AWS D1.1:2025 · Tableau 5.11 · Catégorie C

Préchauffage de A1066 Gr.70 pour SMAW (low-hydrogen) — over 2-1/2"

Température minimale de préchauffage et entre passes pour A1066 Gr.70 soudé avec SMAW (low-hydrogen) à over 2-1/2" d'épaisseur, selon AWS D1.1:2025 Tableau 5.11.

Basé sur AWS D1.1:2025 Tableau 5.11 — chaque valeur tracée à l'article.

Température Minimale de Préchauffage et Entre Passes
300°F / 150°C
Catégorie C
Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance)
AWS D1.1:2025 Tableau 5.11, §5.7
Outil de référence. Vérifier contre l'édition applicable au projet et DMOS approuvé par l'Ingénieur.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A1066 Gr.70

ASTM A1066 Grade 70 (70 ksi yield, 85 ksi minimum tensile) is the highest-strength grade in this specification, produced as quenched-and-tempered or TMCP plate for demanding bridge and structural applications. It falls under Category C in Table 5.11 but notably does not qualify for any H8 reduced-preheat category — unlike Grades 50/60/65, Grade 70 must use full Category C preheat regardless of consumable hydrogen designation. This distinction exists because the higher alloying level needed for 70 ksi yield pushes the CE-IIW to approximately 0.48-0.54, a range where even H8 hydrogen control is not sufficient to offset the hardenability-driven cracking risk at reduced preheat. Fabricators working with A1066 Gr.70 should budget for full Category C preheating time on every joint, with no H8 shortcut available.

Pourquoi ce Préchauffage pour A1066 Gr.70 avec SMAW-LH

Highest-strength A1066 at 70 ksi with no H8 preheat reduction available. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 300°F minimum with SMAW-LH, the preheat ensures the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material. Category C steels demand careful attention to interpass temperature control throughout the weld sequence.

Applications Typiques de A1066 Gr.70

Used in the most demanding bridge and structural applications: main girder flanges on record-span bridges, arch rib plates, suspension bridge stiffening truss chords, and heavy industrial crane runway girders. A1066 Gr.70 does not qualify for any H8 reduced preheat, so full Category C preheat must be applied regardless of consumable certification. This makes preheat management the primary production consideration for heavy-section joints where flange thicknesses of 2-4" are common. Fabrication bid costs for A1066 Gr.70 components must account for the full Category C preheat time in their labor estimates — typically 45-90 minutes per joint on plate over 2". Unlike Grades 50 and 60/65, there is no consumable-based path to reduce preheat duration on Gr.70 joints. Bridge fabrication shops working with this grade maintain dedicated preheat logs and temperature monitoring records for every CJP and PJP weld as part of their quality management system.

Pourquoi le Préchauffage est Important à over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Préchauffage Catégorie C pour A1066 Gr.70

La Catégorie C du Tableau 5.11 s'applique aux aciers à haute résistance où la combinaison de trempabilité et de contrainte résiduelle exige un préchauffage élevé. Pour A1066 Gr.70 à over 2-1/2", le préchauffage minimum de 300°F ralentit le taux de refroidissement de la soudure pour prévenir la formation de martensite susceptible de fissuration dans la zone affectée thermiquement.

Autres Aciers avec SMAW (low-hydrogen) à over 2-1/2"

AcierCatégoriePréchauffage
A36B225°F (110°C)
A53 Gr.BB225°F (110°C)
A106 Gr.BB225°F (110°C)
A633 Gr.EC300°F (150°C)

Essayez Différentes Combinaisons

Utilisez le calculateur interactif de préchauffage pour consulter toute combinaison acier, procédé et épaisseur du D1.1:2025 Tableau 5.11.

Quel est le préchauffage minimum pour A1066 Gr.70 avec SMAW-LH à over 2-1/2" ?
Pour A1066 Gr.70 soudé avec SMAW (low-hydrogen) à over 2-1/2" d'épaisseur, la température minimale de préchauffage est 300°F (150°C) selon AWS D1.1:2025 Tableau 5.11, Catégorie C. C'est aussi la température minimale entre passes.
Quelle catégorie du Tableau 5.11 s'applique à A1066 Gr.70 avec SMAW-LH ?
A1066 Gr.70 soudé avec SMAW (low-hydrogen) relève de la Catégorie C dans AWS D1.1:2025 Tableau 5.11. Procédé SMAW, SAW, GMAW ou FCAW bas hydrogène (aciers à haute résistance). À over 2-1/2" d'épaisseur, cette catégorie exige un préchauffage minimum de 300°F (150°C).
Pourquoi le préchauffage est-il de 300°F pour A1066 Gr.70 à over 2-1/2" ?
Le préchauffage de 300°F pour A1066 Gr.70 à over 2-1/2" avec SMAW (low-hydrogen) reflète la combinaison de la trempabilité de l'acier et la contrainte accrue à cette épaisseur.

Données de référence D1.1:2025. Non affilié à l'AWS.