AWS D1.1:2025 · Tabla 5.11 · Categoría B

Precalentamiento de A913 Gr.50/60/65 para SMAW (low-hydrogen) — up to 3/4"

Temperatura mínima de precalentamiento e interpaso para A913 Gr.50/60/65 soldado con SMAW (low-hydrogen) en espesor up to 3/4", según AWS D1.1:2025 Tabla 5.11.

Basado en AWS D1.1:2025 Tabla 5.11 — cada valor trazado a la cláusula.

Temperatura Mínima de Precalentamiento e Interpaso
32°F / 0°C
Categoría B
Proceso SMAW, SAW, GMAW o FCAW de bajo hidrógeno
AWS D1.1:2025 Tabla 5.11, §5.7
Cuando la temperatura del metal base es inferior a 32°F [0°C], precalentar a mínimo 70°F [20°C] y mantener durante la soldadura (Tabla 5.11 nota al pie a).
Herramienta de referencia. Verificar contra la edición aplicable al proyecto y WPS aprobada por el Ingeniero.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A913 Gr.50/60/65

ASTM A913 Grades 50 (50 ksi yield), 60 (60 ksi yield), and 65 (65 ksi yield) are quenched-and-self-tempered (QST) structural shapes produced by thermo-mechanical controlled processing (TMCP) — an in-line water quench immediately after the final rolling pass, followed by self-tempering from the core heat. This produces a fine-grained bainitic/ferritic microstructure throughout the full cross-section with carbon content typically 0.10-0.16% and CE-IIW of 0.35-0.42. Standard low-hydrogen processes use Category B; H8-certified consumables qualify for the reduced Category D (32°F all thicknesses), reflecting the inherent hydrogen cracking resistance of the TMCP microstructure. Available exclusively as W-shapes (primarily W14 heavy column sections), A913 is not produced as plate or other forms. The QST process eliminates the need for separate mill heat treatment, providing consistent through-thickness properties.

Por qué Este Precalentamiento para A913 Gr.50/60/65 con SMAW-LH

TMCP structural shapes for seismic frames with H8-eligible reduced preheat. This steel is prequalified only with low-hydrogen processes under Table 5.11, which is why it appears in Category B but not Category A. The 32°F minimum preheat with SMAW-LH balances the steel's strength level and carbon equivalent against the controlled hydrogen input from the consumable. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Aplicaciones Típicas de A913 Gr.50/60/65

Specified for seismic moment frame columns, high-rise building corner columns, transfer girder bearing seats, heavy truss chords, stadium cantilever support columns, and parking garage moment frame members. A913 TMCP shapes eliminate the need for post-rolling heat treatment, providing consistent through-thickness properties from flange tip to web center. Column splice CJP welds and beam-to-column continuity plate fillet welds are the critical weld joints. Available in W14 sections from W14x132 through W14x730, these shapes are the backbone of seismic column design in high-rise construction. The TMCP process creates a fine-grained microstructure throughout the full cross-section, unlike conventional heat-treated shapes that may have property gradients. The H8 path to Category D (32°F all thicknesses) offers significant fabrication cost savings on heavy column splices that would otherwise require 150-225°F preheat under Category B. Column flange thicknesses on W14x455 and heavier sections exceed 3".

Por qué el Precalentamiento Importa en up to 3/4"

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

Otros Aceros con SMAW (low-hydrogen) en up to 3/4"

AceroCategoríaPrecalentamiento
A36B32°F (0°C)
A633 Gr.EC50°F (10°C)
A709 HPS70WC50°F (10°C)
A710 Gr.AC50°F (10°C)

Prueba Diferentes Combinaciones

Usa la calculadora interactiva de precalentamiento para consultar cualquier combinación de acero, proceso y espesor de D1.1:2025 Tabla 5.11.

¿Cuál es el precalentamiento mínimo para A913 Gr.50/60/65 con SMAW-LH en up to 3/4"?
Para A913 Gr.50/60/65 soldado con SMAW (low-hydrogen) en espesor up to 3/4", la temperatura mínima de precalentamiento es 32°F (0°C) según AWS D1.1:2025 Tabla 5.11, Categoría B. Esta es también la temperatura mínima de interpaso — la junta no debe enfriarse por debajo de 32°F entre pasadas.
¿Qué categoría de la Tabla 5.11 aplica a A913 Gr.50/60/65 con SMAW-LH?
A913 Gr.50/60/65 soldado con SMAW (low-hydrogen) cae bajo la Categoría B en AWS D1.1:2025 Tabla 5.11. Proceso SMAW, SAW, GMAW o FCAW de bajo hidrógeno. En espesor up to 3/4", esta categoría requiere un precalentamiento mínimo de 32°F (0°C).
¿Necesita A913 Gr.50/60/65 precalentamiento en up to 3/4"?
En espesor up to 3/4" con SMAW (low-hydrogen), el precalentamiento mínimo es 32°F (0°C) — efectivamente temperatura ambiente sobre congelación. No se requiere precalentamiento activo a menos que el metal base esté por debajo de 32°F. Según la nota al pie (a) de la Tabla 5.11, si se trabaja bajo congelación, precalentar a al menos 70°F (20°C) y mantener durante la soldadura.