AWS D1.1:2025 · Table 5.11 · Category B

A1066 Gr.50 Preheat for SMAW (low-hydrogen) — up to 3/4"

Per AWS D1.1:2025 Table 5.11, the minimum preheat for A1066 Gr.50 welded with SMAW (low-hydrogen) at up to 3/4" is 32°F (0°C), Category B. Preheat below this raises hydrogen-cracking risk in the heat-affected zone; the same temperature is the minimum interpass limit maintained through the weld.

Built on AWS D1.1:2025 Table 5.11 — every value traced to the clause.

Minimum Preheat & Interpass Temperature
32°F / 0°C
Category B Low-hydrogen SMAW, SAW, GMAW, or FCAW process
AWS D1.1:2025 Table 5.11, §5.7
When base metal temperature is below 32°F [0°C], preheat to minimum 70°F [20°C] and maintain during welding (Table 5.11 footnote a).
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

Have a preheat question? Ask Flux

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, the Table 5.11 preheat category does not select the filler metal. Matching strength follows the steel's base-metal group in D1.1 Table 5.6: Table 5.7 lists AWS A5.1 carbon-steel electrodes such as E7018 for Group I and Group II base metals and marks A5.1 N/A for Groups III, IV and V, which take AWS A5.5 low-alloy electrodes such as E8018-C3 (Group III), E9018M (Group IV) or E10018M (Group V). Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

SMAW-LH Tips for High-Strength and TMCP Steels

For A1066 Grade 50 HSLA plate (50 ksi yield, Category B or H8 Category E), E7018-H8 certified electrodes qualify for Category E preheat (50°F up to 1", 120°F above) — the H8 marking must appear on the rod package, not just the manufacturer literature. Standard E7018 (non-H8) falls under full Category B. SMAW-LH handles positional repair welds and connection details.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Filler Metal for SMAW-LH

Electrode: E7018 (AWS A5.1). Table 5.7 lists it for Group I and Group II base metals only; Groups III, IV and V take AWS A5.5 low-alloy electrodes from Table 5.7. Diameter: 1/8" (general/out-of-position), 5/32" (production), 3/16" (heavy plate flat only). Storage: 250°F rod oven minimum per D1.1 §7.3.2.1. Exposure limit: 4 hours out of oven per Table 7.1, then re-bake at 500-800°F for minimum 2 hours per §7.3.2.4 (A5.1 classification).

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

A1066 Gr.50

ASTM A1066 Grade 50 is a high-strength low-alloy plate (50 ksi yield, 65 ksi minimum tensile) with options for enhanced toughness and weldability through controlled chemistry and supplementary requirements. It falls under Category B for standard low-hydrogen processes and qualifies for the reduced Category E preheat (50°F up to 1”, 120°F above 1”) with H8-certified consumables. The specification includes S-series supplementary requirements for impact testing at various temperatures, allowing engineers to select the toughness grade appropriate for their service environment. Carbon content is limited to 0.20% max with CE-IIW controlled to approximately 0.38-0.44. A1066 Gr.50 competes with A572 Gr.50 plate in applications where the H8 preheat reduction provides meaningful fabrication cost savings on thick-section joints.

Why This Preheat for A1066 Gr.50 with SMAW-LH

HSLA plate with H8-eligible Category E reduced preheat option at 50 ksi. This steel is prequalified only with low-hydrogen processes under Table 5.11. With SMAW-LH, E7018 low-hydrogen electrodes produce typically 4-8 mL/100g diffusible hydrogen under proper rod oven conditions. The 32°F minimum preheat balances the steel’s strength level and carbon equivalent against the hydrogen control provided by SMAW-LH. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Typical Applications for A1066 Gr.50

Applied in bridge plate girder webs where enhanced toughness is required beyond A709 Gr.50, cold-region building plate elements, heavy equipment support platforms, wind turbine tower flanges, and modular building frames. A1066 Gr.50 with H8 consumables qualifies for Category E reduced preheat (50°F up to 1", 120°F above 1"), offering a cost advantage over standard Category B procedures on thick plate where preheat time is a significant production bottleneck. Plate procurement requires specifying the supplementary toughness requirements (S-series) appropriate for the service temperature — S30 for -30°F, S50 for -50°F testing. The H8 preheat reduction becomes increasingly valuable as plate thickness increases, saving 30-60 minutes of preheating time per joint on material over 1 inch. For a bridge fabricator welding 200+ stiffener fillet welds per girder, the cumulative preheat savings from H8 consumables can reduce shop cycle time by 15-20% compared to full Category B procedures.

Why Preheat Matters at up to 3/4"

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

Other Steels with SMAW (low-hydrogen) at up to 3/4"

SteelCategoryPreheat
A36B32°F (0°C)
A1066 Gr.60/65C50°F (10°C)
A1066 Gr.70C50°F (10°C)
A633 Gr.EC50°F (10°C)
What is the minimum preheat for A1066 Gr.50 with SMAW-LH at up to 3/4"?
When welding A1066 Gr.50 at up to 3/4" using SMAW-LH, the minimum preheat temperature is 32°F (0°C) per AWS D1.1:2025 Table 5.11, Category B. SMAW-LH places this combination in Category B. This is also the minimum interpass temperature — the joint must not cool below 32°F between passes.
What Table 5.11 category applies to A1066 Gr.50 with SMAW-LH?
When using SMAW-LH on A1066 Gr.50, the combination falls under Category B in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process. At up to 3/4" thickness, Category B with SMAW-LH requires a minimum preheat of 32°F (0°C).
Does A1066 Gr.50 need preheat at up to 3/4"?
When welding with SMAW-LH at up to 3/4" thickness, the minimum preheat is 32°F (0°C) — effectively ambient temperature above freezing. SMAW-LH with this steel requires no active preheating unless the base metal is below 32°F. Per Table 5.11 footnote (a), if working below freezing, preheat to at least 70°F (20°C) and maintain during welding.
Is preheat needed for plate under 3/4 inch?
For most structural steels at this thickness, the Table 5.11 minimum is 32°F (0°C) — ambient temperature above freezing. The thin cross-section allows hydrogen to diffuse out readily. Per footnote (a), if working below freezing, preheat to at least 70°F (20°C) and maintain during welding.

D1.1:2025 reference data. Not affiliated with AWS.