AWS D1.1:2025 · Tablo 5.11 · Kategori A

A106 Gr.B için SMAW (non-low-hydrogen) Ön Isıtma — 3/4" to 1-1/2"

AWS D1.1:2025 Tablo 5.11'e göre 3/4" to 1-1/2" kalınlıkta SMAW (non-low-hydrogen) ile kaynaklanan A106 Gr.B için minimum ön ısıtma ve pasolar arası sıcaklık.

AWS D1.1:2025 Tablo 5.11 tabanlı — her değer maddeye kadar izlenmiştir.

Minimum Ön Isıtma ve Pasolar Arası Sıcaklık
150°F / 65°C
Kategori A
Düşük hidrojen olmayan SMAW prosesi
AWS D1.1:2025 Tablo 5.11, §5.7
Referans aracı. Proje uygulanabilir sürüm ve Mühendis onaylı KPŞ ile doğrulayın.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

On pipe joints, non-low-hydrogen SMAW root passes with E6010 use the keyhole technique to ensure complete penetration. Pipe rotation (roll welding) is preferred when practical; fixed-position welding requires 5G or 6G qualified procedures. The cellulosic coating generates significant spatter, so adjacent base metal should be protected with anti-spatter compound.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

SMAW ile A106 Gr.B için Bu Ön Isıtma Neden

Seamless pipe rated for high-temperature service up to 750°F. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 150°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

A106 Gr.B için Tipik Uygulamalar

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

3/4" to 1-1/2"'de Ön Isıtma Neden Önemlidir

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

3/4" to 1-1/2"'de SMAW (non-low-hydrogen) ile Diğer Çelikler

ÇelikKategoriÖn Isıtma
A36A150°F (65°C)
A53 Gr.BA150°F (65°C)

SMAW (non-low-hydrogen) ile A106 Gr.B

Farklı Kombinasyonları Dene

D1.1:2025 Tablo 5.11'den herhangi bir çelik, proses ve kalınlık kombinasyonunu aramak için interaktif ön ısıtma hesap makinesini kullanın.

3/4" to 1-1/2"'de SMAW ile A106 Gr.B için minimum ön ısıtma nedir?
3/4" to 1-1/2" kalınlıkta SMAW (non-low-hydrogen) ile kaynaklanan A106 Gr.B için minimum ön ısıtma sıcaklığı AWS D1.1:2025 Tablo 5.11, Kategori A'e göre 150°F (65°C)'dir.
SMAW ile A106 Gr.B için hangi kategori geçerlidir?
SMAW (non-low-hydrogen) ile kaynaklanan A106 Gr.B, AWS D1.1:2025 Tablo 5.11'de Kategori A altına girer. Düşük hidrojen olmayan SMAW prosesi. 3/4" to 1-1/2" kalınlıkta bu kategori minimum 150°F (65°C) ön ısıtma gerektirir.
3/4" to 1-1/2"'de A106 Gr.B için ön ısıtma neden 150°F?
3/4" to 1-1/2"'de SMAW (non-low-hydrogen) ile A106 Gr.B için 150°F ön ısıtma, çeliğin sertleşebilirliği ve bu kalınlıktaki artan kısıtlamanın kombinasyonunu yansıtır.

D1.1:2025 referans verileri. AWS ile bağlantılı değildir.