AWS D1.1:2025 · Tabel 5.11 · Kategori B

Preheat A106 Gr.B untuk GMAW — 1-1/2" to 2-1/2"

Suhu pemanasan awal dan antar lajur minimum untuk A106 Gr.B dilas dengan GMAW pada ketebalan 1-1/2" to 2-1/2", sesuai AWS D1.1:2025 Tabel 5.11.

Berdasarkan AWS D1.1:2025 Tabel 5.11 — setiap nilai dilacak ke pasal.

Suhu Minimum Pemanasan Awal dan Antar Lajur
150°F / 65°C
Kategori B
Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah
AWS D1.1:2025 Tabel 5.11, §5.7
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

GMAW (Gas Metal Arc Welding)

GMAW (MIG) feeds continuous solid wire with shielding gas — an inherently low-hydrogen process assigned to Category B in Table 5.11.

GMAW on pipe requires specialized gun angles and travel speed control for circumferential joints. Pulsed GMAW is increasingly popular for pipe root passes as an alternative to SMAW. The absence of slag between passes eliminates inter-pass cleaning time, significantly improving productivity on multi-pass pipe joints.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

Mengapa Preheat Ini untuk A106 Gr.B dengan GMAW

Seamless pipe rated for high-temperature service up to 750°F. With low-hydrogen GMAW, this combination falls under Category B rather than Category A, reflecting the lower hydrogen potential of the consumable. The 150°F minimum preheat is lower than what non-low-hydrogen SMAW would require at the same thickness. Low-hydrogen electrodes and inherently low-hydrogen wire processes reduce the driving force for hydrogen-induced cracking in the heat-affected zone.

Aplikasi Umum untuk A106 Gr.B

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

Mengapa Preheat Penting pada 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Baja Lain dengan GMAW pada 1-1/2" to 2-1/2"

BajaKategoriPreheat
A36B150°F (65°C)
A633 Gr.EC225°F (110°C)
A709 HPS70WC225°F (110°C)
A710 Gr.AC225°F (110°C)

Coba Kombinasi Berbeda

Gunakan kalkulator preheat interaktif untuk mencari kombinasi baja, proses, dan ketebalan dari D1.1:2025 Tabel 5.11.

Berapa preheat minimum untuk A106 Gr.B dengan GMAW pada 1-1/2" to 2-1/2"?
Untuk A106 Gr.B dilas dengan GMAW pada ketebalan 1-1/2" to 2-1/2", suhu preheat minimum adalah 150°F (65°C) sesuai AWS D1.1:2025 Tabel 5.11, Kategori B.
Kategori Tabel 5.11 apa yang berlaku untuk A106 Gr.B dengan GMAW?
A106 Gr.B dilas dengan GMAW termasuk Kategori B di AWS D1.1:2025 Tabel 5.11. Proses SMAW, SAW, GMAW atau FCAW hidrogen rendah. Pada ketebalan 1-1/2" to 2-1/2", kategori ini memerlukan preheat minimum 150°F (65°C).
Mengapa preheat 150°F untuk A106 Gr.B pada 1-1/2" to 2-1/2"?
Preheat 150°F untuk A106 Gr.B pada 1-1/2" to 2-1/2" dengan GMAW mencerminkan kombinasi kemampuan pengerasan baja dan peningkatan pengekangan pada ketebalan ini.

Data referensi D1.1:2025. Tidak berafiliasi dengan AWS.