Precalentamiento M270M HPS345W — H4, High HI, > 60 mm: 300°F
Requisito de precalentamiento de fractura crítica para M270M HPS345W / M270 HPS50W en espesor > 60 mm (> 2½ in) con designación de hidrógeno H4, según AASHTO/AWS D1.5:2025, el Código de Soldadura de Puentes.
Basado en AWS D1.5:2025 — cada valor trazado a la cláusula.
M270M HPS345W / M270 HPS50W
AASHTO M270M HPS345W (M270 HPS50W) is a high-performance weathering bridge steel with enhanced weldability through controlled chemistry — 0.11% max carbon, 0.006% max sulfur with calcium treatment for inclusion shape control. Developed under FHWA-funded research to eliminate the lamellar tearing and inconsistent toughness problems of earlier weathering steel bridge designs. The lower carbon equivalent compared to conventional Gr.345W reduces cracking sensitivity at flange splices. NFC preheat per Table 6.3 Group 1; FC per Tables 12.6/12.7.
Entendiendo el Precalentamiento FC para M270M HPS345W / M270 HPS50W
High-performance weathering 345 MPa steel with enhanced weldability. Under D1.5 fracture-critical requirements (Clause 12), the combination of H4 hydrogen designation and this heat input band requires 300°F minimum preheat at > 60 mm (> 2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
Dónde se Usa M270M HPS345W / M270 HPS50W
Preferred over conventional Gr.345W for new unpainted bridge construction. The HPS designation indicates FHWA-developed chemistry with 0.11% max carbon and controlled sulfur for enhanced weldability and lamellar tearing resistance. Flange splice CJP welds benefit from the lower carbon equivalent, reducing reject rates during cold-weather bridge fabrication. Material cost premium over standard Gr.345W is typically 15–25% per ton but eliminates weldability-related rework.
Control de Hidrógeno H4 para M270M HPS345W / M270 HPS50W
HPS345W (HPS50W) already has inherently low carbon equivalent due to HPS chemistry control. Combined with H4 consumables, the preheat requirement drops to the lowest tier in Tables 12.6/12.7 — frequently 20–30°F lower than conventional 345W, compounding the weldability advantage of HPS chemistry with optimized hydrogen control.
Por qué el Precalentamiento Importa en > 60 mm (> 2½ in)
Material over 65 mm (2-1/2 in) includes the heaviest bridge girder flanges and box-section walls. Table 6.3 requires 110°C (225°F) for both groups at this thickness. Extended preheat soak time is necessary to achieve uniform through-thickness temperature. FC preheat for the heaviest sections reaches 180–200°C (350–400°F) at the H16 hydrogen level.
M270M HPS345W / M270 HPS50W en > 60 mm (> 2½ in)
HPS345W (HPS50W) above 65 mm is the preferred material for heavy unpainted bridge flanges replacing conventional 345W. The sulfur control (0.006% max) and calcium treatment ensure clean steel with minimal through-thickness anisotropy. At this thickness, the weldability advantage is most pronounced — conventional 345W at 65+ mm required expensive preheat and post-weld hydrogen bake-out procedures that HPS chemistry largely eliminates.
Consumibles Certificados H4 para Soldadura FC de Puentes
El designador suplementario H4 certifica que el consumible deposita no más de 4 mL de hidrógeno difusible por 100g de metal depositado. Para fractura crítica M270M HPS345W / M270 HPS50W en espesor > 60 mm (> 2½ in) con aporte térmico > 2.8 kJ/mm, los consumibles H4 logran el menor precalentamiento de 300°F (150°C) en las tablas FC.
Otros Aceros de Puente en H4 > 2.8 kJ/mm · > 60 mm (> 2½ in)
| Acero | Tabla | Precalentamiento |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 250°F (120°C) |
| M270M Gr.345 / M270 Gr.50 | A | 250°F (120°C) |
| M270M Gr.345S / M270 Gr.50S | A | 250°F (120°C) |
| M270M Gr.345W / M270 Gr.50W | B | 300°F (150°C) |
M270M HPS345W / M270 HPS50W en H4 > 2.8 kJ/mm
Prueba Diferentes Combinaciones
Usa la Calculadora de Precalentamiento D1.5 para Puentes para consultar cualquier acero AASHTO M270, nivel de hidrógeno y combinación de aporte térmico. También consulta la Calculadora de Precalentamiento D1.1 para acero estructural.
Guías Relacionadas
Datos de referencia D1.5:2025. Sin afiliación con AWS o AASHTO.