AASHTO/AWS D1.5:2025 · Tabella 12.4/12.5 · Frattura Critica · H8

Preriscaldo M270M Gr.250 — H8, Low HI, 40–60 mm: 225°F

Requisito di preriscaldo di frattura critica per M270M Gr.250 / M270 Gr.36 a spessore 40–60 mm (1½–2½ in) con designazione idrogeno H8, secondo AASHTO/AWS D1.5:2025, il Codice di Saldatura dei Ponti.

Basato su AWS D1.5:2025 — ogni valore tracciato alla clausola.

Preriscaldo e Interpass Minimo di Frattura Critica
225°F / 110°C
Idrogeno H8 · apporto termico 1.2–2.0 kJ/mm · spessore 40–60 mm (1½–2½ in)
AASHTO/AWS D1.5M/D1.5:2025 Tabella 12.4/12.5
Designazione H8: il consumabile deposita ≤ 8 mL/100g di idrogeno diffusibile secondo AWS A4.3. Meno idrogeno = meno preriscaldo.
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

M270M Gr.250 / M270 Gr.36

AASHTO M270M Gr.250 (M270 Gr.36) is the metric/US customary designation for the basic structural bridge steel with 250 MPa (36 ksi) minimum yield. It is the direct bridge equivalent of ASTM A709 Gr.36, procured under AASHTO M270 with mandatory Charpy V-notch testing per temperature zone. Used for secondary bridge members — lateral bracing, diaphragm plates, floor beam stiffeners, and bearing components where Gr.345 strength is not needed. Non-fracture-critical preheat follows Table 6.3 Group 1; fracture-critical follows Tables 12.4/12.5 with hydrogen and heat input as additional variables.

Comprendere il Preriscaldo FC per M270M Gr.250 / M270 Gr.36

Basic 250 MPa (36 ksi) bridge steel for secondary members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H8 hydrogen designation and this heat input band requires 225°F minimum preheat at 40–60 mm (1½–2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Dove Viene Usato M270M Gr.250 / M270 Gr.36

Specified for secondary bridge members under AASHTO LRFD — lateral bracing angles, diaphragm plates, floor beam stiffeners, bearing seat components, and railing posts. Gr.250 (36) requires CVN testing per AASHTO temperature zone, distinguishing it from plain ASTM A36 by guaranteeing fracture resistance at the bridge design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details. Temperature zones (1 through 3) determine CVN test temperature: Zone 1 at 21°C (70°F) for moderate climates, Zone 2 at 4°C (40°F) for cold, Zone 3 at -12°C (10°F) for severe cold.

Controllo Idrogeno H8 per M270M Gr.250 / M270 Gr.36

H8 designation (8 mL/100g max) on Gr.250 (36) provides a balanced approach between preheat economy and consumable availability. Most structural SMAW electrodes and FCAW wires carry H8 classification as the standard low-hydrogen tier. For secondary bridge members, H8 is typically the default specification unless the Engineer specifically mandates H4.

Perché il Preriscaldo è Importante a 40–60 mm (1½–2½ in)

Material from 40 to 65 mm (1-1/2 to 2-1/2 in) covers heavy girder flanges, thick splice plates, and main member plate. This is the critical thickness range for bridge fabrication — preheat reaches 65°C (150°F) for Group 1 and 80°C (175°F) for Group 2. FC preheat at this thickness can exceed 200°C (400°F) depending on hydrogen level and heat input.

M270M Gr.250 / M270 Gr.36 a 40–60 mm (1½–2½ in)

Gr.250 (36) at 40–65 mm is uncommon in modern designs because Gr.345 handles the same loads at lighter weight. When specified, it appears in bearing seats and massive foundation assemblies where material cost is secondary to simplicity. At this thickness the HAZ cooling rate is significantly slower, and the 150°F preheat reflects the need to keep cooling rates below the critical rate for hydrogen-induced cracking in the coarse-grained HAZ.

Altri Acciai da Ponte a H8 1.2–2.0 kJ/mm · 40–60 mm (1½–2½ in)

AcciaioTabellaPreriscaldo
M270M Gr.345 / M270 Gr.50A225°F (110°C)
M270M Gr.345W / M270 Gr.50WB325°F (160°C)
M270M HPS345W / M270 HPS50WB325°F (160°C)
M270M HPS485W / M270 HPS70WB325°F (160°C)

Prova Diverse Combinazioni

Usa il Calcolatore Preriscaldo D1.5 per Ponti per consultare qualsiasi acciaio AASHTO M270, livello di idrogeno e combinazione di apporto termico. Vedi anche il Calcolatore Preriscaldo D1.1 per acciaio strutturale.

Qual è il preriscaldo FC per M270M Gr.250 / M270 Gr.36 con H8 a 40–60 mm (1½–2½ in)?
Per frattura critica M270M Gr.250 / M270 Gr.36 saldato con consumabili designati H8 a spessore 40–60 mm (1½–2½ in) e apporto termico 1.2–2.0 kJ/mm, il preriscaldo minimo è 225°F (110°C) secondo D1.5 Tabella 12.4/12.5.
Qual è la differenza tra preriscaldo FC e NFC per M270M Gr.250 / M270 Gr.36?
Il preriscaldo non frattura critica (Tabella 6.3) è una consultazione semplice basata sullo spessore. Il preriscaldo frattura critica (Tabelle 12.4–12.8) aggiunge livello di idrogeno e apporto termico come variabili, richiedendo tipicamente un preriscaldo più elevato.
Come influisce l'apporto termico sul preriscaldo FC di M270M Gr.250 / M270 Gr.36?
Un apporto termico più elevato significa velocità di raffreddamento più lente, dando più tempo all'idrogeno per diffondersi fuori dalla zona di saldatura. A 1.2–2.0 kJ/mm, il preriscaldo di 225°F bilancia il livello di idrogeno e la velocità di raffreddamento.
What preheat is needed for 50 mm thick bridge plate?
For non-fracture-critical: 65°C (150°F) for Group 1 grades, 80°C (175°F) for Group 2. For fracture-critical: consult Tables 12.4–12.8 based on the specific steel grade, hydrogen designator, and heat input. FC preheat at this thickness is typically 90–200°C (200–400°F) depending on those variables.

Dati di riferimento D1.5:2025. Non affiliato con AWS o AASHTO.