AASHTO/AWS D1.5:2025 · Tabella 12.8 · Frattura Critica

Preriscaldo HPS690W — 2.0–2.8 kJ/mm, 25–50 mm: 250–400°F

Requisito di preriscaldo di frattura critica per M270M HPS690W / M270 HPS100W a spessore 25–50 mm (1–2 in), secondo AASHTO/AWS D1.5:2025, il Codice di Saldatura dei Ponti.

Basato su AWS D1.5:2025 — ogni valore tracciato alla clausola.

Intervallo di Preriscaldo di Frattura Critica
250–400°F / 120–200°C
Tabella 12.8 — apporto termico 2.0–2.8 kJ/mm a spessore 25–50 mm (1–2 in)
AASHTO/AWS D1.5M/D1.5:2025 Tabella 12.8
Sia la temperatura minima CHE massima di preriscaldo/interpass devono essere mantenute. Superare 400°F rischia di degradare la microstruttura Q&T.
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

M270M HPS690W / M270 HPS100W

AASHTO M270M HPS690W (M270 HPS100W) is the highest-strength bridge steel at 690 MPa (100 ksi) yield, reserved for the most demanding long-span and cable-stayed bridge applications. It follows a completely different FC preheat table (Table 12.8) with min-max ranges and many prohibited thickness-heat input combinations marked with “—”. Table 12.8 requires H4 or H8 designated consumables; H16 is not permitted. NFC preheat per Table 6.3 Group 2; maximum interpass per Table 6.4 is 205°C (400°F) for material up to 40 mm, 230°C (450°F) above.

Dove Viene Usato M270M HPS690W / M270 HPS100W

Reserved for the most demanding long-span and cable-stayed bridge applications where maximum weight reduction justifies the material cost premium and fabrication complexity. Table 12.8 imposes both minimum AND maximum preheat limits, and many thickness-heat input combinations are outright prohibited. Fabricators must plan weld procedures around the permitted combinations before cutting plate. Filler metals must carry the H4 or H8 supplemental designator — H16 is not permitted for HPS690W FC applications.

M270M HPS690W / M270 HPS100W a 25–50 mm (1–2 in)

HPS690W (HPS100W) at 40–65 mm is the thickest plate commonly used with this grade. Many thickness-heat input combinations at this tier are prohibited in Table 12.8 — the fabricator must verify that the planned welding procedure matches a permitted cell before beginning production. The permitted preheat ranges narrow further, often spanning only 50°F between minimum and maximum, making continuous temperature monitoring essential.

Controllo Preriscaldo Min–Max per M270M HPS690W / M270 HPS100W

Highest-strength 690 MPa (100 ksi) bridge steel with restricted FC combinations. Table 12.8 specifies a preheat RANGE of 250–400°F for this thickness and heat input combination. Unlike other FC grades, HPS690W requires both minimum AND maximum preheat control because the Q&T microstructure is sensitive to both excessive and insufficient heat. Many thickness-heat input combinations are prohibited ("—" in the table) because no safe preheat window exists — the steel cannot be reliably welded under those conditions.

Prova Diverse Combinazioni

Usa il Calcolatore Preriscaldo D1.5 per Ponti per consultare qualsiasi acciaio AASHTO M270, livello di idrogeno e combinazione di apporto termico. Vedi anche il Calcolatore Preriscaldo D1.1 per acciaio strutturale.

Qual è l'intervallo di preriscaldo per HPS690W a 25–50 mm (1–2 in) con 2.0–2.8 kJ/mm?
La Tabella 12.8 del D1.5 richiede un intervallo di preriscaldo di 250–400°F (120–200°C) per HPS690W a 25–50 mm (1–2 in) con apporto termico 2.0–2.8 kJ/mm. Sia il minimo CHE il massimo devono essere controllati.
Perché HPS690W ha un limite massimo di preriscaldo?
HPS690W raggiunge la sua resistenza di 690 MPa (100 ksi) tramite tempra e rinvenimento. Un preriscaldo eccessivo può ammorbidire la microstruttura temprata nella zona termicamente alterata. Il limite massimo di 400°F (200°C) protegge questa condizione Q&T.

Dati di riferimento D1.5:2025. Non affiliato con AWS o AASHTO.