Preheat Heat Input Fillet Weld Size Deposition Rate Carbon Equivalent
AWS D1.1:2025 · Table 5.11 · Category B

A106 Gr.B Preheat for SMAW (low-hydrogen) — 1-1/2" to 2-1/2"

Minimum preheat and interpass temperature for A106 Gr.B welded with SMAW (low-hydrogen) at 1-1/2" to 2-1/2" thickness, per AWS D1.1:2025 Table 5.11.

Minimum Preheat & Interpass Temperature
150°F / 65°C
Category B
Low-hydrogen SMAW, SAW, GMAW, or FCAW process
AWS D1.1:2025 Table 5.11, §5.7
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For pipe butt joints, E7018 fill and cap passes follow the E6010 root. Vertical-down technique is not permitted with low-hydrogen electrodes. Interpass cleaning requires chipping and wire brushing between every pass to remove slag inclusions. Restart craters should be ground to sound metal before striking a new arc.

A106 Gr.B

ASTM A106 Grade B covers seamless carbon steel pipe for high-temperature service up to about 750°F, with 35 ksi minimum yield and 60 ksi minimum tensile strength. Produced in sizes from 1/4" through 30" NPS, it is the standard pipe material for power plants, refineries, and process piping where elevated temperature and pressure coexist. Chemistry limits (0.30% max carbon, 0.29-1.06% manganese) give it a weldability profile that matches common structural grades with Category A and B preheat requirements. A106 is exclusively seamless, which eliminates the ERW seam concern present in A53. Grade C (40 ksi yield) exists but Grade B handles the vast majority of process piping service.

Why This Preheat for A106 Gr.B with SMAW-LH

Seamless pipe rated for high-temperature service up to 750°F. With low-hydrogen SMAW-LH, this combination falls under Category B rather than Category A, reflecting the lower hydrogen potential of the consumable. The 150°F minimum preheat is lower than what non-low-hydrogen SMAW would require at the same thickness. Low-hydrogen electrodes and inherently low-hydrogen wire processes reduce the driving force for hydrogen-induced cracking in the heat-affected zone.

Typical Applications for A106 Gr.B

Used in boiler steam headers, refinery piping racks, process plant branch connections, heat exchanger nozzle welds, power plant main steam lines, petrochemical reactor feed piping, and high-temperature manifolds. A106 Gr.B butt welds in process piping require joint preparation to B31.1 (power piping) or B31.3 (process piping) depending on service classification. Socket welds on small-bore A106 drain lines and instrument take-offs are common in utility stations, typically 1/2" to 2" NPS. Typical wall thicknesses range from Schedule 40 (0.237" wall on 2" NPS) to Schedule 160 (0.500" wall on 4" NPS) in critical high-energy service. Weld procedure qualification often includes side bend tests and tensile tests specific to the pipe diameter and wall thickness being joined. Field welds at pipe-to-flange connections and valve set-on joints require portable preheating equipment when wall thickness exceeds 1/2".

Why Preheat Matters at 1-1/2" to 2-1/2"

Heavy plate with significant restraint and thermal mass — preheat is critical to maintain slow cooling for hydrogen escape.

Other Steels with SMAW (low-hydrogen) at 1-1/2" to 2-1/2"

SteelCategoryPreheat
A36B150°F (65°C)
A633 Gr.EC225°F (110°C)
A709 HPS70WC225°F (110°C)
A710 Gr.AC225°F (110°C)

A106 Gr.B with SMAW (low-hydrogen)

Try Different Combinations

Use the interactive preheat calculator to look up any steel, process, and thickness combination from D1.1:2025 Table 5.11.

What is the minimum preheat for A106 Gr.B with SMAW-LH at 1-1/2" to 2-1/2"?
For A106 Gr.B welded with SMAW (low-hydrogen) at 1-1/2" to 2-1/2" thickness, the minimum preheat temperature is 150°F (65°C) per AWS D1.1:2025 Table 5.11, Category B. This is also the minimum interpass temperature — the joint must not cool below 150°F between passes.
What Table 5.11 category applies to A106 Gr.B with SMAW-LH?
A106 Gr.B welded with SMAW (low-hydrogen) falls under Category B in AWS D1.1:2025 Table 5.11. Low-hydrogen SMAW, SAW, GMAW, or FCAW process. At 1-1/2" to 2-1/2" thickness, this category requires a minimum preheat of 150°F (65°C).
Why is preheat 150°F for A106 Gr.B at 1-1/2" to 2-1/2"?
The 150°F preheat for A106 Gr.B at 1-1/2" to 2-1/2" with SMAW (low-hydrogen) reflects the combination of the steel's hardenability and the increased restraint at this thickness. Higher preheat slows the cooling rate in the heat-affected zone, giving diffusible hydrogen more time to escape before the steel transforms to a crack-susceptible microstructure.
What happens if I skip preheat on thick plate?
Without adequate preheat on material in the 1-1/2” to 2-1/2” range, the weld HAZ cools rapidly, trapping diffusible hydrogen in a hardened microstructure. This creates conditions for hydrogen-induced cracking (also called cold cracking or delayed cracking), which may not appear until hours or days after welding. Table 5.11 preheat minimums are set to prevent this failure mode.

D1.1:2025 reference data. Not affiliated with AWS.