AWS D1.1:2025 · 표 5.11 · 범주 B

A106 Gr.B FCAW 예열 — up to 3/4"

AWS D1.1:2025 표 5.11에 따른 A106 Gr.B의 FCAW 용접 시 up to 3/4" 두께에서의 최소 예열 및 층간 온도.

AWS D1.1:2025 표 5.11 기반 — 모든 값이 조항까지 추적됨.

최소 예열 및 층간 온도
32°F / 0°C
범주 B 저수소 SMAW, SAW, GMAW 또는 FCAW 공정
AWS D1.1:2025 표 5.11, §5.7
모재 온도가 32°F [0°C] 미만일 때 최소 70°F [20°C]로 예열하고 용접 중 유지하십시오 (표 5.11 각주 a).
참조 도구. 프로젝트 적용 판본 및 엔지니어 승인 WPS와 대조 확인하십시오.

Have a preheat question? Ask Flux

FCAW (Flux Cored Arc Welding)

FCAW uses tubular flux-cored wire, available gas-shielded (E71T-1) or self-shielded (E71T-8) for field work. Category B in Table 5.11.

FCAW on pipe butt joints uses gas-shielded wire for root passes with backing rings or ceramic backup. Self-shielded FCAW excels on pipeline tie-in welds in windy field conditions where gas cups cannot maintain a stable envelope. Typical wire diameter for pipe work is 0.045" for root and 0.052" for fill passes.

Why FCAW for A106 Gr.B at up to 3/4"

Why FCAW for A106 Gr.B at up to 3/4"? FCAW delivers 8-12 lb/hr deposition — compared to SAW at 15-40 lb/hr. Position capability: all positions. Suitability: field and shop.

Filler Metal for FCAW

Gas-shielded: E71T-1C (AWS A5.20, requires 100% CO2) or E71T-1M (requires 75/25 Ar/CO2 mixed gas) — the C/M suffix designates the required shielding gas. Self-shielded: E71T-8 (no external gas, field-ready). Diameter: 0.045" standard, 1/16" for high-deposition. Stick-out: 3/4" to 1-1/4" (longer than GMAW due to resistive heating of flux core).

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

FCAW를 사용한 A106 Gr.B의 이 예열 이유

Seamless pipe rated for high-temperature service up to 750°F. With low-hydrogen FCAW, this combination falls under Category B rather than Category A — flux-cored wire in FCAW provides a combination of deoxidizers and low-moisture flux formulations that control hydrogen. The 32°F minimum preheat is lower than what non-low-hydrogen SMAW would require at the same thickness because FCAW significantly reduces the driving force for hydrogen-induced cracking in the heat-affected zone.

A106 Gr.B의 일반적인 용도

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

up to 3/4"에서 예열이 중요한 이유

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

up to 3/4"에서 FCAW를 사용하는 다른 강재

강재범주예열
A36B32°F (0°C)
A633 Gr.EC50°F (10°C)
A709 HPS70WC50°F (10°C)
A710 Gr.AC50°F (10°C)

다양한 조합 시도

인터랙티브 예열 계산기를 사용하여 D1.1:2025 표 5.11의 모든 강재, 공정, 두께 조합을 조회하세요.

up to 3/4"에서 FCAW를 사용하여 A106 Gr.B의 최소 예열은 얼마입니까?
up to 3/4" 두께에서 FCAW로 용접하는 A106 Gr.B의 최소 예열 온도는 AWS D1.1:2025 표 5.11, 범주 B에 따라 32°F (0°C)입니다. 이것은 또한 최소 층간 온도입니다.
FCAW를 사용하는 A106 Gr.B에 어떤 범주가 적용됩니까?
FCAW로 용접하는 A106 Gr.B은 AWS D1.1:2025 표 5.11의 범주 B에 해당합니다. 저수소 SMAW, SAW, GMAW 또는 FCAW 공정. up to 3/4" 두께에서 이 범주는 최소 32°F (0°C)의 예열을 요구합니다.
up to 3/4"에서 A106 Gr.B에 예열이 필요합니까?
up to 3/4" 두께에서 FCAW로 용접 시 최소 예열은 32°F (0°C)입니다 — 사실상 영상에서의 주위 온도입니다. 모재가 32°F 미만이 아닌 한 능동적 예열이 필요하지 않습니다.