr.50W a ≤ 20 mm (3/4 in)

Gr.345W (50W) weathering steel at thin plate thickness appears in unpainted bridge bearing stiffeners and web attachment plates exposed to the atmosphere. Filler metal must match the weathering composition — E8018-W2 for SMAW or ER80S-G-W for GMAW. The patina development on thin plate is rapid (6–18 months) but requires proper drainage detailing to prevent pack rust between closely spaced plates.

Altri Acciai da Ponte a H8 2.0–2.8 kJ/mm · ≤ 20 mm (3/4 in)

AcciaioTabellaPreriscaldo
M270M Gr.250 / M270 Gr.36A100°F (40°C)
M270M Gr.345 / M270 Gr.50A100°F (40°C)
M270M Gr.345S / M270 Gr.50SA100°F (40°C)
M270M HPS345W / M270 HPS50WB100°F (40°C)

Prova Diverse Combinazioni

Usa il Calcolatore Preriscaldo D1.5 per Ponti per consultare qualsiasi acciaio AASHTO M270, livello di idrogeno e combinazione di apporto termico. Vedi anche il Calcolatore Preriscaldo D1.1 per acciaio strutturale.

Qual è il preriscaldo FC per M270M Gr.345W / M270 Gr.50W con H8 a ≤ 20 mm (3/4 in)?
Per frattura critica M270M Gr.345W / M270 Gr.50W saldato con consumabili designati H8 a spessore ≤ 20 mm (3/4 in) e apporto termico 2.0–2.8 kJ/mm, il preriscaldo minimo è 100°F (40°C) secondo D1.5 Tabella 12.6/12.7.
Qual è la differenza tra preriscaldo FC e NFC per M270M Gr.345W / M270 Gr.50W?
Il preriscaldo non frattura critica (Tabella 6.3) è una consultazione semplice basata sullo spessore. Il preriscaldo frattura critica (Tabelle 12.4–12.8) aggiunge livello di idrogeno e apporto termico come variabili, richiedendo tipicamente un preriscaldo più elevato.
Come influisce l'apporto termico sul preriscaldo FC di M270M Gr.345W / M270 Gr.50W?
Un apporto termico più elevato significa velocità di raffreddamento più lente, dando più tempo all'idrogeno per diffondersi fuori dalla zona di saldatura. A 2.0–2.8 kJ/mm, il preriscaldo di 100°F bilancia il livello di idrogeno e la velocità di raffreddamento.
Is preheat needed for bridge steel under 20 mm?
Yes — D1.5 Table 6.3 requires a minimum of 10°C (50°F) even for the thinnest material in both groups. This is higher than D1.1’s Category B minimum of 0°C (32°F) at the same thickness, reflecting the more conservative approach for bridge structures where fracture consequences are severe.