Préchauffage de A913 Gr.80 pour SMAW-LH (H4) — up to 3/4"
Température minimale de préchauffage et entre passes pour A913 Gr.80 soudé avec SMAW-LH (H4) à up to 3/4" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.
Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.
Consommables certifiés H4 — contrôle d'hydrogène le plus strict
SMAW (Low-Hydrogen)
Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.
For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.
A913 Gr.80
ASTM A913 Grade 80 (80 ksi yield, 95 ksi minimum tensile) is the highest-strength TMCP shape specification in D1.1, produced exclusively by the QST process. It requires H4-certified consumables (the strictest hydrogen control at ≤4 mL/100g deposited weld metal per AWS A4.3) and falls exclusively under Category G, which has four thickness-dependent preheat tiers (32°F up to 3/4”, 50°F up to 1-1/2”, 150°F up to 2-1/2”, 225°F above). No other hydrogen designation, standard low-hydrogen, or non-low-hydrogen SMAW is prequalified for this grade under Table 5.11. The H4 requirement limits the available consumable pool significantly — only select electrode classifications carry the H4 designator. A913 Gr.80 availability is limited to heavy W14 column sections from a small number of domestic and international mills, with procurement lead times typically 16-24 weeks.
Pourquoi ce Préchauffage pour A913 Gr.80 avec SMAW-LH
Highest-strength 80 ksi TMCP shape requiring H4 consumables exclusively. This steel requires H4-certified consumables — the strictest hydrogen control in Table 5.11 at no more than 4 mL diffusible hydrogen per 100g. At 32°F with SMAW-LH, the four thickness-dependent preheat tiers in Category G reflect the balance between the steel's 80 ksi yield strength and the exceptional hydrogen control provided by H4 certification. No other hydrogen designation is prequalified for this grade.
Applications Typiques de A913 Gr.80
Reserved for the most demanding column applications in super-tall structures, typically interior gravity columns carrying 50+ stories of tributary load. A913 Gr.80 allows W14 sections to replace built-up box columns, simplifying connections and reducing fabrication cost while maintaining equivalent axial capacity. Every weld on this grade demands verified H4 consumables and documented preheat compliance — no exceptions or substitutions are permitted under Table 5.11. Column splice CJP welds require UT inspection per D1.1 Table 8.2. Only a limited number of domestic mills produce A913 Gr.80 shapes, with lead times of 16-24 weeks for non-stock sizes. The H4 consumable requirement eliminates most standard electrode inventory and requires dedicated electrode orders for each project. Fabricators must establish verified H4 supply chains before bidding Gr.80 column work, as H4-designated electrodes are not stocked by most welding distributors. Rejected consumable certifications can delay erection schedules by weeks.
Pourquoi le Préchauffage est Important à up to 3/4"
Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.
Consommables Certifiés H4 pour A913 Gr.80
La Catégorie G est exclusive à l'A913 Gr.80 et exige des consommables certifiés H4 — le contrôle d'hydrogène le plus strict dans D1.1 avec au maximum 4 mL d'hydrogène diffusible par 100g de métal déposé. Les consommables standard bas hydrogène ou H8 ne sont pas préqualifiés pour cette nuance.
A913 Gr.80 avec SMAW-LH (H4)
Essayez Différentes Combinaisons
Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.
Guides de Soudage de A913 Gr.80
Données de référence D1.1:2025. Non affilié à l'AWS.