AASHTO/AWS D1.5:2025 · 表12.4/12.5 · 破壊臨界 · H16

M270M Gr.345S予熱 — H16、Low HI、40–60 mm: 250°F

AASHTO/AWS D1.5:2025(橋梁溶接規格)に基づく、40–60 mm (1½–2½ in)板厚、水素指定H16でのにおけるM270M Gr.345S / M270 Gr.50Sの破壊臨界予熱要件。

AWS D1.5:2025に基づく — すべての値は条項に追跡可能。

破壊臨界 最低予熱・パス間温度
250°F / 120°C
H16水素 · 1.2–2.0 kJ/mm入熱 · 40–60 mm (1½–2½ in)板厚
AASHTO/AWS D1.5M/D1.5:2025 表12.4/12.5
H16指定: AWS A4.3に基づき溶接材料は≤16 mL/100gの拡散性水素を溶着。水素が低いほど予熱要件も低くなります。
参考ツール。プロジェクト適用版およびエンジニア承認済みWPSで確認すること。

M270M Gr.345S / M270 Gr.50S

AASHTO M270M Gr.345S (M270 Gr.50S) is the structural shape variant of Gr.345, intended for rolled W-shapes and channels used in bridge framing. The "S" suffix indicates the shape-specific chemistry and mechanical property requirements. Used in cross-frame angles, diaphragm members, and built-up sections where rolled shapes are specified rather than plate. Preheat requirements match Gr.345 — Table 6.3 Group 1 for NFC, Tables 12.4/12.5 for FC applications.

M270M Gr.345S / M270 Gr.50SのFC予熱を理解する

Shape-grade 345 MPa (50 ksi) steel for rolled bridge members. Under D1.5 fracture-critical requirements (Clause 12), the combination of H16 hydrogen designation and this heat input band requires 250°F minimum preheat at 40–60 mm (1½–2½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

M270M Gr.345S / M270 Gr.50Sの使用箇所

Used as rolled W-shapes and channels in bridge cross-frames, diaphragm members, and built-up sections. The "S" shape designation indicates procurement under AASHTO M270 with shape-specific chemistry and mandatory CVN testing. Common applications include WT sections for cross-frame members, MC channels for diaphragms, and W-shapes for floor beams on shorter spans. Weld details are primarily fillet welds at gusset connections and clip angles.

M270M Gr.345S / M270 Gr.50SにおけるH16水素管理

Gr.345S (50S) at H16 applies primarily to field-erected cross-frame connections using self-shielded FCAW. The higher preheat requirement at H16 can be challenging to maintain on thin shape flanges that lose heat rapidly to the surrounding air — electric resistance heating pads help maintain uniform temperature.

40–60 mm (1½–2½ in)で予熱が重要な理由

Material from 40 to 65 mm (1-1/2 to 2-1/2 in) covers heavy girder flanges, thick splice plates, and main member plate. This is the critical thickness range for bridge fabrication — preheat reaches 65°C (150°F) for Group 1 and 80°C (175°F) for Group 2. FC preheat at this thickness can exceed 200°C (400°F) depending on hydrogen level and heat input.

40–60 mm (1½–2½ in)でのM270M Gr.345S / M270 Gr.50S

Gr.345S (50S) shapes at 40–65 mm flange thickness are heavy built-up members — typically W14×426 or similar jumbo sections used as pier cap beams or transfer girders. The thick flanges of these shapes require full preheat per the heavy-section tier. Welding on thick rolled sections is complicated by residual stresses from rolling — preheat helps mitigate the cumulative effect of rolling residual stress plus welding shrinkage stress.

H16指定での高い予熱

H16溶接材料は100gあたり最大16mLの拡散性水素を許容します — 橋梁FC溶接で許可される最高レベルです。1.2–2.0 kJ/mm入熱での40–60 mm (1½–2½ in)では、250°F (120°C)予熱が高い水素ポテンシャルを補います。この継手にH8またはH4溶接材料に切り替えると必要な予熱が低下します。

H16 1.2–2.0 kJ/mm · 40–60 mm (1½–2½ in)における他の橋梁鋼材

鋼材予熱
M270M Gr.250 / M270 Gr.36A250°F (120°C)
M270M Gr.345W / M270 Gr.50WB350°F (180°C)
M270M HPS345W / M270 HPS50WB350°F (180°C)
M270M HPS485W / M270 HPS70WB350°F (180°C)

別の組み合わせを試す

D1.5橋梁予熱計算機を使用して、AASHTO M270鋼材の水素レベルと入熱の任意の組み合わせを検索できます。構造用鋼にはD1.1予熱計算機もご覧ください。

40–60 mm (1½–2½ in)でのH16を使用したM270M Gr.345S / M270 Gr.50SのFC予熱は?
H16指定溶接材料を使用して40–60 mm (1½–2½ in)板厚、1.2–2.0 kJ/mm入熱で溶接した破壊臨界M270M Gr.345S / M270 Gr.50Sの最低予熱は、D1.5 表12.4/12.5に基づき250°F (120°C)です。
M270M Gr.345S / M270 Gr.50SのFC予熱とNFC予熱の違いは?
非破壊臨界(表6.3)予熱は単純な板厚ベースの検索です。破壊臨界(表12.4〜12.8)は水素レベルと入熱を変数として追加し、通常より高い予熱を必要とします。FC部材では、溶接材料分類の水素指定が直接最低予熱を決定します。
入熱はFC M270M Gr.345S / M270 Gr.50Sの予熱にどう影響する?
高い入熱は冷却速度が遅くなることを意味し、水素が溶接ゾーンから拡散する時間が増えます。1.2–2.0 kJ/mmでは、250°F予熱が水素レベルと冷却速度のバランスをとります。同じ水素レベルと板厚で入熱バンドを上げると、通常は必要な予熱が低下します。
What preheat is needed for 50 mm thick bridge plate?
For non-fracture-critical: 65°C (150°F) for Group 1 grades, 80°C (175°F) for Group 2. For fracture-critical: consult Tables 12.4–12.8 based on the specific steel grade, hydrogen designator, and heat input. FC preheat at this thickness is typically 90–200°C (200–400°F) depending on those variables.