Precalentamiento HPS485W — H16, Lo, 20–40 mm: 250°F
Requisito de precalentamiento de fractura crítica para M270M HPS485W / M270 HPS70W en espesor 20–40 mm (3/4–1½ in) con designación de hidrógeno H16, según AASHTO/AWS D1.5:2025, el Código de Soldadura de Puentes.
Basado en AWS D1.5:2025 — cada valor trazado a la cláusula.
M270M HPS485W / M270 HPS70W
AASHTO M270M HPS485W (M270 HPS70W) is a high-performance weathering steel with 485 MPa (70 ksi) yield, used in long-span bridge girder flanges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate up to 100 mm (4 in) thick. The high strength level places it in NFC Group 2 (Table 6.3) with higher minimum preheat than Group 1. FC preheat follows Tables 12.6/12.7 alongside the 345W grades but at higher temperatures reflecting the increased hardenability. Maximum interpass per Table 6.4 is 230°C (450°F) to protect the Q&T microstructure.
Entendiendo el Precalentamiento FC para M270M HPS485W / M270 HPS70W
High-performance 485 MPa (70 ksi) weathering bridge steel. Under D1.5 fracture-critical requirements (Clause 12), the combination of H16 hydrogen designation and this heat input band requires 250°F minimum preheat at 20–40 mm (3/4–1½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
Dónde se Usa M270M HPS485W / M270 HPS70W
Used in long-span bridge main girder flanges, cable-stayed bridge edge girders, and heavily loaded interchange ramp girders where weight reduction is critical. Enables 20–30% weight savings versus Gr.345 designs, allowing shallower girder sections that reduce embankment costs. Flange thickness often exceeds 50 mm (2 in), making preheat and interpass control critical at every CJP splice. Fabricators must use dual-readout temperature monitoring to ensure joints stay within the qualified range between minimum preheat and maximum interpass.
Control de Hidrógeno H16 para M270M HPS485W / M270 HPS70W
HPS485W (HPS70W) at H16 represents the highest-risk FC scenario for this grade — the combination of high strength, high hardenability, and high hydrogen demands the maximum preheat in Tables 12.6/12.7. Production scheduling must account for extended preheat soak times at every joint. Many fabricators refuse H16 on HPS485W, requiring H4 or H8 in their shop standards.
Por qué el Precalentamiento Importa en 20–40 mm (3/4–1½ in)
Material from 20 to 40 mm (3/4 to 1-1/2 in) includes many girder web plates, splice plates, and bearing stiffener plates. Preheat increases to 20°C (70°F) for Group 1 and 50°C (125°F) for Group 2 under Table 6.3. The thicker section slows hydrogen diffusion, requiring higher preheat to maintain safe cooling rates.
M270M HPS485W / M270 HPS70W en 20–40 mm (3/4–1½ in)
At 20–40 mm, HPS485W (HPS70W) serves as the primary flange material for long-span bridge girders where weight reduction is the design driver. The 70 ksi yield enables 20–30% thinner flanges versus Gr.345 designs, reducing dead load and allowing shallower girder depths that save embankment costs. CJP flange splices at this thickness require precise heat input control to stay within the FC table parameters.
Mayor Precalentamiento con Designación H16
Los consumibles H16 permiten hasta 16 mL de hidrógeno difusible por 100g — el nivel más alto permitido para soldadura FC de puentes. En 20–40 mm (3/4–1½ in) con aporte térmico 1.2–2.0 kJ/mm, el precalentamiento de 250°F (120°C) compensa el mayor potencial de hidrógeno.
Otros Aceros de Puente en H16 1.2–2.0 kJ/mm · 20–40 mm (3/4–1½ in)
| Acero | Tabla | Precalentamiento |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 200°F (100°C) |
| M270M Gr.345 / M270 Gr.50 | A | 200°F (100°C) |
| M270M Gr.345S / M270 Gr.50S | A | 200°F (100°C) |
| M270M Gr.345W / M270 Gr.50W | B | 250°F (120°C) |
M270M HPS485W / M270 HPS70W en H16 1.2–2.0 kJ/mm
Prueba Diferentes Combinaciones
Usa la Calculadora de Precalentamiento D1.5 para Puentes para consultar cualquier acero AASHTO M270, nivel de hidrógeno y combinación de aporte térmico. También consulta la Calculadora de Precalentamiento D1.1 para acero estructural.
Guías Relacionadas
Datos de referencia D1.5:2025. Sin afiliación con AWS o AASHTO.