AASHTO/AWS D1.5:2025 · Table 12.8 · Fracture-Critical

M270M HPS690W Preheat — ≥ 3.6 kJ/mm, 13–20 mm: N/A

Fracture-critical preheat requirement for M270M HPS690W / M270 HPS100W at 13–20 mm (1/2–3/4 in) thickness, per AASHTO/AWS D1.5:2025, the Bridge Welding Code.

Fracture-Critical Preheat Status
NOT PERMITTED
Table 12.8 — ≥ 3.6 kJ/mm heat input at 13–20 mm (1/2–3/4 in) thickness
AASHTO/AWS D1.5M/D1.5:2025 Table 12.8
This thickness and heat input combination is marked "—" in Table 12.8. Adjust welding parameters or joint geometry.
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

M270M HPS690W / M270 HPS100W

AASHTO M270M HPS690W (M270 HPS100W) is the highest-strength bridge steel at 690 MPa (100 ksi) yield, reserved for the most demanding long-span and cable-stayed bridge applications. It follows a completely different FC preheat table (Table 12.8) with min-max ranges and many prohibited thickness-heat input combinations marked with “—”. Table 12.8 requires H4 or H8 designated consumables; H16 is not permitted. NFC preheat per Table 6.3 Group 2; maximum interpass per Table 6.4 is 205°C (400°F) for material up to 40 mm, 230°C (450°F) above.

Understanding the FC Preheat for M270M HPS690W / M270 HPS100W

Highest-strength 690 MPa (100 ksi) bridge steel with restricted FC combinations. This thickness and heat input combination is marked "—" (not permitted) in Table 12.8. No preheat temperature exists that simultaneously prevents hydrogen-induced cracking and avoids degrading the 690 MPa Q&T microstructure. The fabricator must adjust either the heat input (by changing welding parameters) or use a different joint geometry that allows a thinner effective section.

Where M270M HPS690W / M270 HPS100W Is Used

Reserved for the most demanding long-span and cable-stayed bridge applications where maximum weight reduction justifies the material cost premium and fabrication complexity. Table 12.8 imposes both minimum AND maximum preheat limits, and many thickness-heat input combinations are outright prohibited. Fabricators must plan weld procedures around the permitted combinations before cutting plate. Filler metals must carry the H4 or H8 supplemental designator — H16 is not permitted for HPS690W FC applications.

M270M HPS690W / M270 HPS100W at 13–20 mm (1/2–3/4 in)

HPS690W (HPS100W) at up to 20 mm is used in deck plate and stiffener components on orthotropic steel deck bridges — specialized long-span applications where the 100 ksi yield enables very thin plate to carry traffic loads. Table 12.8 requires both min and max preheat even at this thin section, and several heat input combinations are prohibited. Only H4 or H8 consumables are permitted; H16 is not allowed at any thickness.

Why This Combination Is Prohibited

Highest-strength 690 MPa (100 ksi) bridge steel with restricted FC combinations. This thickness and heat input combination is marked "—" (not permitted) in Table 12.8. No preheat temperature exists that simultaneously prevents hydrogen-induced cracking and avoids degrading the 690 MPa Q&T microstructure. The fabricator must adjust either the heat input (by changing welding parameters) or use a different joint geometry that allows a thinner effective section.

M270M HPS690W / M270 HPS100W at ≥ 3.6 kJ/mm

Try Different Combinations

Use the D1.5 Bridge Preheat Calculator to look up any AASHTO M270 steel, hydrogen level, and heat input combination. Also see the D1.1 Preheat Calculator for structural steel.

Can HPS690W be welded at 13–20 mm (1/2–3/4 in) with ≥ 3.6 kJ/mm heat input?

No — this combination is marked "—" (not permitted) in D1.5 Table 12.8. No preheat temperature exists that simultaneously prevents hydrogen cracking and avoids degrading the 690 MPa quenched-and-tempered microstructure at these parameters. Adjust the heat input or joint geometry.

What heat input ranges are permitted for HPS690W at this thickness?

Table 12.8 permits only specific thickness-heat input combinations. Check the calculator for permitted ranges at 13–20 mm (1/2–3/4 in). Generally, thicker sections require higher heat input to access permitted combinations.

D1.5:2025 reference data. Not affiliated with AWS or AASHTO.