AWS D1.1:2025 · Tabel 5.11 · Kategori B

Preheat A106 Gr.B untuk SMAW (low-hydrogen) — over 2-1/2"

Suhu pemanasan awal dan antar lajur minimum untuk A106 Gr.B dilas dengan SMAW (low-hydrogen) pada ketebalan over 2-1/2", sesuai AWS D1.1:2025 Tabel 5.11.

Berdasarkan AWS D1.1:2025 Tabel 5.11 — setiap nilai dilacak ke pasal.

Suhu Minimum Pemanasan Awal dan Antar Lajur
225°F / 110°C
Kategori B
Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah
AWS D1.1:2025 Tabel 5.11, §5.7
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For pipe butt joints, E7018 fill and cap passes follow the E6010 root. Vertical-down technique is not permitted with low-hydrogen electrodes. Interpass cleaning requires chipping and wire brushing between every pass to remove slag inclusions. Restart craters should be ground to sound metal before striking a new arc.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

Mengapa Preheat Ini untuk A106 Gr.B dengan SMAW-LH

Seamless pipe rated for high-temperature service up to 750°F. With low-hydrogen SMAW-LH, this combination falls under Category B rather than Category A, reflecting the lower hydrogen potential of the consumable. The 225°F minimum preheat is lower than what non-low-hydrogen SMAW would require at the same thickness. Low-hydrogen electrodes and inherently low-hydrogen wire processes reduce the driving force for hydrogen-induced cracking in the heat-affected zone.

Aplikasi Umum untuk A106 Gr.B

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

Mengapa Preheat Penting pada over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Baja Lain dengan SMAW (low-hydrogen) pada over 2-1/2"

BajaKategoriPreheat
A36B225°F (110°C)
A633 Gr.EC300°F (150°C)
A709 HPS70WC300°F (150°C)
A710 Gr.AC300°F (150°C)

A106 Gr.B dengan SMAW (low-hydrogen)

Coba Kombinasi Berbeda

Gunakan kalkulator preheat interaktif untuk mencari kombinasi baja, proses, dan ketebalan dari D1.1:2025 Tabel 5.11.

Berapa preheat minimum untuk A106 Gr.B dengan SMAW-LH pada over 2-1/2"?
Untuk A106 Gr.B dilas dengan SMAW (low-hydrogen) pada ketebalan over 2-1/2", suhu preheat minimum adalah 225°F (110°C) sesuai AWS D1.1:2025 Tabel 5.11, Kategori B.
Kategori Tabel 5.11 apa yang berlaku untuk A106 Gr.B dengan SMAW-LH?
A106 Gr.B dilas dengan SMAW (low-hydrogen) termasuk Kategori B di AWS D1.1:2025 Tabel 5.11. Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah. Pada ketebalan over 2-1/2", kategori ini memerlukan preheat minimum 225°F (110°C).
Mengapa preheat 225°F untuk A106 Gr.B pada over 2-1/2"?
Preheat 225°F untuk A106 Gr.B pada over 2-1/2" dengan SMAW (low-hydrogen) mencerminkan kombinasi kemampuan pengerasan baja dan peningkatan pengekangan pada ketebalan ini.

Data referensi D1.1:2025. Tidak berafiliasi dengan AWS.