AWS D1.1:2025 · Tabelle 5.11 · Kategorie B

A913 Gr.50/60/65 Vorwärmung für SMAW (low-hydrogen) — over 2-1/2"

Mindestvorwärm- und Zwischenlagentemperatur für A913 Gr.50/60/65 geschweißt mit SMAW (low-hydrogen) bei over 2-1/2" Dicke, gemäß AWS D1.1:2025 Tabelle 5.11.

Basierend auf AWS D1.1:2025 Tabelle 5.11 — jeder Wert bis zur Klausel zurückverfolgt.

Mindest-Vorwärm- und Zwischenlagentemperatur
225°F / 110°C
Kategorie B
Niedrigwasserstoff SMAW-, SAW-, GMAW- oder FCAW-Verfahren
AWS D1.1:2025 Tabelle 5.11, §5.7
Referenzwerkzeug. Gegen projektanwendbare Ausgabe und von Ingenieur genehmigte WPS prüfen.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A913 Gr.50/60/65

ASTM A913 Grades 50 (50 ksi yield), 60 (60 ksi yield), and 65 (65 ksi yield) are quenched-and-self-tempered (QST) structural shapes produced by thermo-mechanical controlled processing (TMCP) — an in-line water quench immediately after the final rolling pass, followed by self-tempering from the core heat. This produces a fine-grained bainitic/ferritic microstructure throughout the full cross-section with carbon content typically 0.10-0.16% and CE-IIW of 0.35-0.42. Standard low-hydrogen processes use Category B; H8-certified consumables qualify for the reduced Category D (32°F all thicknesses), reflecting the inherent hydrogen cracking resistance of the TMCP microstructure. Available exclusively as W-shapes (primarily W14 heavy column sections), A913 is not produced as plate or other forms. The QST process eliminates the need for separate mill heat treatment, providing consistent through-thickness properties.

Warum Diese Vorwärmung für A913 Gr.50/60/65 mit SMAW-LH

TMCP structural shapes for seismic frames with H8-eligible reduced preheat. This steel is prequalified only with low-hydrogen processes under Table 5.11, which is why it appears in Category B but not Category A. The 225°F minimum preheat with SMAW-LH balances the steel's strength level and carbon equivalent against the controlled hydrogen input from the consumable. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Typische Anwendungen für A913 Gr.50/60/65

Specified for seismic moment frame columns, high-rise building corner columns, transfer girder bearing seats, heavy truss chords, stadium cantilever support columns, and parking garage moment frame members. A913 TMCP shapes eliminate the need for post-rolling heat treatment, providing consistent through-thickness properties from flange tip to web center. Column splice CJP welds and beam-to-column continuity plate fillet welds are the critical weld joints. Available in W14 sections from W14x132 through W14x730, these shapes are the backbone of seismic column design in high-rise construction. The TMCP process creates a fine-grained microstructure throughout the full cross-section, unlike conventional heat-treated shapes that may have property gradients. The H8 path to Category D (32°F all thicknesses) offers significant fabrication cost savings on heavy column splices that would otherwise require 150-225°F preheat under Category B. Column flange thicknesses on W14x455 and heavier sections exceed 3".

Warum Vorwärmung bei over 2-1/2" Wichtig ist

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Andere Stähle mit SMAW (low-hydrogen) bei over 2-1/2"

StahlKategorieVorwärmung
A36B225°F (110°C)
A633 Gr.EC300°F (150°C)
A709 HPS70WC300°F (150°C)
A710 Gr.AC300°F (150°C)

A913 Gr.50/60/65 mit SMAW (low-hydrogen)

Verschiedene Kombinationen Ausprobieren

Verwenden Sie den interaktiven Vorwärmrechner für jede Stahl-, Verfahrens- und Dickenkombination aus D1.1:2025 Tabelle 5.11.

Was ist die Mindestvorwärmung für A913 Gr.50/60/65 mit SMAW-LH bei over 2-1/2"?
Für A913 Gr.50/60/65 geschweißt mit SMAW (low-hydrogen) bei over 2-1/2" Dicke beträgt die Mindestvorwärmtemperatur 225°F (110°C) gemäß AWS D1.1:2025 Tabelle 5.11, Kategorie B.
Welche Kategorie der Tabelle 5.11 gilt für A913 Gr.50/60/65 mit SMAW-LH?
A913 Gr.50/60/65 geschweißt mit SMAW (low-hydrogen) fällt unter Kategorie B in AWS D1.1:2025 Tabelle 5.11. Niedrigwasserstoff SMAW-, SAW-, GMAW- oder FCAW-Verfahren. Bei over 2-1/2" Dicke erfordert diese Kategorie eine Mindestvorwärmung von 225°F (110°C).
Warum ist die Vorwärmung 225°F für A913 Gr.50/60/65 bei over 2-1/2"?
Die 225°F Vorwärmung für A913 Gr.50/60/65 bei over 2-1/2" mit SMAW (low-hydrogen) spiegelt die Kombination aus Härtbarkeit des Stahls und erhöhter Einspannung bei dieser Dicke wider.