AWS D1.1:2025 · Tabla 5.11 · Categoría C

Precalentamiento de A709 HPS70W para GMAW — 1-1/2" to 2-1/2"

Temperatura mínima de precalentamiento e interpaso para A709 HPS70W soldado con GMAW en espesor 1-1/2" to 2-1/2", según AWS D1.1:2025 Tabla 5.11.

Basado en AWS D1.1:2025 Tabla 5.11 — cada valor trazado a la cláusula.

Temperatura Mínima de Precalentamiento e Interpaso
225°F / 110°C
Categoría C
Proceso SMAW, SAW, GMAW o FCAW de bajo hidrógeno (aceros de mayor resistencia)
AWS D1.1:2025 Tabla 5.11, §5.7
Herramienta de referencia. Verificar contra la edición aplicable al proyecto y WPS aprobada por el Ingeniero.

GMAW (Gas Metal Arc Welding)

GMAW (MIG) feeds continuous solid wire with shielding gas — an inherently low-hydrogen process assigned to Category B in Table 5.11.

On high-strength plate, GMAW wire selection must meet the specified minimum tensile to satisfy weld metal matching. ER80S-D2 or ER100S-G wires serve higher-strength steels. The inherently low hydrogen input of solid wire makes GMAW particularly well-suited for crack-sensitive TMCP grades where minimizing diffusible hydrogen is the primary fabrication objective.

A709 HPS70W

ASTM A709 HPS70W is the highest-strength weathering bridge steel with 70 ksi minimum yield and 85-110 ksi tensile range, used in long-span bridges and heavily loaded members where weight reduction is critical. Produced as quenched-and-tempered plate in thicknesses up to 4", its high strength places it in Category C of Table 5.11 with correspondingly higher preheat requirements. Table 5.11 footnote (b) sets a maximum preheat/interpass of 400°F for thickness up to 1-1/2” and 450°F for thicker material — this upper limit is unusual in D1.1 and exists because the Q&T microstructure can be degraded by excessive heat. The chemistry includes copper (0.25-0.40%), nickel (0.65-1.00%), and chromium (0.40-0.65%) for atmospheric corrosion resistance, with 0.19% max carbon keeping the CE-IIW in the 0.46-0.52 range.

Por qué Este Precalentamiento para A709 HPS70W con GMAW

Highest-strength 70 ksi weathering bridge steel for long-span applications. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 225°F minimum with GMAW, the preheat ensures the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material. Category C steels demand careful attention to interpass temperature control throughout the weld sequence.

Aplicaciones Típicas de A709 HPS70W

Reserved for long-span bridge main girder flanges, cable-stayed bridge edge girders, arch rib plates, high-load interchange ramp girders, and situations where reducing member depth saves clearance or reduces dead load. HPS70W enables weight savings of 20-30% versus conventional Gr.50 designs, allowing shallower girder sections that reduce embankment costs on grade-separation bridges. Flange thickness often exceeds 2”, making preheat and interpass control critical at every CJP splice and web-to-flange joint. Note that Table 5.11 footnote (b) sets maximum preheat and interpass limits of 400°F for thicknesses up to 1-1/2" and 450°F above. This upper limit is unusual in D1.1 and requires monitoring both minimum and maximum interpass throughout the welding sequence. Fabricators must use dual-readout temperature monitoring to ensure the joint stays within the qualified band. Filler metals must match the 70 ksi minimum tensile while providing weathering-compatible chemistry for exposed joints.

Por qué el Precalentamiento Importa en 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Precalentamiento Categoría C para A709 HPS70W

La Categoría C en la Tabla 5.11 aplica a aceros de mayor resistencia donde la combinación de templabilidad y tensión residual requiere un precalentamiento elevado. Para A709 HPS70W en 1-1/2" to 2-1/2", el precalentamiento mínimo de 225°F reduce la velocidad de enfriamiento de la soldadura para prevenir la formación de martensita susceptible al agrietamiento en la zona afectada por el calor.

Otros Aceros con GMAW en 1-1/2" to 2-1/2"

AceroCategoríaPrecalentamiento
A36B150°F (65°C)
A53 Gr.BB150°F (65°C)
A106 Gr.BB150°F (65°C)
A633 Gr.EC225°F (110°C)

Prueba Diferentes Combinaciones

Usa la calculadora interactiva de precalentamiento para consultar cualquier combinación de acero, proceso y espesor de D1.1:2025 Tabla 5.11.

¿Cuál es el precalentamiento mínimo para A709 HPS70W con GMAW en 1-1/2" to 2-1/2"?
Para A709 HPS70W soldado con GMAW en espesor 1-1/2" to 2-1/2", la temperatura mínima de precalentamiento es 225°F (110°C) según AWS D1.1:2025 Tabla 5.11, Categoría C. Esta es también la temperatura mínima de interpaso — la junta no debe enfriarse por debajo de 225°F entre pasadas.
¿Qué categoría de la Tabla 5.11 aplica a A709 HPS70W con GMAW?
A709 HPS70W soldado con GMAW cae bajo la Categoría C en AWS D1.1:2025 Tabla 5.11. Proceso SMAW, SAW, GMAW o FCAW de bajo hidrógeno (aceros de mayor resistencia). En espesor 1-1/2" to 2-1/2", esta categoría requiere un precalentamiento mínimo de 225°F (110°C).
¿Por qué el precalentamiento es 225°F para A709 HPS70W en 1-1/2" to 2-1/2"?
El precalentamiento de 225°F para A709 HPS70W en 1-1/2" to 2-1/2" con GMAW refleja la combinación de la templabilidad del acero y la restricción aumentada en este espesor. Un mayor precalentamiento reduce la velocidad de enfriamiento en la zona afectada por el calor, dando más tiempo al hidrógeno difusible para escapar.