AWS D1.1:2025 · Tableau 5.11 · Catégorie C

Préchauffage de A709 HPS70W pour FCAW — 1-1/2" to 2-1/2"

Température minimale de préchauffage et entre passes pour A709 HPS70W soudé avec FCAW à 1-1/2" to 2-1/2" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
225°F / 110°C
Catégorie C Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance)
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

Have a preheat question? Ask Flux

FCAW (Flux Cored Arc Welding)

FCAW uses tubular flux-cored wire, available gas-shielded (E71T-1) or self-shielded (E71T-8) for field work. Category B in Table 5.11.

High-strength FCAW wires such as E81T1-K2 and E91T1-K2 provide tensile matching for Category C steels. The flux system in these wires is formulated for low diffusible hydrogen, often meeting H8 supplementary limits when tested per AWS A4.3. Wire storage requires climate-controlled conditions similar to SMAW electrodes to prevent moisture absorption.

FCAW Tips for High-Strength and TMCP Steels

For A709 HPS70W weathering bridge steel (70 ksi yield, Q&T plate, Category C), FCAW requires higher-strength weathering-compatible wire — E81T1-W2 or similar for both tensile matching and corrosion resistance on exposed joints. Category C minimum preheat: 50°F up to 3/4", stepping to 300°F above 2-1/2". Note: Table 5.11 also sets maximum interpass (400°F up to 1-1/2", 450°F above) to protect.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Filler Metal for FCAW

Gas-shielded: E71T-1C (AWS A5.20, requires 100% CO2) or E71T-1M (requires 75/25 Ar/CO2 mixed gas) — the C/M suffix designates the required shielding gas. Self-shielded: E71T-8 (no external gas, field-ready). Diameter: 0.045" standard, 1/16" for high-deposition. Stick-out: 3/4" to 1-1/4" (longer than GMAW due to resistive heating of flux core).

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

A709 HPS70W

ASTM A709 HPS70W is the highest-strength weathering bridge steel with 70 ksi minimum yield and 85-110 ksi tensile range, used in long-span bridges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate in thicknesses up to 4", its high strength places it in Category C of Table 5.11 with correspondingly higher preheat requirements. Table 5.11 footnote (b) sets a maximum preheat/interpass of 400°F for thickness up to 1-1/2” and 450°F for thicker material — this upper limit is unusual in D1.1 and exists because the Q&T microstructure can be degraded by excessive heat. The chemistry includes copper (0.25-0.40%), nickel (0.65-1.00%), and chromium (0.40-0.65%) for atmospheric corrosion resistance, with 0.19% max carbon keeping the CE-IIW in the 0.46-0.52 range.

Pourquoi ce Préchauffage pour A709 HPS70W avec FCAW

Highest-strength 70 ksi weathering bridge steel for long-span applications. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 225°F minimum with FCAW, flux-cored wire in FCAW provides a combination of deoxidizers and low-moisture flux formulations that control hydrogen, but the preheat must still ensure the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material.

Applications Typiques de A709 HPS70W

Reserved for long-span bridge main girder flanges, cable-stayed bridge edge girders, arch rib plates, high-load interchange ramp girders, and situations where reducing member depth saves clearance or reduces dead load. HPS70W enables weight savings of 20-30% versus conventional Gr.50 designs, allowing shallower girder sections that reduce embankment costs on grade-separation bridges. Flange thickness often exceeds 2”, making preheat and interpass control critical at every CJP splice and web-to-flange joint. Note that Table 5.11 footnote (b) sets maximum preheat and interpass limits of 400°F for thicknesses up to 1-1/2" and 450°F above. This upper limit is unusual in D1.1 and requires monitoring both minimum and maximum interpass throughout the welding sequence. Fabricators must use dual-readout temperature monitoring to ensure the joint stays within the qualified band. Filler metals must match the 70 ksi minimum tensile while providing weathering-compatible chemistry for exposed joints.

Pourquoi le Préchauffage est Important à 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Préchauffage Catégorie C pour A709 HPS70W

La Catégorie C du Tableau 5.11 s'applique aux aciers à haute résistance où la combinaison de trempabilité et de contrainte résiduelle exige un préchauffage élevé. Pour A709 HPS70W à 1-1/2" to 2-1/2", le préchauffage minimum de 225°F ralentit le taux de refroidissement de la soudure pour prévenir la formation de martensite susceptible de fissuration dans la zone affectée thermiquement.

Autres Aciers avec FCAW à 1-1/2" to 2-1/2"

AcierCatégoriePréchauffage
A36B150°F (65°C)
A53 Gr.BB150°F (65°C)
A106 Gr.BB150°F (65°C)
A633 Gr.EC225°F (110°C)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour A709 HPS70W avec FCAW à 1-1/2" to 2-1/2" ?
Pour A709 HPS70W soudé avec FCAW à 1-1/2" to 2-1/2" d'épaisseur, la température minimale de préchauffage est 225°F (110°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie C. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à A709 HPS70W avec FCAW ?
A709 HPS70W soudé avec FCAW relève de la Catégorie C dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance). À 1-1/2" to 2-1/2" d'épaisseur, cette catégorie exige un préchauffage minimum de 225°F (110°C).
Pourquoi le préchauffage est-il de 225°F pour A709 HPS70W à 1-1/2" to 2-1/2" ?
Le préchauffage de 225°F pour A709 HPS70W à 1-1/2" to 2-1/2" avec FCAW reflète la combinaison de la trempabilité de l'acier et la contrainte accrue à cette épaisseur.

Données de référence D1.1:2025. Non affilié à l'AWS.