AASHTO/AWS D1.5:2025 · Tabelle 12.8 · Bruchkritisch

Vorwärmung HPS690W — 2.0–2.8 kJ/mm, 25–50 mm: 250–400°F

Bruchkritische Vorwärmanforderung für M270M HPS690W / M270 HPS100W bei 25–50 mm (1–2 in) Dicke, gemäß AASHTO/AWS D1.5:2025, dem Brückenschweißcode.

Basierend auf AWS D1.5:2025 — jeder Wert bis zur Klausel zurückverfolgt.

Bruchkritischer Vorwärmbereich
250–400°F / 120–200°C
Tabelle 12.8 — Wärmeeinbringung 2.0–2.8 kJ/mm bei 25–50 mm (1–2 in) Dicke
AASHTO/AWS D1.5M/D1.5:2025 Tabelle 12.8
Sowohl Mindest- ALS AUCH Höchstvorwärm-/Zwischenlagentemperatur müssen eingehalten werden. Überschreiten von 400°F gefährdet die Q&T-Mikrostruktur.
Referenzwerkzeug. Gegen projektanwendbare Ausgabe und von Ingenieur genehmigte WPS prüfen.

M270M HPS690W / M270 HPS100W

AASHTO M270M HPS690W (M270 HPS100W) is the highest-strength bridge steel at 690 MPa (100 ksi) yield, reserved for the most demanding long-span and cable-stayed bridge applications. It follows a completely different FC preheat table (Table 12.8) with min-max ranges and many prohibited thickness-heat input combinations marked with “—”. Table 12.8 requires H4 or H8 designated consumables; H16 is not permitted. NFC preheat per Table 6.3 Group 2; maximum interpass per Table 6.4 is 205°C (400°F) for material up to 40 mm, 230°C (450°F) above.

Wo M270M HPS690W / M270 HPS100W Eingesetzt Wird

Reserved for the most demanding long-span and cable-stayed bridge applications where maximum weight reduction justifies the material cost premium and fabrication complexity. Table 12.8 imposes both minimum AND maximum preheat limits, and many thickness-heat input combinations are outright prohibited. Fabricators must plan weld procedures around the permitted combinations before cutting plate. Filler metals must carry the H4 or H8 supplemental designator — H16 is not permitted for HPS690W FC applications.

M270M HPS690W / M270 HPS100W bei 25–50 mm (1–2 in)

HPS690W (HPS100W) at 40–65 mm is the thickest plate commonly used with this grade. Many thickness-heat input combinations at this tier are prohibited in Table 12.8 — the fabricator must verify that the planned welding procedure matches a permitted cell before beginning production. The permitted preheat ranges narrow further, often spanning only 50°F between minimum and maximum, making continuous temperature monitoring essential.

Min–Max Vorwärmkontrolle für M270M HPS690W / M270 HPS100W

Highest-strength 690 MPa (100 ksi) bridge steel with restricted FC combinations. Table 12.8 specifies a preheat RANGE of 250–400°F for this thickness and heat input combination. Unlike other FC grades, HPS690W requires both minimum AND maximum preheat control because the Q&T microstructure is sensitive to both excessive and insufficient heat. Many thickness-heat input combinations are prohibited ("—" in the table) because no safe preheat window exists — the steel cannot be reliably welded under those conditions.

Verschiedene Kombinationen Ausprobieren

Verwenden Sie den D1.5 Brücken-Vorwärmrechner für jeden AASHTO M270 Stahl, Wasserstoffniveau und Wärmeeinbringungskombination. Siehe auch den D1.1 Vorwärmrechner für Baustahl.

Was ist der Vorwärmbereich für HPS690W bei 25–50 mm (1–2 in) mit 2.0–2.8 kJ/mm?
D1.5 Tabelle 12.8 verlangt einen Vorwärmbereich von 250–400°F (120–200°C) für HPS690W bei 25–50 mm (1–2 in) mit 2.0–2.8 kJ/mm Wärmeeinbringung. Sowohl Minimum ALS AUCH Maximum müssen kontrolliert werden.
Warum hat HPS690W eine Vorwärm-Höchstgrenze?
HPS690W erreicht seine Festigkeit von 690 MPa (100 ksi) durch Vergüten. Übermäßige Vorwärmung kann die vergütete Mikrostruktur in der Wärmeeinflusszone erweichen. Die Höchstgrenze von 400°F (200°C) schützt diesen Q&T-Zustand.

D1.5:2025 Referenzdaten. Nicht mit AWS oder AASHTO verbunden.