AWS D1.1:2025 · Tableau 5.11 · Catégorie A

Préchauffage de API 5L Gr.B pour SMAW (non-low-hydrogen) — over 2-1/2"

Température minimale de préchauffage et entre passes pour API 5L Gr.B soudé avec SMAW (non-low-hydrogen) à over 2-1/2" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
300°F / 150°C
Catégorie A
Procédé SMAW non bas hydrogène
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

On pipe joints, non-low-hydrogen SMAW root passes with E6010 use the keyhole technique to ensure complete penetration. Pipe rotation (roll welding) is preferred when practical; fixed-position welding requires 5G or 6G qualified procedures. The cellulosic coating generates significant spatter, so adjacent base metal should be protected with anti-spatter compound.

API 5L Gr.B

API 5L Grade B is the baseline pipeline steel specification used for oil, gas, and water transmission lines, with 35 ksi minimum yield and 60 ksi minimum tensile (PSL 1). At PSL 2, tighter chemistry controls (0.22% max carbon, 1.20% max manganese, 0.43% max CE-IIW) improve weldability and toughness consistency. Grade B pipeline joints welded under D1.1 follow Category A (non-low-hydrogen) and Category B (low-hydrogen) preheat requirements. API 5L covers both seamless and welded (HFW, SAW, COWB) pipe in sizes from 1/2" through 80" outside diameter. The pipeline industry typically qualifies procedures under API 1104 rather than D1.1, but structural attachments to pipeline components often fall under D1.1 jurisdiction.

Pourquoi ce Préchauffage pour API 5L Gr.B avec SMAW

Baseline pipeline steel for oil and gas transmission at 35 ksi yield. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Applications Typiques de API 5L Gr.B

Specified for water transmission mains, natural gas distribution laterals, irrigation pipelines, fire hydrant supply loops, sewer force mains, and gathering system tie-ins. API 5L Gr.B pipeline girth welds use root passes with E6010 cellulosic electrodes followed by fill passes with E7018 or GMAW. Bell-hole repair joints and split-tee hot taps are typical field weld configurations. Pipeline wall thicknesses for municipal water service typically range from 0.250" to 0.500" depending on diameter and operating pressure. Mainline girth welds are radiographically inspected at 100% on high-consequence area crossings and river/road bores. Pipe diameters in municipal water range from 6" to 48" NPS, with 12" to 24" being the most common for trunk mains. Field welders typically qualify on 6G fixed pipe to demonstrate proficiency in all positions encountered during mainline tie-in and repair operations.

Pourquoi le Préchauffage est Important à over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Autres Aciers avec SMAW (non-low-hydrogen) à over 2-1/2"

AcierCatégoriePréchauffage
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

API 5L Gr.B avec SMAW (non-low-hydrogen)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour API 5L Gr.B avec SMAW à over 2-1/2" ?
Pour API 5L Gr.B soudé avec SMAW (non-low-hydrogen) à over 2-1/2" d'épaisseur, la température minimale de préchauffage est 300°F (150°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie A. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à API 5L Gr.B avec SMAW ?
API 5L Gr.B soudé avec SMAW (non-low-hydrogen) relève de la Catégorie A dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW non bas hydrogène. À over 2-1/2" d'épaisseur, cette catégorie exige un préchauffage minimum de 300°F (150°C).
Pourquoi le préchauffage est-il de 300°F pour API 5L Gr.B à over 2-1/2" ?
Le préchauffage de 300°F pour API 5L Gr.B à over 2-1/2" avec SMAW (non-low-hydrogen) reflète la combinaison de la trempabilité de l'acier et la contrainte accrue à cette épaisseur.