AWS D1.1:2025 · Tabel 5.11 · Kategori C

Preheat A1066 Gr.70 untuk SMAW (low-hydrogen) — over 2-1/2"

Suhu pemanasan awal dan antar lajur minimum untuk A1066 Gr.70 dilas dengan SMAW (low-hydrogen) pada ketebalan over 2-1/2", sesuai AWS D1.1:2025 Tabel 5.11.

Berdasarkan AWS D1.1:2025 Tabel 5.11 — setiap nilai dilacak ke pasal.

Suhu Minimum Pemanasan Awal dan Antar Lajur
300°F / 150°C
Kategori C
Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah (baja kekuatan tinggi)
AWS D1.1:2025 Tabel 5.11, §5.7
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A1066 Gr.70

ASTM A1066 Grade 70 (70 ksi yield, 85 ksi minimum tensile) is the highest-strength grade in this specification, produced as quenched-and-tempered or TMCP plate for demanding bridge and structural applications. It falls under Category C in Table 5.11 but notably does not qualify for any H8 reduced-preheat category — unlike Grades 50/60/65, Grade 70 must use full Category C preheat regardless of consumable hydrogen designation. This distinction exists because the higher alloying level needed for 70 ksi yield pushes the CE-IIW to approximately 0.48-0.54, a range where even H8 hydrogen control is not sufficient to offset the hardenability-driven cracking risk at reduced preheat. Fabricators working with A1066 Gr.70 should budget for full Category C preheating time on every joint, with no H8 shortcut available.

Mengapa Preheat Ini untuk A1066 Gr.70 dengan SMAW-LH

Highest-strength A1066 at 70 ksi with no H8 preheat reduction available. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 300°F minimum with SMAW-LH, the preheat ensures the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material. Category C steels demand careful attention to interpass temperature control throughout the weld sequence.

Aplikasi Umum untuk A1066 Gr.70

Used in the most demanding bridge and structural applications: main girder flanges on record-span bridges, arch rib plates, suspension bridge stiffening truss chords, and heavy industrial crane runway girders. A1066 Gr.70 does not qualify for any H8 reduced preheat, so full Category C preheat must be applied regardless of consumable certification. This makes preheat management the primary production consideration for heavy-section joints where flange thicknesses of 2-4" are common. Fabrication bid costs for A1066 Gr.70 components must account for the full Category C preheat time in their labor estimates — typically 45-90 minutes per joint on plate over 2". Unlike Grades 50 and 60/65, there is no consumable-based path to reduce preheat duration on Gr.70 joints. Bridge fabrication shops working with this grade maintain dedicated preheat logs and temperature monitoring records for every CJP and PJP weld as part of their quality management system.

Mengapa Preheat Penting pada over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Preheat Kategori C untuk A1066 Gr.70

Kategori C pada Tabel 5.11 berlaku untuk baja kekuatan tinggi di mana kombinasi kemampuan pengerasan dan tegangan sisa memerlukan preheat tinggi. Untuk A1066 Gr.70 pada over 2-1/2", preheat minimum 300°F memperlambat laju pendinginan las untuk mencegah pembentukan martensit rentan retak di zona terpengaruh panas.

Baja Lain dengan SMAW (low-hydrogen) pada over 2-1/2"

BajaKategoriPreheat
A36B225°F (110°C)
A53 Gr.BB225°F (110°C)
A106 Gr.BB225°F (110°C)
A633 Gr.EC300°F (150°C)

A1066 Gr.70 dengan SMAW (low-hydrogen)

Coba Kombinasi Berbeda

Gunakan kalkulator preheat interaktif untuk mencari kombinasi baja, proses, dan ketebalan dari D1.1:2025 Tabel 5.11.

Berapa preheat minimum untuk A1066 Gr.70 dengan SMAW-LH pada over 2-1/2"?
Untuk A1066 Gr.70 dilas dengan SMAW (low-hydrogen) pada ketebalan over 2-1/2", suhu preheat minimum adalah 300°F (150°C) sesuai AWS D1.1:2025 Tabel 5.11, Kategori C.
Kategori Tabel 5.11 apa yang berlaku untuk A1066 Gr.70 dengan SMAW-LH?
A1066 Gr.70 dilas dengan SMAW (low-hydrogen) termasuk Kategori C di AWS D1.1:2025 Tabel 5.11. Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah (baja kekuatan tinggi). Pada ketebalan over 2-1/2", kategori ini memerlukan preheat minimum 300°F (150°C).
Mengapa preheat 300°F untuk A1066 Gr.70 pada over 2-1/2"?
Preheat 300°F untuk A1066 Gr.70 pada over 2-1/2" dengan SMAW (low-hydrogen) mencerminkan kombinasi kemampuan pengerasan baja dan peningkatan pengekangan pada ketebalan ini.

Data referensi D1.1:2025. Tidak berafiliasi dengan AWS.