예열 M270M Gr.345S — H4, High HI, > 60 mm: 250°F
AASHTO/AWS D1.5:2025 교량 용접 코드에 따른 > 60 mm (> 2½ in) 두께에서 M270M Gr.345S / M270 Gr.50S의 파괴 임계 예열 요구사항 H4 수소 지정 포함.
AWS D1.5:2025 기반 — 모든 값이 조항까지 추적됨.
M270M Gr.345S / M270 Gr.50S
AASHTO M270M Gr.345S (M270 Gr.50S) is the structural shape variant of Gr.345, intended for rolled W-shapes and channels used in bridge framing. The "S" suffix indicates the shape-specific chemistry and mechanical property requirements. Used in cross-frame angles, diaphragm members, and built-up sections where rolled shapes are specified rather than plate. Preheat requirements match Gr.345 — Table 6.3 Group 1 for NFC, Tables 12.4/12.5 for FC applications.
M270M Gr.345S / M270 Gr.50S의 FC 예열 이해
Shape-grade 345 MPa (50 ksi) steel for rolled bridge members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H4 hydrogen designation and this heat input band requires 250°F minimum preheat at > 60 mm (> 2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.
M270M Gr.345S / M270 Gr.50S이 사용되는 곳
Used as rolled W-shapes and channels in bridge cross-frames, diaphragm members, and built-up sections. The "S" shape designation indicates procurement under AASHTO M270 with shape-specific chemistry and mandatory CVN testing. Common applications include WT sections for cross-frame members, MC channels for diaphragms, and W-shapes for floor beams on shorter spans. Weld details are primarily fillet welds at gusset connections and clip angles.
M270M Gr.345S / M270 Gr.50S의 H4 수소 제어
Shape-grade Gr.345S (50S) benefits from H4 at gusset-to-shape connections where access for torch preheat is limited by flanges and stiffeners. The lower preheat achievable with H4 reduces the thermal management complexity in tight spaces typical of cross-frame subassemblies.
> 60 mm (> 2½ in)에서 예열이 중요한 이유
Material over 65 mm (2-1/2 in) includes the heaviest bridge girder flanges and box-section walls. Table 6.3 requires 110°C (225°F) for both groups at this thickness. Extended preheat soak time is necessary to achieve uniform through-thickness temperature. FC preheat for the heaviest sections reaches 180–200°C (350–400°F) at the H16 hydrogen level.
> 60 mm (> 2½ in)에서의 M270M Gr.345S / M270 Gr.50S
Gr.345S (50S) above 65 mm flange thickness is limited to the heaviest jumbo W-shapes (W14×730 or similar) used in critical transfer structures. These sections have significant residual stress from the rolling process that compounds with welding stresses. Full 225°F preheat plus controlled cooling is essential — some fabricators specify post-weld hydrogen release holds at 400°F for 2 hours on jumbo section connections.
FC 교량 용접용 H4 인증 용접재료
H4 보조 지정은 용접재료가 용착 금속 100g당 최대 4 mL의 확산성 수소를 방출함을 인증합니다. 파괴 임계 M270M Gr.345S / M270 Gr.50S에서 > 60 mm (> 2½ in) 두께, > 2.8 kJ/mm 입열량 시 H4 용접재료는 FC 표에서 가장 낮은 예열 250°F (120°C)를 달성합니다.
H4 > 2.8 kJ/mm · > 60 mm (> 2½ in)에서의 다른 교량 강재
| 강재 | 표 | 예열 |
|---|---|---|
| M270M Gr.250 / M270 Gr.36 | A | 250°F (120°C) |
| M270M Gr.345W / M270 Gr.50W | B | 300°F (150°C) |
| M270M HPS345W / M270 HPS50W | B | 300°F (150°C) |
| M270M HPS485W / M270 HPS70W | B | 300°F (150°C) |
H4 > 2.8 kJ/mm에서의 M270M Gr.345S / M270 Gr.50S
관련 가이드
D1.5:2025 참조 데이터. AWS 또는 AASHTO와 무관.