AWS D1.1:2025 · Tabla 5.11 · Categoría A

Precalentamiento de A516 Gr.55/60 para SMAW (non-low-hydrogen) — over 2-1/2"

Temperatura mínima de precalentamiento e interpaso para A516 Gr.55/60 soldado con SMAW (non-low-hydrogen) en espesor over 2-1/2", según AWS D1.1:2025 Tabla 5.11.

Basado en AWS D1.1:2025 Tabla 5.11 — cada valor trazado a la cláusula.

Temperatura Mínima de Precalentamiento e Interpaso
300°F / 150°C
Categoría A
Proceso SMAW no bajo hidrógeno
AWS D1.1:2025 Tabla 5.11, §5.7
Herramienta de referencia. Verificar contra la edición aplicable al proyecto y WPS aprobada por el Ingeniero.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For pressure vessel plate, non-low-hydrogen SMAW is typically limited to non-pressure attachments and temporary fit-up clips. Code requirements per ASME Section VIII often mandate low-hydrogen processes for pressure-retaining welds. Any E6010 tack welds on pressure boundaries must be completely removed before final low-hydrogen welding.

A516 Gr.55/60

ASTM A516 Grades 55 and 60 are carbon steel plates designed for moderate and lower temperature pressure vessel service. Grade 55 (55 ksi tensile, 30 ksi yield) and Grade 60 (60 ksi tensile, 32 ksi yield) are widely used in storage tanks, heat exchangers, and process drums. Chemistry limits (0.24% max carbon for Gr.55, 0.27% max carbon for Gr.60 on thicker plate) and typical carbon equivalent of 0.38-0.44 qualify them for both Category A (non-low-hydrogen) and Category B preheat in Table 5.11. A516 is produced in plate thicknesses from 1/4" through 12". Grades 55 and 60 may be ordered as-rolled, normalized, or stress-relieved depending on the ASME Code requirements for the specific vessel design temperature and thickness.

Por qué Este Precalentamiento para A516 Gr.55/60 con SMAW

Pressure vessel plate for storage tanks and heat exchangers at moderate strength. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Aplicaciones Típicas de A516 Gr.55/60

Specified for atmospheric storage tank shells per API 650, heat exchanger tube sheets, air receiver vessels, condensate drums, deaerator shells, and low-pressure separator vessels. A516 Gr.60 is the workhorse for ASME VIII Division 1 vessels under 650°F design temperature. Shell-to-head circumferential seams and nozzle reinforcement pads are the primary weld details. Plate thicknesses for API 650 tank shells typically range from 5/16" at the top course to 1" or more at the bottom course depending on tank diameter and liquid specific gravity. Vertical seam welds carry the full hydrostatic head and require complete joint penetration with radiographic examination. Tank diameters range from 15 feet for small day tanks to over 300 feet for crude oil terminal storage. Shop-welded vessel shells are rolled from flat plate with longitudinal seams welded first, then circumferential seams joining shell courses together on the vessel rotator.

Por qué el Precalentamiento Importa en over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Otros Aceros con SMAW (non-low-hydrogen) en over 2-1/2"

AceroCategoríaPrecalentamiento
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

A516 Gr.55/60 con SMAW (non-low-hydrogen)

Prueba Diferentes Combinaciones

Usa la calculadora interactiva de precalentamiento para consultar cualquier combinación de acero, proceso y espesor de D1.1:2025 Tabla 5.11.

¿Cuál es el precalentamiento mínimo para A516 Gr.55/60 con SMAW en over 2-1/2"?
Para A516 Gr.55/60 soldado con SMAW (non-low-hydrogen) en espesor over 2-1/2", la temperatura mínima de precalentamiento es 300°F (150°C) según AWS D1.1:2025 Tabla 5.11, Categoría A. Esta es también la temperatura mínima de interpaso — la junta no debe enfriarse por debajo de 300°F entre pasadas.
¿Qué categoría de la Tabla 5.11 aplica a A516 Gr.55/60 con SMAW?
A516 Gr.55/60 soldado con SMAW (non-low-hydrogen) cae bajo la Categoría A en AWS D1.1:2025 Tabla 5.11. Proceso SMAW no bajo hidrógeno. En espesor over 2-1/2", esta categoría requiere un precalentamiento mínimo de 300°F (150°C).
¿Por qué el precalentamiento es 300°F para A516 Gr.55/60 en over 2-1/2"?
El precalentamiento de 300°F para A516 Gr.55/60 en over 2-1/2" con SMAW (non-low-hydrogen) refleja la combinación de la templabilidad del acero y la restricción aumentada en este espesor. Un mayor precalentamiento reduce la velocidad de enfriamiento en la zona afectada por el calor, dando más tiempo al hidrógeno difusible para escapar.

Datos de referencia D1.1:2025. Sin afiliación con AWS.