AWS D1.1:2025 · Tableau 5.11 · Catégorie C

Préchauffage de A709 HPS70W pour SAW — up to 3/4"

Température minimale de préchauffage et entre passes pour A709 HPS70W soudé avec SAW à up to 3/4" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
50°F / 10°C
Catégorie C
Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance)
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

SAW (Submerged Arc Welding)

SAW submerges the arc beneath granular flux for highest deposition rates, flat/horizontal only. Category B in Table 5.11.

SAW on high-strength plate requires careful selection of wire-flux combinations to meet both tensile matching and toughness requirements. F8A4-EA2 or similar high-performance combinations serve Category C steels. Heat input control is particularly important on TMCP grades because SAW naturally deposits high heat input due to the deeply penetrating arc.

Why SAW for A709 HPS70W at up to 3/4"

Why SAW for A709 HPS70W at up to 3/4"? SAW delivers 15-40 lb/hr deposition — the highest deposition rate among available processes. Position capability: flat and horizontal only. Suitability: shop only.

Filler Metal for SAW

Wire: EM12K or EL12 with matching flux (AWS A5.17). Common combo: F7A2-EM12K. Diameter: 3/32" or 7/64". Flux type: active (A) for single-pass, neutral (N) for multi-pass. Voltage: 28-34V. Current: 400-800A depending on joint size. Travel: 12-24 ipm.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

A709 HPS70W

ASTM A709 HPS70W is the highest-strength weathering bridge steel with 70 ksi minimum yield and 85-110 ksi tensile range, used in long-span bridges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate in thicknesses up to 4", its high strength places it in Category C of Table 5.11 with correspondingly higher preheat requirements. Table 5.11 footnote (b) sets a maximum preheat/interpass of 400°F for thickness up to 1-1/2” and 450°F for thicker material — this upper limit is unusual in D1.1 and exists because the Q&T microstructure can be degraded by excessive heat. The chemistry includes copper (0.25-0.40%), nickel (0.65-1.00%), and chromium (0.40-0.65%) for atmospheric corrosion resistance, with 0.19% max carbon keeping the CE-IIW in the 0.46-0.52 range.

Pourquoi ce Préchauffage pour A709 HPS70W avec SAW

Highest-strength 70 ksi weathering bridge steel for long-span applications. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 50°F minimum with SAW, the submerged arc process with granular flux produces controlled hydrogen levels, with flux condition being the primary variable, but the preheat must still ensure the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material.

Applications Typiques de A709 HPS70W

Reserved for long-span bridge main girder flanges, cable-stayed bridge edge girders, arch rib plates, high-load interchange ramp girders, and situations where reducing member depth saves clearance or reduces dead load. HPS70W enables weight savings of 20-30% versus conventional Gr.50 designs, allowing shallower girder sections that reduce embankment costs on grade-separation bridges. Flange thickness often exceeds 2”, making preheat and interpass control critical at every CJP splice and web-to-flange joint. Note that Table 5.11 footnote (b) sets maximum preheat and interpass limits of 400°F for thicknesses up to 1-1/2" and 450°F above. This upper limit is unusual in D1.1 and requires monitoring both minimum and maximum interpass throughout the welding sequence. Fabricators must use dual-readout temperature monitoring to ensure the joint stays within the qualified band. Filler metals must match the 70 ksi minimum tensile while providing weathering-compatible chemistry for exposed joints.

Pourquoi le Préchauffage est Important à up to 3/4"

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

Préchauffage Catégorie C pour A709 HPS70W

La Catégorie C du Tableau 5.11 s'applique aux aciers à haute résistance où la combinaison de trempabilité et de contrainte résiduelle exige un préchauffage élevé. Pour A709 HPS70W à up to 3/4", le préchauffage minimum de 50°F ralentit le taux de refroidissement de la soudure pour prévenir la formation de martensite susceptible de fissuration dans la zone affectée thermiquement.

Autres Aciers avec SAW à up to 3/4"

AcierCatégoriePréchauffage
A36B32°F (0°C)
A53 Gr.BB32°F (0°C)
A106 Gr.BB32°F (0°C)
A633 Gr.EC50°F (10°C)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour A709 HPS70W avec SAW à up to 3/4" ?
Pour A709 HPS70W soudé avec SAW à up to 3/4" d'épaisseur, la température minimale de préchauffage est 50°F (10°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie C. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à A709 HPS70W avec SAW ?
A709 HPS70W soudé avec SAW relève de la Catégorie C dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance). À up to 3/4" d'épaisseur, cette catégorie exige un préchauffage minimum de 50°F (10°C).

Données de référence D1.1:2025. Non affilié à l'AWS.