Preheat Heat Input Fillet Weld Size Deposition Rate Carbon Equivalent
AWS D1.1:2025 · Table 5.11 · Category B

A709 HPS50W Preheat for FCAW — 1-1/2" to 2-1/2"

Minimum preheat and interpass temperature for A709 HPS50W welded with FCAW at 1-1/2" to 2-1/2" thickness, per AWS D1.1:2025 Table 5.11.

Minimum Preheat & Interpass Temperature
150°F / 65°C
Category B
Low-hydrogen SMAW, SAW, GMAW, or FCAW process
AWS D1.1:2025 Table 5.11, §5.7
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

FCAW (Flux Cored Arc Welding)

FCAW uses tubular flux-cored wire, available gas-shielded (E71T-1) or self-shielded (E71T-8) for field work. Category B in Table 5.11.

E71T-1 gas-shielded wire is the workhorse for structural steel erection fillet welds. Self-shielded E71T-8 is preferred for field welding where wind makes gas shielding unreliable. Deposition rates run 8-12 lb/hr depending on wire diameter and position. The flux core provides a protective slag that supports the puddle in vertical-up and overhead positions.

A709 HPS50W

ASTM A709 HPS50W is a high-performance weathering steel (50 ksi yield, 70 ksi minimum tensile) developed specifically for unpainted bridge construction. The HPS designation indicates enhanced weldability through lower carbon (0.11% max), controlled sulfur (0.006% max with calcium treatment), and copper-nickel-chromium alloying for atmospheric corrosion resistance. These chemistry controls reduce the CE-IIW to approximately 0.38-0.42, well below conventional weathering steels. It falls under Category B in Table 5.11. The FHWA-funded development program that created HPS grades (starting in the 1990s) aimed to eliminate the weldability problems, lamellar tearing, and inconsistent toughness that plagued earlier weathering steel bridge designs. HPS50W has largely replaced conventional A709 Gr.50W in new unpainted bridge designs.

Why This Preheat for A709 HPS50W with FCAW

High-performance weathering bridge steel with enhanced weldability at 50 ksi. This steel is prequalified only with low-hydrogen processes under Table 5.11, which is why it appears in Category B but not Category A. The 150°F minimum preheat with FCAW balances the steel's strength level and carbon equivalent against the controlled hydrogen input from the consumable. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Typical Applications for A709 HPS50W

Deployed in unpainted bridge plate girders across humid or coastal environments, curved girders on interchange ramps, signature pedestrian bridges in architectural applications, and rural highway bridges where lifecycle paint costs exceed the HPS premium. The enhanced weldability of HPS50W reduces fabrication risk at flange splices and allows wider groove angles with reduced risk of lamellar tearing in thick flange plates through controlled sulfur and inclusion shape control via calcium treatment. The chemistry control (0.11% max carbon, controlled sulfur at 0.006% max) differentiates HPS from conventional weathering grades. Material cost premium over standard A709 Gr.50W is typically 15-25% per ton but eliminates lifetime repainting cycles estimated at $15-25 per square foot every 20-25 years. The lower CE-IIW of HPS50W compared to conventional weathering grades means it welds with less preheat sensitivity, reducing reject rates on thick flange CJP splices during cold-weather bridge fabrication.

Why Preheat Matters at 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Other Steels with FCAW at 1-1/2" to 2-1/2"

SteelCategoryPreheat
A36B150°F (65°C)
A633 Gr.EC225°F (110°C)
A709 HPS70WC225°F (110°C)
A710 Gr.AC225°F (110°C)

Try Different Combinations

Use the interactive preheat calculator to look up any steel, process, and thickness combination from D1.1:2025 Table 5.11.

What is the minimum preheat for A709 HPS50W with FCAW at 1-1/2" to 2-1/2"?
For A709 HPS50W welded with FCAW at 1-1/2" to 2-1/2" thickness, the minimum preheat temperature is 150°F (65°C) per AWS D1.1:2025 Table 5.11, Category B. This is also the minimum interpass temperature — the joint must not cool below 150°F between passes.
What Table 5.11 category applies to A709 HPS50W with FCAW?
A709 HPS50W welded with FCAW falls under Category B in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process. At 1-1/2" to 2-1/2" thickness, this category requires a minimum preheat of 150°F (65°C).
Why is preheat 150°F for A709 HPS50W at 1-1/2" to 2-1/2"?
The 150°F preheat for A709 HPS50W at 1-1/2" to 2-1/2" with FCAW reflects the combination of the steel's hardenability and the increased restraint at this thickness. Higher preheat slows the cooling rate in the heat-affected zone, giving diffusible hydrogen more time to escape before the steel transforms to a crack-susceptible microstructure.
What happens if I skip preheat on thick plate?
Without adequate preheat on material in the 1-1/2” to 2-1/2” range, the weld HAZ cools rapidly, trapping diffusible hydrogen in a hardened microstructure. This creates conditions for hydrogen-induced cracking (also called cold cracking or delayed cracking), which may not appear until hours or days after welding. Table 5.11 preheat minimums are set to prevent this failure mode.