AWS D1.1:2025 · 표 5.11 · 범주 A

A709 Gr.36 SMAW (non-low-hydrogen) 예열 — 3/4" to 1-1/2"

AWS D1.1:2025 표 5.11에 따른 A709 Gr.36의 SMAW (non-low-hydrogen) 용접 시 3/4" to 1-1/2" 두께에서의 최소 예열 및 층간 온도.

AWS D1.1:2025 표 5.11 기반 — 모든 값이 조항까지 추적됨.

최소 예열 및 층간 온도
150°F / 65°C
범주 A
비저수소 SMAW 공정
AWS D1.1:2025 표 5.11, §5.7
참조 도구. 프로젝트 적용 판본 및 엔지니어 승인 WPS와 대조 확인하십시오.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For common structural shapes and plate, non-low-hydrogen SMAW with E6010 or E6011 excels at root passes on open-root groove welds where burn-through control matters. Vertical-up technique with a slight weave keeps the puddle manageable. Rod consumption runs about 10-12 electrodes per pound of weld metal deposited. Electrode stubs should be no shorter than 2 inches to maintain adequate arc length control.

A709 Gr.36

ASTM A709 Grade 36 is the bridge-specific equivalent of A36, used exclusively for highway bridge construction under AASHTO LRFD Bridge Design Specifications. With 36 ksi minimum yield, 58-80 ksi tensile, and mandatory Charpy V-notch testing requirements based on AASHTO temperature zone (Zone 1: 70°F, Zone 2: 40°F, Zone 3: 10°F test temperatures), it qualifies for both Category A and Category B preheat in Table 5.11. Chemistry matches A36 (0.26% max carbon) but the CVN requirements add a fracture resistance guarantee absent from plain A36. A709 Gr.36 is primarily used for secondary bridge members — lateral bracing, floor beam stiffeners, diaphragm plates, and bearing components — where Gr.50 strength is not needed but bridge-code CVN compliance is required.

SMAW를 사용한 A709 Gr.36의 이 예열 이유

Bridge-specific 36 ksi grade with CVN testing for highway construction. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 150°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

A709 Gr.36의 일반적인 용도

Specified exclusively for highway bridge deck plate, floor beams, lateral bracing, secondary framing, bridge railing posts, abutment bearing stiffeners, and diaphragm plates. A709 Gr.36 requires CVN testing per AASHTO zone classification, distinguishing it from plain A36 by guaranteeing fracture resistance at the bridge’s design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details in bridge shops. The fracture-critical designation on certain bridge members imposes additional NDT requirements (UT in lieu of RT for CJP welds) and welder qualification testing beyond standard D1.5 provisions. Temperature zones (1 through 3) determine the CVN test temperature for the Charpy specimens: Zone 1 at 70°F for moderate climates, Zone 2 at 40°F for cold climates, and Zone 3 at 10°F for severe cold. Mill certifications must show CVN results meeting the specified zone before plate release to the bridge fabricator.

3/4" to 1-1/2"에서 예열이 중요한 이유

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

3/4" to 1-1/2"에서 SMAW (non-low-hydrogen)를 사용하는 다른 강재

강재범주예열
A36A150°F (65°C)
A53 Gr.BA150°F (65°C)

다양한 조합 시도

인터랙티브 예열 계산기를 사용하여 D1.1:2025 표 5.11의 모든 강재, 공정, 두께 조합을 조회하세요.

3/4" to 1-1/2"에서 SMAW를 사용하여 A709 Gr.36의 최소 예열은 얼마입니까?
3/4" to 1-1/2" 두께에서 SMAW (non-low-hydrogen)로 용접하는 A709 Gr.36의 최소 예열 온도는 AWS D1.1:2025 표 5.11, 범주 A에 따라 150°F (65°C)입니다. 이것은 또한 최소 층간 온도입니다.
SMAW를 사용하는 A709 Gr.36에 어떤 범주가 적용됩니까?
SMAW (non-low-hydrogen)로 용접하는 A709 Gr.36은 AWS D1.1:2025 표 5.11의 범주 A에 해당합니다. 비저수소 SMAW 공정. 3/4" to 1-1/2" 두께에서 이 범주는 최소 150°F (65°C)의 예열을 요구합니다.
3/4" to 1-1/2"에서 A709 Gr.36의 예열이 150°F인 이유는?
3/4" to 1-1/2"에서 SMAW (non-low-hydrogen)로 용접하는 A709 Gr.36의 150°F 예열은 강재의 경화성과 이 두께에서의 증가된 구속력의 조합을 반영합니다.

D1.1:2025 참조 데이터. AWS와 무관.