AWS D1.1:2025 · Tableau 5.11 · Catégorie A

Préchauffage de A516 Gr.55/60 pour SMAW (non-low-hydrogen) — 3/4" to 1-1/2"

Température minimale de préchauffage et entre passes pour A516 Gr.55/60 soudé avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
150°F / 65°C
Catégorie A
Procédé SMAW non bas hydrogène
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For pressure vessel plate, non-low-hydrogen SMAW is typically limited to non-pressure attachments and temporary fit-up clips. Code requirements per ASME Section VIII often mandate low-hydrogen processes for pressure-retaining welds. Any E6010 tack welds on pressure boundaries must be completely removed before final low-hydrogen welding.

A516 Gr.55/60

ASTM A516 Grades 55 and 60 are carbon steel plates designed for moderate and lower temperature pressure vessel service. Grade 55 (55 ksi tensile, 30 ksi yield) and Grade 60 (60 ksi tensile, 32 ksi yield) are widely used in storage tanks, heat exchangers, and process drums. Chemistry limits (0.24% max carbon for Gr.55, 0.27% max carbon for Gr.60 on thicker plate) and typical carbon equivalent of 0.38-0.44 qualify them for both Category A (non-low-hydrogen) and Category B preheat in Table 5.11. A516 is produced in plate thicknesses from 1/4" through 12". Grades 55 and 60 may be ordered as-rolled, normalized, or stress-relieved depending on the ASME Code requirements for the specific vessel design temperature and thickness.

Pourquoi ce Préchauffage pour A516 Gr.55/60 avec SMAW

Pressure vessel plate for storage tanks and heat exchangers at moderate strength. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 150°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Applications Typiques de A516 Gr.55/60

Specified for atmospheric storage tank shells per API 650, heat exchanger tube sheets, air receiver vessels, condensate drums, deaerator shells, and low-pressure separator vessels. A516 Gr.60 is the workhorse for ASME VIII Division 1 vessels under 650°F design temperature. Shell-to-head circumferential seams and nozzle reinforcement pads are the primary weld details. Plate thicknesses for API 650 tank shells typically range from 5/16" at the top course to 1" or more at the bottom course depending on tank diameter and liquid specific gravity. Vertical seam welds carry the full hydrostatic head and require complete joint penetration with radiographic examination. Tank diameters range from 15 feet for small day tanks to over 300 feet for crude oil terminal storage. Shop-welded vessel shells are rolled from flat plate with longitudinal seams welded first, then circumferential seams joining shell courses together on the vessel rotator.

Pourquoi le Préchauffage est Important à 3/4" to 1-1/2"

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

Autres Aciers avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2"

AcierCatégoriePréchauffage
A36A150°F (65°C)
A53 Gr.BA150°F (65°C)

A516 Gr.55/60 avec SMAW (non-low-hydrogen)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour A516 Gr.55/60 avec SMAW à 3/4" to 1-1/2" ?
Pour A516 Gr.55/60 soudé avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2" d'épaisseur, la température minimale de préchauffage est 150°F (65°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie A. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à A516 Gr.55/60 avec SMAW ?
A516 Gr.55/60 soudé avec SMAW (non-low-hydrogen) relève de la Catégorie A dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW non bas hydrogène. À 3/4" to 1-1/2" d'épaisseur, cette catégorie exige un préchauffage minimum de 150°F (65°C).
Pourquoi le préchauffage est-il de 150°F pour A516 Gr.55/60 à 3/4" to 1-1/2" ?
Le préchauffage de 150°F pour A516 Gr.55/60 à 3/4" to 1-1/2" avec SMAW (non-low-hydrogen) reflète la combinaison de la trempabilité de l'acier et la contrainte accrue à cette épaisseur.