AASHTO/AWS D1.5:2025 · Tabel 12.6/12.7 · Fraktur Kritis · H4

Preheat M270M HPS345W — H4, High HI, 20–40 mm: 150°F

Persyaratan preheat fraktur kritis untuk M270M HPS345W / M270 HPS50W pada ketebalan 20–40 mm (3/4–1½ in) dengan penunjukan hidrogen H4, sesuai AASHTO/AWS D1.5:2025, Kode Pengelasan Jembatan.

Berdasarkan AWS D1.5:2025 — setiap nilai dilacak ke pasal.

Preheat dan Interpass Minimum Fraktur Kritis
150°F / 70°C
Hidrogen H4 · masukan panas > 2.8 kJ/mm · ketebalan 20–40 mm (3/4–1½ in)
AASHTO/AWS D1.5M/D1.5:2025 Tabel 12.6/12.7
Penunjukan H4: bahan habis pakai mengendapkan ≤ 4 mL/100g hidrogen difusibel sesuai AWS A4.3. Hidrogen lebih rendah = preheat lebih rendah.
Alat referensi. Verifikasi terhadap edisi yang berlaku dan WPS yang disetujui Insinyur.

M270M HPS345W / M270 HPS50W

AASHTO M270M HPS345W (M270 HPS50W) is a high-performance weathering bridge steel with enhanced weldability through controlled chemistry — 0.11% max carbon, 0.006% max sulfur with calcium treatment for inclusion shape control. Developed under FHWA-funded research to eliminate the lamellar tearing and inconsistent toughness problems of earlier weathering steel bridge designs. The lower carbon equivalent compared to conventional Gr.345W reduces cracking sensitivity at flange splices. NFC preheat per Table 6.3 Group 1; FC per Tables 12.6/12.7.

Memahami Preheat FC untuk M270M HPS345W / M270 HPS50W

High-performance weathering 345 MPa steel with enhanced weldability. Under D1.5 fracture-critical requirements (Clause 12), the combination of H4 hydrogen designation and this heat input band requires 150°F minimum preheat at 20–40 mm (3/4–1½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Di Mana M270M HPS345W / M270 HPS50W Digunakan

Preferred over conventional Gr.345W for new unpainted bridge construction. The HPS designation indicates FHWA-developed chemistry with 0.11% max carbon and controlled sulfur for enhanced weldability and lamellar tearing resistance. Flange splice CJP welds benefit from the lower carbon equivalent, reducing reject rates during cold-weather bridge fabrication. Material cost premium over standard Gr.345W is typically 15–25% per ton but eliminates weldability-related rework.

Kontrol Hidrogen H4 untuk M270M HPS345W / M270 HPS50W

HPS345W (HPS50W) already has inherently low carbon equivalent due to HPS chemistry control. Combined with H4 consumables, the preheat requirement drops to the lowest tier in Tables 12.6/12.7 — frequently 20–30°F lower than conventional 345W, compounding the weldability advantage of HPS chemistry with optimized hydrogen control.

Mengapa Preheat Penting pada 20–40 mm (3/4–1½ in)

Material from 20 to 40 mm (3/4 to 1-1/2 in) includes many girder web plates, splice plates, and bearing stiffener plates. Preheat increases to 20°C (70°F) for Group 1 and 50°C (125°F) for Group 2 under Table 6.3. The thicker section slows hydrogen diffusion, requiring higher preheat to maintain safe cooling rates.

M270M HPS345W / M270 HPS50W pada 20–40 mm (3/4–1½ in)

At 20–40 mm, HPS345W (HPS50W) appears in splice plates and web plates for new unpainted bridge construction. The calcium-treated, inclusion-shape-controlled chemistry virtually eliminates lamellar tearing at through-thickness-loaded connections — a critical advantage for corner joints at bearing stiffener-to-flange connections where Z-direction tensile stresses develop during welding contraction.

Bahan Habis Pakai Bersertifikat H4 untuk Pengelasan FC Jembatan

Penunjukan tambahan H4 menyertifikasi bahwa bahan habis pakai mengendapkan tidak lebih dari 4 mL hidrogen difusibel per 100g logam yang diendapkan. Untuk fraktur kritis M270M HPS345W / M270 HPS50W pada ketebalan 20–40 mm (3/4–1½ in) dengan masukan panas > 2.8 kJ/mm, bahan habis pakai H4 mencapai preheat terendah 150°F (70°C) di tabel FC.

Baja Jembatan Lain pada H4 > 2.8 kJ/mm · 20–40 mm (3/4–1½ in)

BajaTabelPreheat
M270M Gr.250 / M270 Gr.36A100°F (40°C)
M270M Gr.345 / M270 Gr.50A100°F (40°C)
M270M Gr.345S / M270 Gr.50SA100°F (40°C)
M270M Gr.345W / M270 Gr.50WB150°F (70°C)

Coba Kombinasi Berbeda

Gunakan Kalkulator Preheat Jembatan D1.5 untuk mencari baja AASHTO M270, tingkat hidrogen, dan kombinasi masukan panas. Lihat juga Kalkulator Preheat D1.1 untuk baja struktural.

Berapa preheat FC untuk M270M HPS345W / M270 HPS50W dengan H4 pada 20–40 mm (3/4–1½ in)?
Untuk fraktur kritis M270M HPS345W / M270 HPS50W dilas dengan bahan habis pakai bertanda H4 pada ketebalan 20–40 mm (3/4–1½ in) dan masukan panas > 2.8 kJ/mm, preheat minimum adalah 150°F (70°C) sesuai D1.5 Tabel 12.6/12.7.
Apa perbedaan antara preheat FC dan NFC untuk M270M HPS345W / M270 HPS50W?
Preheat non-fraktur kritis (Tabel 6.3) adalah pencarian sederhana berdasarkan ketebalan. Preheat fraktur kritis (Tabel 12.4–12.8) menambahkan tingkat hidrogen dan masukan panas sebagai variabel, biasanya memerlukan preheat lebih tinggi.
Bagaimana masukan panas mempengaruhi preheat FC M270M HPS345W / M270 HPS50W?
Masukan panas lebih tinggi berarti laju pendinginan lebih lambat, memberikan hidrogen lebih banyak waktu untuk berdifusi keluar dari zona las. Pada > 2.8 kJ/mm, preheat 150°F menyeimbangkan tingkat hidrogen dan laju pendinginan.
Why does Group 2 need higher preheat than Group 1 at this thickness?
Group 2 steels (HPS485W, HPS690W) have higher hardenability from their increased alloy content, forming harder microstructures on cooling. The 50°C (125°F) minimum versus Group 1’s 20°C (70°F) compensates for the greater cracking susceptibility of these higher-strength grades.

Data referensi D1.5:2025. Tidak berafiliasi dengan AWS atau AASHTO.