AASHTO/AWS D1.5:2025 · Tabela 12.4/12.5 · Fratura Crítica · H8

Pré-aquecimento M270M Gr.345 — H8, Mid HI, ≤ 20 mm: 100°F

Requisito de pré-aquecimento de fratura crítica para M270M Gr.345 / M270 Gr.50 em espessura ≤ 20 mm (3/4 in) com designação de hidrogênio H8, conforme AASHTO/AWS D1.5:2025.

Baseado na AWS D1.5:2025 — cada valor rastreado à cláusula.

Pré-aquecimento e Interpasse Mínimo de Fratura Crítica
100°F / 40°C
Hidrogênio H8 · aporte de calor 2.0–2.8 kJ/mm · espessura ≤ 20 mm (3/4 in)
AASHTO/AWS D1.5M/D1.5:2025 Tabela 12.4/12.5
Designação H8: o consumível deposita ≤ 8 mL/100g de hidrogênio difusível conforme AWS A4.3. Menor hidrogênio = menor pré-aquecimento.
Ferramenta de referência. Verificar contra a edição aplicável ao projeto e EPS aprovada pelo Engenheiro.

M270M Gr.345 / M270 Gr.50

AASHTO M270M Gr.345 (M270 Gr.50) is the standard bridge plate and shape grade with 345 MPa (50 ksi) minimum yield, corresponding to ASTM A709 Gr.50. It is the baseline strength for modern highway bridge design per AASHTO LRFD. Used for plate girder flanges, webs, floor beams, cross-frames, and splice plates. Flanges on large plate girders routinely reach 50–75 mm (2–3 in) thick, making preheat compliance at upper thickness tiers a significant production consideration. NFC preheat per Table 6.3 Group 1; FC per Tables 12.4/12.5.

Entendendo o Pré-aquecimento FC para M270M Gr.345 / M270 Gr.50

Standard 345 MPa (50 ksi) bridge plate for girders and floor beams. Under D1.5 fracture-critical requirements (Clause 12), the combination of H8 hydrogen designation and this heat input band requires 100°F minimum preheat at ≤ 20 mm (3/4 in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Onde M270M Gr.345 / M270 Gr.50 é Usado

Standard for highway bridge plate girder flanges, box girder webs, cross-frame angles, bearing sole plates, and splice plates in bolted-welded connections. Gr.345 (50) is the baseline strength for modern AASHTO LRFD bridge design. Flange butt splices, web-to-flange continuous fillet welds, and bearing stiffener clips are the dominant weld types in girder fabrication. Girder flanges typically range from 20 to 75 mm (3/4 to 3 in) thick with widths from 300 to 750 mm (12 to 30 in), requiring extended preheat soak times on thicker flange splices.

Controle de Hidrogênio H8 para M270M Gr.345 / M270 Gr.50

Gr.345 (50) with H8 is the standard specification for most bridge fabrication shops. H8 consumables are more widely stocked than H4, providing procurement flexibility without significantly increasing preheat requirements. The preheat increase from H4 to H8 is typically 10–25°F depending on thickness tier.

Por que o Pré-aquecimento Importa em ≤ 20 mm (3/4 in)

Material up to 20 mm (3/4 in) covers most cross-frame angles, stiffener clips, lateral bracing members, and light bridge plate. At this thickness, hydrogen diffusion is efficient and preheat requirements are the lowest in Table 6.3 — 10°C (50°F) for both groups. In FC service, this thickness tier also carries the lowest preheat in Tables 12.4–12.7, starting at 40°C (100°F) for H4 consumables.

M270M Gr.345 / M270 Gr.50 em ≤ 20 mm (3/4 in)

Gr.345 (50) under 20 mm covers web stiffeners, bearing stiffener clips, and cross-frame gusset plates — the highest-volume weld details in girder fabrication. These thin plates are fillet-welded to girder webs using semi-automatic FCAW with E71T-1 wire at 2–4 kg/hr deposition. Preheat is quick to achieve with a rosebud torch and verifiable with a temperature-indicating crayon. Joint fit-up at this thickness is critical because thin plate distortion from uncontrolled heat input causes cumulative girder sweep.

Outros Aços de Ponte em H8 2.0–2.8 kJ/mm · ≤ 20 mm (3/4 in)

AçoTabelaPré-aquecimento
M270M Gr.345W / M270 Gr.50WB100°F (40°C)
M270M HPS345W / M270 HPS50WB100°F (40°C)
M270M HPS485W / M270 HPS70WB100°F (40°C)
M270M Gr.250 / M270 Gr.36A100°F (40°C)

Experimente Diferentes Combinações

Use a Calculadora de Pré-aquecimento D1.5 para Pontes para consultar qualquer aço AASHTO M270, nível de hidrogênio e combinação de aporte de calor. Veja também a Calculadora de Pré-aquecimento D1.1 para aço estrutural.

Qual é o pré-aquecimento FC para M270M Gr.345 / M270 Gr.50 com H8 em ≤ 20 mm (3/4 in)?
Para fratura crítica M270M Gr.345 / M270 Gr.50 soldado com consumíveis designados H8 em espessura ≤ 20 mm (3/4 in) e aporte de calor 2.0–2.8 kJ/mm, o pré-aquecimento mínimo é 100°F (40°C) conforme D1.5 Tabela 12.4/12.5.
Qual é a diferença entre pré-aquecimento FC e NFC para M270M Gr.345 / M270 Gr.50?
O pré-aquecimento não fratura crítica (Tabela 6.3) é uma consulta simples baseada em espessura. O de fratura crítica (Tabelas 12.4–12.8) adiciona nível de hidrogênio e aporte de calor como variáveis.
Como o aporte de calor afeta o pré-aquecimento FC de M270M Gr.345 / M270 Gr.50?
Maior aporte de calor significa taxas de resfriamento mais lentas, dando mais tempo ao hidrogênio para se difundir para fora da zona de solda. Em 2.0–2.8 kJ/mm, o pré-aquecimento de 100°F equilibra o nível de hidrogênio e a taxa de resfriamento.
Is preheat needed for bridge steel under 20 mm?
Yes — D1.5 Table 6.3 requires a minimum of 10°C (50°F) even for the thinnest material in both groups. This is higher than D1.1’s Category B minimum of 0°C (32°F) at the same thickness, reflecting the more conservative approach for bridge structures where fracture consequences are severe.

Dados de referência D1.5:2025. Sem afiliação com AWS ou AASHTO.