Preheat Heat Input Fillet Weld Size Deposition Rate Carbon Equivalent
AWS D1.1:2025 · Table 5.11 · Category B

A588 Preheat for FCAW — 1-1/2" to 2-1/2"

Minimum preheat and interpass temperature for A588 welded with FCAW at 1-1/2" to 2-1/2" thickness, per AWS D1.1:2025 Table 5.11.

Minimum Preheat & Interpass Temperature
150°F / 65°C
Category B
Low-hydrogen SMAW, SAW, GMAW, or FCAW process
AWS D1.1:2025 Table 5.11, §5.7
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

FCAW (Flux Cored Arc Welding)

FCAW uses tubular flux-cored wire, available gas-shielded (E71T-1) or self-shielded (E71T-8) for field work. Category B in Table 5.11.

E71T-1 gas-shielded wire is the workhorse for structural steel erection fillet welds. Self-shielded E71T-8 is preferred for field welding where wind makes gas shielding unreliable. Deposition rates run 8-12 lb/hr depending on wire diameter and position. The flux core provides a protective slag that supports the puddle in vertical-up and overhead positions.

A588

ASTM A588 is a weathering steel specification (50 ksi minimum yield, 70 ksi minimum tensile) that forms a protective iron oxide patina when exposed to atmospheric wet-dry cycling. The copper (0.25-0.40%), chromium (0.40-0.65%), and nickel (0.25-0.40%) alloying creates a dense, adherent rust layer that stabilizes after 2-5 years of exposure. Used in unpainted bridges and exposed structural members, it requires low-hydrogen processes (Category B) per Table 5.11 due to its higher alloy content pushing CE-IIW to 0.45-0.52. Weld filler metal must be a matching weathering composition (e.g., E8018-W2) to achieve corrosion-matching at exposed joints. A588 is produced as plate up to 8" thick and is available in structural shapes, though A709 Gr.50W is more commonly specified for bridge applications.

Why This Preheat for A588 with FCAW

Weathering steel forming protective patina for unpainted bridge applications. This steel is prequalified only with low-hydrogen processes under Table 5.11, which is why it appears in Category B but not Category A. The 150°F minimum preheat with FCAW balances the steel's strength level and carbon equivalent against the controlled hydrogen input from the consumable. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Typical Applications for A588

Used in unpainted highway bridge girders, exposed pedestrian bridges, architectural weathering facades, transmission tower legs, rail bridge stringers, and marine navigation light structures. A588 welds must use compatible weathering-type filler metals (e.g., E8018-W2 or ER80S-G) to achieve matching corrosion resistance in the exposed weld face. Girder flange splices and stiffener fillet welds are primary fabrication joints. The distinctive brown-orange patina develops over 2-5 years of atmospheric exposure to form a stable, adherent oxide layer that does not require repainting. In coastal locations with salt spray or in areas where the surface stays wet for extended periods, the protective oxide layer may not form properly, limiting A588 to inland applications with reliable wet-dry cycling. Bolt holes and copes must be deburred to prevent corrosion concentration. Drainage details in the steel design prevent water traps that would undermine the patina formation process.

Why Preheat Matters at 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Other Steels with FCAW at 1-1/2" to 2-1/2"

SteelCategoryPreheat
A36B150°F (65°C)
A633 Gr.EC225°F (110°C)
A709 HPS70WC225°F (110°C)
A710 Gr.AC225°F (110°C)

Try Different Combinations

Use the interactive preheat calculator to look up any steel, process, and thickness combination from D1.1:2025 Table 5.11.

What is the minimum preheat for A588 with FCAW at 1-1/2" to 2-1/2"?
For A588 welded with FCAW at 1-1/2" to 2-1/2" thickness, the minimum preheat temperature is 150°F (65°C) per AWS D1.1:2025 Table 5.11, Category B. This is also the minimum interpass temperature — the joint must not cool below 150°F between passes.
What Table 5.11 category applies to A588 with FCAW?
A588 welded with FCAW falls under Category B in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process. At 1-1/2" to 2-1/2" thickness, this category requires a minimum preheat of 150°F (65°C).
Why is preheat 150°F for A588 at 1-1/2" to 2-1/2"?
The 150°F preheat for A588 at 1-1/2" to 2-1/2" with FCAW reflects the combination of the steel's hardenability and the increased restraint at this thickness. Higher preheat slows the cooling rate in the heat-affected zone, giving diffusible hydrogen more time to escape before the steel transforms to a crack-susceptible microstructure.
What happens if I skip preheat on thick plate?
Without adequate preheat on material in the 1-1/2” to 2-1/2” range, the weld HAZ cools rapidly, trapping diffusible hydrogen in a hardened microstructure. This creates conditions for hydrogen-induced cracking (also called cold cracking or delayed cracking), which may not appear until hours or days after welding. Table 5.11 preheat minimums are set to prevent this failure mode.