AASHTO/AWS D1.5:2025 · Table 12.6/12.7 · Fracture-Critical · H4

M270M HPS345W Preheat — H4, High HI, 20–40 mm: 150°F

Fracture-critical preheat requirement for M270M HPS345W / M270 HPS50W at 20–40 mm (3/4–1½ in) thickness with H4 hydrogen designation, per AASHTO/AWS D1.5:2025, the Bridge Welding Code.

Fracture-Critical Minimum Preheat & Interpass
150°F / 70°C
H4 hydrogen · > 2.8 kJ/mm heat input · 20–40 mm (3/4–1½ in) thickness
AASHTO/AWS D1.5M/D1.5:2025 Table 12.6/12.7
H4 designation: consumable deposits ≤ 4 mL/100g diffusible hydrogen per AWS A4.3. Lower hydrogen = lower preheat requirement.
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

M270M HPS345W / M270 HPS50W

AASHTO M270M HPS345W (M270 HPS50W) is a high-performance weathering bridge steel with enhanced weldability through controlled chemistry — 0.11% max carbon, 0.006% max sulfur with calcium treatment for inclusion shape control. Developed under FHWA-funded research to eliminate the lamellar tearing and inconsistent toughness problems of earlier weathering steel bridge designs. The lower carbon equivalent compared to conventional Gr.345W reduces cracking sensitivity at flange splices. NFC preheat per Table 6.3 Group 1; FC per Tables 12.6/12.7.

Understanding the FC Preheat for M270M HPS345W / M270 HPS50W

High-performance weathering 345 MPa steel with enhanced weldability. Under D1.5 fracture-critical requirements (Clause 12), the combination of H4 hydrogen designation and this heat input band requires 150°F minimum preheat at 20–40 mm (3/4–1½ in). Lower hydrogen levels (H4 < H8 < H16) allow lower preheat because less hydrogen enters the weld deposit. Similarly, higher heat input reduces preheat requirements because slower cooling rates give hydrogen more time to diffuse out.

Where M270M HPS345W / M270 HPS50W Is Used

Preferred over conventional Gr.345W for new unpainted bridge construction. The HPS designation indicates FHWA-developed chemistry with 0.11% max carbon and controlled sulfur for enhanced weldability and lamellar tearing resistance. Flange splice CJP welds benefit from the lower carbon equivalent, reducing reject rates during cold-weather bridge fabrication. Material cost premium over standard Gr.345W is typically 15–25% per ton but eliminates weldability-related rework.

H4 Hydrogen Control for M270M HPS345W / M270 HPS50W

HPS345W (HPS50W) already has inherently low carbon equivalent due to HPS chemistry control. Combined with H4 consumables, the preheat requirement drops to the lowest tier in Tables 12.6/12.7 — frequently 20–30°F lower than conventional 345W, compounding the weldability advantage of HPS chemistry with optimized hydrogen control.

Why Preheat Matters at 20–40 mm (3/4–1½ in)

Material from 20 to 40 mm (3/4 to 1-1/2 in) includes many girder web plates, splice plates, and bearing stiffener plates. Preheat increases to 20°C (70°F) for Group 1 and 50°C (125°F) for Group 2 under Table 6.3. The thicker section slows hydrogen diffusion, requiring higher preheat to maintain safe cooling rates.

M270M HPS345W / M270 HPS50W at 20–40 mm (3/4–1½ in)

At 20–40 mm, HPS345W (HPS50W) appears in splice plates and web plates for new unpainted bridge construction. The calcium-treated, inclusion-shape-controlled chemistry virtually eliminates lamellar tearing at through-thickness-loaded connections — a critical advantage for corner joints at bearing stiffener-to-flange connections where Z-direction tensile stresses develop during welding contraction.

H4-Certified Consumables for FC Bridge Welding

The H4 supplementary designator certifies that the consumable deposits no more than 4 mL of diffusible hydrogen per 100g of deposited weld metal. For fracture-critical M270M HPS345W / M270 HPS50W at 20–40 mm (3/4–1½ in) thickness with > 2.8 kJ/mm heat input, H4 consumables achieve the lowest preheat of 150°F (70°C) in the FC tables. This is the preferred hydrogen level when preheat reduction is a priority.

Other Bridge Steels at H4 > 2.8 kJ/mm · 20–40 mm (3/4–1½ in)

SteelTablePreheat
M270M Gr.250 / M270 Gr.36A100°F (40°C)
M270M Gr.345 / M270 Gr.50A100°F (40°C)
M270M Gr.345S / M270 Gr.50SA100°F (40°C)
M270M Gr.345W / M270 Gr.50WB150°F (70°C)

Try Different Combinations

Use the D1.5 Bridge Preheat Calculator to look up any AASHTO M270 steel, hydrogen level, and heat input combination. Also see the D1.1 Preheat Calculator for structural steel.

What is the FC preheat for M270M HPS345W / M270 HPS50W with H4 at 20–40 mm (3/4–1½ in)?

For fracture-critical M270M HPS345W / M270 HPS50W welded with H4-designated consumables at 20–40 mm (3/4–1½ in) thickness and > 2.8 kJ/mm heat input, the minimum preheat is 150°F (70°C) per D1.5 Table 12.6/12.7.

What is the difference between FC and NFC preheat for M270M HPS345W / M270 HPS50W?

Non-fracture-critical (Table 6.3) preheat is a simple thickness-based lookup. Fracture-critical (Tables 12.4–12.8) adds hydrogen level and heat input as variables, typically requiring higher preheat. For FC members, the hydrogen designator on the consumable classification directly determines the minimum preheat.

How does heat input affect preheat for FC M270M HPS345W / M270 HPS50W?

Higher heat input means slower cooling rates, giving hydrogen more time to diffuse out of the weld zone. At > 2.8 kJ/mm, the 150°F preheat balances the hydrogen level and cooling rate. Moving to a higher heat input band would typically reduce the required preheat for the same hydrogen level and thickness.

Why does Group 2 need higher preheat than Group 1 at this thickness?

Group 2 steels (HPS485W, HPS690W) have higher hardenability from their increased alloy content, forming harder microstructures on cooling. The 50°C (125°F) minimum versus Group 1’s 20°C (70°F) compensates for the greater cracking susceptibility of these higher-strength grades.