AWS D1.1:2025 · Tabel 5.11 · Kategori A

Preheat A106 Gr.B untuk SMAW (non-low-hydrogen) — over 2-1/2"

Suhu pemanasan awal dan antar lajur minimum untuk A106 Gr.B dilas dengan SMAW (non-low-hydrogen) pada ketebalan over 2-1/2", sesuai AWS D1.1:2025 Tabel 5.11.

Berdasarkan AWS D1.1:2025 Tabel 5.11 — setiap nilai dilacak ke pasal.

Suhu Minimum Pemanasan Awal dan Antar Lajur
300°F / 150°C
Kategori A
Proses SMAW bukan hidrogen rendah
AWS D1.1:2025 Tabel 5.11, §5.7
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

On pipe joints, non-low-hydrogen SMAW root passes with E6010 use the keyhole technique to ensure complete penetration. Pipe rotation (roll welding) is preferred when practical; fixed-position welding requires 5G or 6G qualified procedures. The cellulosic coating generates significant spatter, so adjacent base metal should be protected with anti-spatter compound.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

Mengapa Preheat Ini untuk A106 Gr.B dengan SMAW

Seamless pipe rated for high-temperature service up to 750°F. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Aplikasi Umum untuk A106 Gr.B

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

Mengapa Preheat Penting pada over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Baja Lain dengan SMAW (non-low-hydrogen) pada over 2-1/2"

BajaKategoriPreheat
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

A106 Gr.B dengan SMAW (non-low-hydrogen)

Coba Kombinasi Berbeda

Gunakan kalkulator preheat interaktif untuk mencari kombinasi baja, proses, dan ketebalan dari D1.1:2025 Tabel 5.11.

Berapa preheat minimum untuk A106 Gr.B dengan SMAW pada over 2-1/2"?
Untuk A106 Gr.B dilas dengan SMAW (non-low-hydrogen) pada ketebalan over 2-1/2", suhu preheat minimum adalah 300°F (150°C) sesuai AWS D1.1:2025 Tabel 5.11, Kategori A.
Kategori Tabel 5.11 apa yang berlaku untuk A106 Gr.B dengan SMAW?
A106 Gr.B dilas dengan SMAW (non-low-hydrogen) termasuk Kategori A di AWS D1.1:2025 Tabel 5.11. Proses SMAW bukan hidrogen rendah. Pada ketebalan over 2-1/2", kategori ini memerlukan preheat minimum 300°F (150°C).
Mengapa preheat 300°F untuk A106 Gr.B pada over 2-1/2"?
Preheat 300°F untuk A106 Gr.B pada over 2-1/2" dengan SMAW (non-low-hydrogen) mencerminkan kombinasi kemampuan pengerasan baja dan peningkatan pengekangan pada ketebalan ini.

Data referensi D1.1:2025. Tidak berafiliasi dengan AWS.