Preriscaldo M270M Gr.345S — H8, Low HI, 40–60 mm: 225°F
Requisito di preriscaldo di frattura critica per M270M Gr.345S / M270 Gr.50S a spessore 40–60 mm (1½–2½ in) con designazione idrogeno H8, secondo AASHTO/AWS D1.5:2025, il Codice di Saldatura dei Ponti.
Basato su AWS D1.5:2025 — ogni valore tracciato alla clausola.
M270M Gr.345S / M270 Gr.50S
AASHTO M270M Gr.345S (M270 Gr.50S) is the structural shape variant of Gr.345, intended for rolled W-shapes and channels used in bridge framing. The "S" suffix indicates the shape-specific chemistry and mechanical property requirements. Used in cross-frame angles, diaphragm members, and built-up sections where rolled shapes are specified rather than plate. Preheat requirements match Gr.345 — Table 6.3 Group 1 for NFC, Tables 12.4/12.5 for FC applications.
Comprendere il Preriscaldo FC per M270M Gr.345S / M270 Gr.50S
Shape-grade 345 MPa (50 ksi) steel for rolled bridge members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H8 hydrogen designation and this heat input band requires 225°F minimum preheat at 40–60 mm (1½–2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
Dove Viene Usato M270M Gr.345S / M270 Gr.50S
Used as rolled W-shapes and channels in bridge cross-frames, diaphragm members, and built-up sections. The "S" shape designation indicates procurement under AASHTO M270 with shape-specific chemistry and mandatory CVN testing. Common applications include WT sections for cross-frame members, MC channels for diaphragms, and W-shapes for floor beams on shorter spans. Weld details are primarily fillet welds at gusset connections and clip angles.
Controllo Idrogeno H8 per M270M Gr.345S / M270 Gr.50S
For Gr.345S (50S) rolled shapes, H8 is adequate for most connection details where the weld length is short and access allows proper preheat application. Cross-frame gusset connections rarely justify the cost premium of H4 consumables when H8 meets the FC preheat budget.
Perché il Preriscaldo è Importante a 40–60 mm (1½–2½ in)
Material from 40 to 65 mm (1-1/2 to 2-1/2 in) covers heavy girder flanges, thick splice plates, and main member plate. This is the critical thickness range for bridge fabrication — preheat reaches 65°C (150°F) for Group 1 and 80°C (175°F) for Group 2. FC preheat at this thickness can exceed 200°C (400°F) depending on hydrogen level and heat input.
M270M Gr.345S / M270 Gr.50S a 40–60 mm (1½–2½ in)
Gr.345S (50S) shapes at 40–65 mm flange thickness are heavy built-up members — typically W14×426 or similar jumbo sections used as pier cap beams or transfer girders. The thick flanges of these shapes require full preheat per the heavy-section tier. Welding on thick rolled sections is complicated by residual stresses from rolling — preheat helps mitigate the cumulative effect of rolling residual stress plus welding shrinkage stress.
Altri Acciai da Ponte a H8 1.2–2.0 kJ/mm · 40–60 mm (1½–2½ in)
| Acciaio | Tabella | Preriscaldo |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 225°F (110°C) |
| M270M Gr.345W / M270 Gr.50W | B | 325°F (160°C) |
| M270M HPS345W / M270 HPS50W | B | 325°F (160°C) |
| M270M HPS485W / M270 HPS70W | B | 325°F (160°C) |
M270M Gr.345S / M270 Gr.50S a H8 1.2–2.0 kJ/mm
Prova Diverse Combinazioni
Usa il Calcolatore Preriscaldo D1.5 per Ponti per consultare qualsiasi acciaio AASHTO M270, livello di idrogeno e combinazione di apporto termico. Vedi anche il Calcolatore Preriscaldo D1.1 per acciaio strutturale.
Guide Correlate
Dati di riferimento D1.5:2025. Non affiliato con AWS o AASHTO.