AWS D1.1:2025 · Tabela 5.11 · Categoria A

Pré-aquecimento de API 5L Gr.B para SMAW (non-low-hydrogen) — 1-1/2" to 2-1/2"

Temperatura mínima de pré-aquecimento e interpasse para API 5L Gr.B soldado com SMAW (non-low-hydrogen) em espessura 1-1/2" to 2-1/2", conforme AWS D1.1:2025 Tabela 5.11.

Baseado na AWS D1.1:2025 Tabela 5.11 — cada valor rastreado à cláusula.

Temperatura Mínima de Pré-aquecimento e Interpasse
225°F / 110°C
Categoria A
Processo SMAW não baixo hidrogênio
AWS D1.1:2025 Tabela 5.11, §5.7
Ferramenta de referência. Verificar contra a edição aplicável ao projeto e EPS aprovada pelo Engenheiro.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

On pipe joints, non-low-hydrogen SMAW root passes with E6010 use the keyhole technique to ensure complete penetration. Pipe rotation (roll welding) is preferred when practical; fixed-position welding requires 5G or 6G qualified procedures. The cellulosic coating generates significant spatter, so adjacent base metal should be protected with anti-spatter compound.

API 5L Gr.B

API 5L Grade B is the baseline pipeline steel specification used for oil, gas, and water transmission lines, with 35 ksi minimum yield and 60 ksi minimum tensile (PSL 1). At PSL 2, tighter chemistry controls (0.22% max carbon, 1.20% max manganese, 0.43% max CE-IIW) improve weldability and toughness consistency. Grade B pipeline joints welded under D1.1 follow Category A (non-low-hydrogen) and Category B (low-hydrogen) preheat requirements. API 5L covers both seamless and welded (HFW, SAW, COWB) pipe in sizes from 1/2" through 80" outside diameter. The pipeline industry typically qualifies procedures under API 1104 rather than D1.1, but structural attachments to pipeline components often fall under D1.1 jurisdiction.

Por que Este Pré-aquecimento para API 5L Gr.B com SMAW

Baseline pipeline steel for oil and gas transmission at 35 ksi yield. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 225°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Aplicações Típicas de API 5L Gr.B

Specified for water transmission mains, natural gas distribution laterals, irrigation pipelines, fire hydrant supply loops, sewer force mains, and gathering system tie-ins. API 5L Gr.B pipeline girth welds use root passes with E6010 cellulosic electrodes followed by fill passes with E7018 or GMAW. Bell-hole repair joints and split-tee hot taps are typical field weld configurations. Pipeline wall thicknesses for municipal water service typically range from 0.250" to 0.500" depending on diameter and operating pressure. Mainline girth welds are radiographically inspected at 100% on high-consequence area crossings and river/road bores. Pipe diameters in municipal water range from 6" to 48" NPS, with 12" to 24" being the most common for trunk mains. Field welders typically qualify on 6G fixed pipe to demonstrate proficiency in all positions encountered during mainline tie-in and repair operations.

Por que o Pré-aquecimento Importa em 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Outros Aços com SMAW (non-low-hydrogen) em 1-1/2" to 2-1/2"

AçoCategoriaPré-aquecimento
A36A225°F (110°C)
A53 Gr.BA225°F (110°C)

API 5L Gr.B com SMAW (non-low-hydrogen)

Experimente Diferentes Combinações

Use a calculadora interativa de pré-aquecimento para consultar qualquer combinação de aço, processo e espessura da D1.1:2025 Tabela 5.11.

Qual é o pré-aquecimento mínimo para API 5L Gr.B com SMAW em 1-1/2" to 2-1/2"?
Para API 5L Gr.B soldado com SMAW (non-low-hydrogen) em espessura 1-1/2" to 2-1/2", a temperatura mínima de pré-aquecimento é 225°F (110°C) conforme AWS D1.1:2025 Tabela 5.11, Categoria A. Esta é também a temperatura mínima de interpasse.
Qual categoria da Tabela 5.11 se aplica a API 5L Gr.B com SMAW?
API 5L Gr.B soldado com SMAW (non-low-hydrogen) se enquadra na Categoria A da AWS D1.1:2025 Tabela 5.11. Processo SMAW não baixo hidrogênio. Em espessura 1-1/2" to 2-1/2", esta categoria requer pré-aquecimento mínimo de 225°F (110°C).
Por que o pré-aquecimento é 225°F para API 5L Gr.B em 1-1/2" to 2-1/2"?
O pré-aquecimento de 225°F para API 5L Gr.B em 1-1/2" to 2-1/2" com SMAW (non-low-hydrogen) reflete a combinação da temperabilidade do aço e a restrição aumentada nesta espessura.

Dados de referência D1.1:2025. Sem afiliação com AWS.