AWS D1.1:2025 · Tabla 5.11 · Categoría A

Precalentamiento de A709 Gr.36 para SMAW (non-low-hydrogen) — over 2-1/2"

Temperatura mínima de precalentamiento e interpaso para A709 Gr.36 soldado con SMAW (non-low-hydrogen) en espesor over 2-1/2", según AWS D1.1:2025 Tabla 5.11.

Basado en AWS D1.1:2025 Tabla 5.11 — cada valor trazado a la cláusula.

Temperatura Mínima de Precalentamiento e Interpaso
300°F / 150°C
Categoría A
Proceso SMAW no bajo hidrógeno
AWS D1.1:2025 Tabla 5.11, §5.7
Herramienta de referencia. Verificar contra la edición aplicable al proyecto y WPS aprobada por el Ingeniero.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For common structural shapes and plate, non-low-hydrogen SMAW with E6010 or E6011 excels at root passes on open-root groove welds where burn-through control matters. Vertical-up technique with a slight weave keeps the puddle manageable. Rod consumption runs about 10-12 electrodes per pound of weld metal deposited. Electrode stubs should be no shorter than 2 inches to maintain adequate arc length control.

A709 Gr.36

ASTM A709 Grade 36 is the bridge-specific equivalent of A36, used exclusively for highway bridge construction under AASHTO LRFD Bridge Design Specifications. With 36 ksi minimum yield, 58-80 ksi tensile, and mandatory Charpy V-notch testing requirements based on AASHTO temperature zone (Zone 1: 70°F, Zone 2: 40°F, Zone 3: 10°F test temperatures), it qualifies for both Category A and Category B preheat in Table 5.11. Chemistry matches A36 (0.26% max carbon) but the CVN requirements add a fracture resistance guarantee absent from plain A36. A709 Gr.36 is primarily used for secondary bridge members — lateral bracing, floor beam stiffeners, diaphragm plates, and bearing components — where Gr.50 strength is not needed but bridge-code CVN compliance is required.

Por qué Este Precalentamiento para A709 Gr.36 con SMAW

Bridge-specific 36 ksi grade with CVN testing for highway construction. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Aplicaciones Típicas de A709 Gr.36

Specified exclusively for highway bridge deck plate, floor beams, lateral bracing, secondary framing, bridge railing posts, abutment bearing stiffeners, and diaphragm plates. A709 Gr.36 requires CVN testing per AASHTO zone classification, distinguishing it from plain A36 by guaranteeing fracture resistance at the bridge’s design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details in bridge shops. The fracture-critical designation on certain bridge members imposes additional NDT requirements (UT in lieu of RT for CJP welds) and welder qualification testing beyond standard D1.5 provisions. Temperature zones (1 through 3) determine the CVN test temperature for the Charpy specimens: Zone 1 at 70°F for moderate climates, Zone 2 at 40°F for cold climates, and Zone 3 at 10°F for severe cold. Mill certifications must show CVN results meeting the specified zone before plate release to the bridge fabricator.

Por qué el Precalentamiento Importa en over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Otros Aceros con SMAW (non-low-hydrogen) en over 2-1/2"

AceroCategoríaPrecalentamiento
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

Prueba Diferentes Combinaciones

Usa la calculadora interactiva de precalentamiento para consultar cualquier combinación de acero, proceso y espesor de D1.1:2025 Tabla 5.11.

¿Cuál es el precalentamiento mínimo para A709 Gr.36 con SMAW en over 2-1/2"?
Para A709 Gr.36 soldado con SMAW (non-low-hydrogen) en espesor over 2-1/2", la temperatura mínima de precalentamiento es 300°F (150°C) según AWS D1.1:2025 Tabla 5.11, Categoría A. Esta es también la temperatura mínima de interpaso — la junta no debe enfriarse por debajo de 300°F entre pasadas.
¿Qué categoría de la Tabla 5.11 aplica a A709 Gr.36 con SMAW?
A709 Gr.36 soldado con SMAW (non-low-hydrogen) cae bajo la Categoría A en AWS D1.1:2025 Tabla 5.11. Proceso SMAW no bajo hidrógeno. En espesor over 2-1/2", esta categoría requiere un precalentamiento mínimo de 300°F (150°C).
¿Por qué el precalentamiento es 300°F para A709 Gr.36 en over 2-1/2"?
El precalentamiento de 300°F para A709 Gr.36 en over 2-1/2" con SMAW (non-low-hydrogen) refleja la combinación de la templabilidad del acero y la restricción aumentada en este espesor. Un mayor precalentamiento reduce la velocidad de enfriamiento en la zona afectada por el calor, dando más tiempo al hidrógeno difusible para escapar.

Datos de referencia D1.1:2025. Sin afiliación con AWS.