AWS D1.1:2025 · Tableau 5.11 · Catégorie A

Préchauffage de A500 Gr.B/C pour SMAW (non-low-hydrogen) — 3/4" to 1-1/2"

Température minimale de préchauffage et entre passes pour A500 Gr.B/C soudé avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
150°F / 65°C
Catégorie A
Procédé SMAW non bas hydrogène
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For common structural shapes and plate, non-low-hydrogen SMAW with E6010 or E6011 excels at root passes on open-root groove welds where burn-through control matters. Vertical-up technique with a slight weave keeps the puddle manageable. Rod consumption runs about 10-12 electrodes per pound of weld metal deposited. Electrode stubs should be no shorter than 2 inches to maintain adequate arc length control.

A500 Gr.B/C

ASTM A500 Grade B (46 ksi yield for round, 42 ksi for rectangular) and Grade C (50 ksi round, 46 ksi rectangular) cover cold-formed welded and seamless structural tubing — round, square, and rectangular HSS sections. These are the standard tubular members in building frames, trusses, and signage structures, produced in wall thicknesses from 16 gauge (0.065") up to 5/8" for rectangular and 1/2" for round. Table 5.11 assigns both Category A and B preheat requirements. The cold-forming process work-hardens the corners, producing corner radii with higher hardness (up to 20% increase) and reduced ductility compared to the flat faces. This affects welding behavior at corner locations, particularly on heavily loaded connection details where weld starts or stops near corner radii can create initiation points for fatigue cracks.

Pourquoi ce Préchauffage pour A500 Gr.B/C avec SMAW

Cold-formed structural tubing for HSS sections in frames and trusses. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 150°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Applications Typiques de A500 Gr.B/C

Standard for HSS columns in office buildings, hollow section trusses in warehouse roofs, exposed architectural tube steel, sign structures, solar panel racking frames, greenhouse frames, and guard rail posts. A500 tube-to-tube moment connections require through-plate or diaphragm detailing to transfer forces across the closed section. Slotted gusset connections into HSS bracing members are a signature fabrication detail requiring careful fit-up and beveling of the gusset plate. Common sizes include HSS 6x6x3/8 and HSS 8x8x1/2 for columns, HSS 4x4x1/4 for bracing, and HSS 10x6x3/8 for rectangular beam applications. The cold-formed corner radius creates a heat-affected zone consideration that differs from hot-rolled shapes when planning multi-pass weld sequences. Round HSS pipe columns are also common, typically HSS 6.625x0.280 through HSS 12.750x0.500 for mezzanine posts and canopy supports. Fillet welds connecting HSS to cap plates and base plates are the most frequent weld joint detail.

Pourquoi le Préchauffage est Important à 3/4" to 1-1/2"

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

Autres Aciers avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2"

AcierCatégoriePréchauffage
A36A150°F (65°C)
A53 Gr.BA150°F (65°C)

A500 Gr.B/C avec SMAW (non-low-hydrogen)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour A500 Gr.B/C avec SMAW à 3/4" to 1-1/2" ?
Pour A500 Gr.B/C soudé avec SMAW (non-low-hydrogen) à 3/4" to 1-1/2" d'épaisseur, la température minimale de préchauffage est 150°F (65°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie A. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à A500 Gr.B/C avec SMAW ?
A500 Gr.B/C soudé avec SMAW (non-low-hydrogen) relève de la Catégorie A dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW non bas hydrogène. À 3/4" to 1-1/2" d'épaisseur, cette catégorie exige un préchauffage minimum de 150°F (65°C).
Pourquoi le préchauffage est-il de 150°F pour A500 Gr.B/C à 3/4" to 1-1/2" ?
Le préchauffage de 150°F pour A500 Gr.B/C à 3/4" to 1-1/2" avec SMAW (non-low-hydrogen) reflète la combinaison de la trempabilité de l'acier et la contrainte accrue à cette épaisseur.

Données de référence D1.1:2025. Non affilié à l'AWS.