AWS D1.1:2025 · Table 5.11 · Category G

A913 Gr.80 Preheat for SMAW-LH (H4) — over 2-1/2"

Per AWS D1.1:2025 Table 5.11, the minimum preheat for A913 Gr.80 welded with SMAW-LH (H4) at over 2-1/2" is 225°F (110°C), Category G. Preheat below this raises hydrogen-cracking risk in the heat-affected zone; the same temperature is the minimum interpass limit maintained through the weld.

Built on AWS D1.1:2025 Table 5.11 — every value traced to the clause.

Minimum Preheat & Interpass Temperature
225°F / 110°C
Category G H4-certified consumables — strictest hydrogen control
AWS D1.1:2025 Table 5.11, §5.7
This page shows preheat with H4-certified consumables. The H4 designation is stricter than H8 — no more than 4 mL of diffusible hydrogen per 100g of deposited weld metal, tested per AWS A4.3. A913 Gr.80 requires H4-certified consumables and cannot use standard low-hydrogen or H8 consumables for prequalified WPS under D1.1:2025 Table 5.11.
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

Have a preheat question? Ask Flux

SMAW-LH (H4) for A913 Gr.80 at over 2-1/2"

H4-certified SMAW-LH (H4) for A913 Gr.80 at over 2-1/2": minimum preheat 225°F (110°C) under Category G. H4 is the strictest hydrogen control in AWS, requiring 4 mL/100g maximum per A4.3. For E7018, only select manufacturing lots from specific producers consistently achieve H4 levels. The electrode must carry an explicit H4 designator — H8-certified rods do NOT automatically qualify as H4. Exposure time out of the oven should be limited to 2 hours maximum, more restrictive than the standard 4-hour limit.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, the Table 5.11 preheat category does not select the filler metal. Matching strength follows the steel's base-metal group in D1.1 Table 5.6: Table 5.7 lists AWS A5.1 carbon-steel electrodes such as E7018 for Group I and Group II base metals and marks A5.1 N/A for Groups III, IV and V, which take AWS A5.5 low-alloy electrodes such as E8018-C3 (Group III), E9018M (Group IV) or E10018M (Group V). Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

SMAW-LH Tips for High-Strength and TMCP Steels

For A913 Grade 80 TMCP shapes (80 ksi yield, Category G, H4 required exclusively), only H4-designated electrodes are prequalified — the E7018-H4 designation requires AWS A4.3 testing at 4 mL/100g maximum. Higher-strength electrodes (E8018-M-H4 or equivalent) may be needed to match 80 ksi yield. Rod oven temperature and exposure time rules per §7.3.2.1 and §7.3.2.4 are more critical on H4.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Why SMAW-LH (H4) for A913 Gr.80 at over 2-1/2"

Why SMAW-LH (H4) for A913 Gr.80 at over 2-1/2"? SMAW-LH (H4) delivers 3-5 lb/hr deposition — compared to <a href="/welding/preheat-calculator/a913-80/saw-h4/over-2-1-2-inch/">SAW (H4)</a> at 15-40 lb/hr. Position capability: all positions. Suitability: field and shop. The H4 designation provides the strictest hydrogen control available, which is mandatory for this steel grade under Table 5.11 — no other hydrogen level or standard low-hydrogen process is prequalified.

A913 Gr.80

The H4 requirement limits the available consumable pool significantly — only select electrode classifications carry the H4 designator. A913 Gr.80 availability is limited to heavy W14 column sections from a small number of domestic and international mills, with procurement lead times typically 16-24 weeks.

Why This Preheat for A913 Gr.80 with SMAW-LH

Highest-strength 80 ksi TMCP shape requiring H4 consumables exclusively. This steel requires H4-certified consumables — the strictest hydrogen control in Table 5.11 at no more than 4 mL diffusible hydrogen per 100g. At 225°F with SMAW-LH, the four thickness-dependent preheat tiers in Category G reflect the balance between the steel's 80 ksi yield strength and the exceptional hydrogen control provided by H4 certification. No other hydrogen designation is prequalified for this grade.

Typical Applications for A913 Gr.80

Reserved for the most demanding column applications in super-tall structures, typically interior gravity columns carrying 50+ stories of tributary load. A913 Gr.80 allows W14 sections to replace built-up box columns, simplifying connections and reducing fabrication cost while maintaining equivalent axial capacity. Every weld on this grade demands verified H4 consumables and documented preheat compliance — no exceptions or substitutions are permitted under Table 5.11. Column splice CJP welds require UT inspection per D1.1 Table 8.2. Only a limited number of domestic mills produce A913 Gr.80 shapes, with lead times of 16-24 weeks for non-stock sizes. The H4 consumable requirement eliminates most standard electrode inventory and requires dedicated electrode orders for each project. Fabricators must establish verified H4 supply chains before bidding Gr.80 column work, as H4-designated electrodes are not stocked by most welding distributors. Rejected consumable certifications can delay erection schedules by weeks.

Why Preheat Matters at over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

H4-Certified Consumables for A913 Gr.80

Category G is exclusive to A913 Gr.80 and requires H4-certified consumables — the strictest hydrogen control in D1.1 at no more than 4 mL of diffusible hydrogen per 100g of deposited weld metal. Standard low-hydrogen or H8 consumables are not prequalified for this grade.

What is the minimum preheat for A913 Gr.80 with SMAW-LH at over 2-1/2"?
When welding A913 Gr.80 at over 2-1/2" using SMAW-LH, the minimum preheat temperature is 225°F (110°C) per AWS D1.1:2025 Table 5.11, Category G. SMAW-LH places this combination in Category G. This is also the minimum interpass temperature — the joint must not cool below 225°F between passes.
What Table 5.11 category applies to A913 Gr.80 with SMAW-LH?
When using SMAW-LH on A913 Gr.80, the combination falls under Category G in AWS D1.1:2025 Table 5.11. H4-certified consumables — strictest hydrogen control. At over 2-1/2" thickness, Category G with SMAW-LH requires a minimum preheat of 225°F (110°C).
Why is preheat 225°F for A913 Gr.80 at over 2-1/2"?
The 225°F preheat for A913 Gr.80 at over 2-1/2" when using SMAW-LH reflects the combination of the steel's hardenability and the increased restraint at this thickness. SMAW-LH delivers controlled hydrogen levels, but at this thickness the preheat must slow the cooling rate in the heat-affected zone, giving diffusible hydrogen more time to escape before the steel transforms to a crack-susceptible microstructure.
What does H4 mean for welding A913 Gr.80?
The H4 supplementary designator certifies that the consumable deposits no more than 4 mL of diffusible hydrogen per 100g of deposited weld metal. For A913 Gr.80, using H4-certified SMAW-LH consumables qualifies for Category G with 225°F preheat at over 2-1/2", which may be lower than the standard low-hydrogen category.
How do I maintain preheat on very thick plate?
For material over 2-1/2”, preheat is typically applied with oxy-fuel torches or electric resistance blankets and monitored with contact thermometers or temp-sticks. The entire weld zone must reach the minimum temperature before welding begins, and interpass temperature is checked before each new pass. Insulating blankets help retain heat during pauses in multi-pass welding.

D1.1:2025 reference data. Not affiliated with AWS.