AWS D1.1:2025 · Tabel 5.11 · Kategori A

Preheat A500 Gr.B/C untuk SMAW (non-low-hydrogen) — over 2-1/2"

Suhu pemanasan awal dan antar lajur minimum untuk A500 Gr.B/C dilas dengan SMAW (non-low-hydrogen) pada ketebalan over 2-1/2", sesuai AWS D1.1:2025 Tabel 5.11.

Berdasarkan AWS D1.1:2025 Tabel 5.11 — setiap nilai dilacak ke pasal.

Suhu Minimum Pemanasan Awal dan Antar Lajur
300°F / 150°C
Kategori A
Proses SMAW bukan hidrogen rendah
AWS D1.1:2025 Tabel 5.11, §5.7
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For common structural shapes and plate, non-low-hydrogen SMAW with E6010 or E6011 excels at root passes on open-root groove welds where burn-through control matters. Vertical-up technique with a slight weave keeps the puddle manageable. Rod consumption runs about 10-12 electrodes per pound of weld metal deposited. Electrode stubs should be no shorter than 2 inches to maintain adequate arc length control.

A500 Gr.B/C

ASTM A500 Grade B (46 ksi yield for round, 42 ksi for rectangular) and Grade C (50 ksi round, 46 ksi rectangular) cover cold-formed welded and seamless structural tubing — round, square, and rectangular HSS sections. These are the standard tubular members in building frames, trusses, and signage structures, produced in wall thicknesses from 16 gauge (0.065") up to 5/8" for rectangular and 1/2" for round. Table 5.11 assigns both Category A and B preheat requirements. The cold-forming process work-hardens the corners, producing corner radii with higher hardness (up to 20% increase) and reduced ductility compared to the flat faces. This affects welding behavior at corner locations, particularly on heavily loaded connection details where weld starts or stops near corner radii can create initiation points for fatigue cracks.

Mengapa Preheat Ini untuk A500 Gr.B/C dengan SMAW

Cold-formed structural tubing for HSS sections in frames and trusses. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Aplikasi Umum untuk A500 Gr.B/C

Standard for HSS columns in office buildings, hollow section trusses in warehouse roofs, exposed architectural tube steel, sign structures, solar panel racking frames, greenhouse frames, and guard rail posts. A500 tube-to-tube moment connections require through-plate or diaphragm detailing to transfer forces across the closed section. Slotted gusset connections into HSS bracing members are a signature fabrication detail requiring careful fit-up and beveling of the gusset plate. Common sizes include HSS 6x6x3/8 and HSS 8x8x1/2 for columns, HSS 4x4x1/4 for bracing, and HSS 10x6x3/8 for rectangular beam applications. The cold-formed corner radius creates a heat-affected zone consideration that differs from hot-rolled shapes when planning multi-pass weld sequences. Round HSS pipe columns are also common, typically HSS 6.625x0.280 through HSS 12.750x0.500 for mezzanine posts and canopy supports. Fillet welds connecting HSS to cap plates and base plates are the most frequent weld joint detail.

Mengapa Preheat Penting pada over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Baja Lain dengan SMAW (non-low-hydrogen) pada over 2-1/2"

BajaKategoriPreheat
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

A500 Gr.B/C dengan SMAW (non-low-hydrogen)

Coba Kombinasi Berbeda

Gunakan kalkulator preheat interaktif untuk mencari kombinasi baja, proses, dan ketebalan dari D1.1:2025 Tabel 5.11.

Berapa preheat minimum untuk A500 Gr.B/C dengan SMAW pada over 2-1/2"?
Untuk A500 Gr.B/C dilas dengan SMAW (non-low-hydrogen) pada ketebalan over 2-1/2", suhu preheat minimum adalah 300°F (150°C) sesuai AWS D1.1:2025 Tabel 5.11, Kategori A.
Kategori Tabel 5.11 apa yang berlaku untuk A500 Gr.B/C dengan SMAW?
A500 Gr.B/C dilas dengan SMAW (non-low-hydrogen) termasuk Kategori A di AWS D1.1:2025 Tabel 5.11. Proses SMAW bukan hidrogen rendah. Pada ketebalan over 2-1/2", kategori ini memerlukan preheat minimum 300°F (150°C).
Mengapa preheat 300°F untuk A500 Gr.B/C pada over 2-1/2"?
Preheat 300°F untuk A500 Gr.B/C pada over 2-1/2" dengan SMAW (non-low-hydrogen) mencerminkan kombinasi kemampuan pengerasan baja dan peningkatan pengekangan pada ketebalan ini.

Data referensi D1.1:2025. Tidak berafiliasi dengan AWS.