AASHTO/AWS D1.5:2025 · 표 12.4/12.5 · 파괴 임계 · H4

예열 M270M Gr.250 — H4, High HI, ≤ 20 mm: 100°F

AASHTO/AWS D1.5:2025 교량 용접 코드에 따른 ≤ 20 mm (3/4 in) 두께에서 M270M Gr.250 / M270 Gr.36의 파괴 임계 예열 요구사항 H4 수소 지정 포함.

AWS D1.5:2025 기반 — 모든 값이 조항까지 추적됨.

파괴 임계 최소 예열 및 층간온도
100°F / 40°C
수소 H4 · 입열량 > 2.8 kJ/mm · 두께 ≤ 20 mm (3/4 in)
AASHTO/AWS D1.5M/D1.5:2025 표 12.4/12.5
H4 지정: 용접재료가 AWS A4.3에 따라 ≤ 4 mL/100g 확산성 수소를 방출합니다. 낮은 수소 = 낮은 예열.
참조 도구. 프로젝트 적용 판본 및 엔지니어 승인 WPS와 대조 확인하십시오.

M270M Gr.250 / M270 Gr.36

AASHTO M270M Gr.250 (M270 Gr.36) is the metric/US customary designation for the basic structural bridge steel with 250 MPa (36 ksi) minimum yield. It is the direct bridge equivalent of ASTM A709 Gr.36, procured under AASHTO M270 with mandatory Charpy V-notch testing per temperature zone. Used for secondary bridge members — lateral bracing, diaphragm plates, floor beam stiffeners, and bearing components where Gr.345 strength is not needed. Non-fracture-critical preheat follows Table 6.3 Group 1; fracture-critical follows Tables 12.4/12.5 with hydrogen and heat input as additional variables.

M270M Gr.250 / M270 Gr.36의 FC 예열 이해

Basic 250 MPa (36 ksi) bridge steel for secondary members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H4 hydrogen designation and this heat input band requires 100°F minimum preheat at ≤ 20 mm (3/4 in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

M270M Gr.250 / M270 Gr.36이 사용되는 곳

Specified for secondary bridge members under AASHTO LRFD — lateral bracing angles, diaphragm plates, floor beam stiffeners, bearing seat components, and railing posts. Gr.250 (36) requires CVN testing per AASHTO temperature zone, distinguishing it from plain ASTM A36 by guaranteeing fracture resistance at the bridge design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details. Temperature zones (1 through 3) determine CVN test temperature: Zone 1 at 21°C (70°F) for moderate climates, Zone 2 at 4°C (40°F) for cold, Zone 3 at -12°C (10°F) for severe cold.

M270M Gr.250 / M270 Gr.36의 H4 수소 제어

For Gr.250 (36), the H4 restriction to 4 mL/100g diffusible hydrogen provides the widest margin against cold cracking in secondary bridge members. The low carbon equivalent of Gr.250 already makes it one of the least crack-sensitive bridge steels, so the practical benefit of H4 over H8 is primarily preheat reduction — often 10–20°C (20–40°F) lower, which speeds production on high-volume stiffener and bracing fabrication.

≤ 20 mm (3/4 in)에서 예열이 중요한 이유

Material up to 20 mm (3/4 in) covers most cross-frame angles, stiffener clips, lateral bracing members, and light bridge plate. At this thickness, hydrogen diffusion is efficient and preheat requirements are the lowest in Table 6.3 — 10°C (50°F) for both groups. In FC service, this thickness tier also carries the lowest preheat in Tables 12.4–12.7, starting at 40°C (100°F) for H4 consumables.

≤ 20 mm (3/4 in)에서의 M270M Gr.250 / M270 Gr.36

Gr.250 (36) at up to 20 mm is the lightest bridge fabrication scenario — cross-frame angles, stiffener clips, and lateral bracing gussets. Hydrogen diffusion through this thin section is rapid, so preheat has the least influence on cracking resistance. Most fabricators use E7018 SMAW for short fillet welds at this thickness because the joint lengths are too short for mechanized FCAW setup to be economical. Interpass monitoring is minimal at this tier because heat builds slowly in thin plate.

FC 교량 용접용 H4 인증 용접재료

H4 보조 지정은 용접재료가 용착 금속 100g당 최대 4 mL의 확산성 수소를 방출함을 인증합니다. 파괴 임계 M270M Gr.250 / M270 Gr.36에서 ≤ 20 mm (3/4 in) 두께, > 2.8 kJ/mm 입열량 시 H4 용접재료는 FC 표에서 가장 낮은 예열 100°F (40°C)를 달성합니다.

H4 > 2.8 kJ/mm · ≤ 20 mm (3/4 in)에서의 다른 교량 강재

강재예열
M270M Gr.345W / M270 Gr.50WB100°F (40°C)
M270M HPS345W / M270 HPS50WB100°F (40°C)
M270M HPS485W / M270 HPS70WB100°F (40°C)
M270M Gr.345 / M270 Gr.50A100°F (40°C)

다양한 조합 시도

D1.5 교량 예열 계산기를 사용하여 AASHTO M270 강재, 수소 수준 및 입열량 조합을 조회하세요. D1.1 예열 계산기도 참조하세요.

≤ 20 mm (3/4 in)에서 H4을 사용하는 M270M Gr.250 / M270 Gr.36의 FC 예열은 얼마입니까?
H4 지정 용접재료로 ≤ 20 mm (3/4 in) 두께, > 2.8 kJ/mm 입열량에서 용접하는 파괴 임계 M270M Gr.250 / M270 Gr.36의 최소 예열은 D1.5 표 12.4/12.5에 따라 100°F (40°C)입니다.
M270M Gr.250 / M270 Gr.36의 FC와 NFC 예열의 차이는 무엇입니까?
비파괴 임계 예열(표 6.3)은 단순한 두께 기반 조회입니다. 파괴 임계 예열(표 12.4–12.8)은 수소 수준과 입열량을 변수로 추가하여 일반적으로 더 높은 예열을 요구합니다.
입열량은 M270M Gr.250 / M270 Gr.36의 FC 예열에 어떤 영향을 미칩니까?
높은 입열량은 느린 냉각 속도를 의미하여 수소가 용접부에서 확산할 시간을 더 줍니다. > 2.8 kJ/mm에서 100°F 예열은 수소 수준과 냉각 속도의 균형을 맞춥니다.
Is preheat needed for bridge steel under 20 mm?
Yes — D1.5 Table 6.3 requires a minimum of 10°C (50°F) even for the thinnest material in both groups. This is higher than D1.1’s Category B minimum of 0°C (32°F) at the same thickness, reflecting the more conservative approach for bridge structures where fracture consequences are severe.

D1.5:2025 참조 데이터. AWS 또는 AASHTO와 무관.