AASHTO/AWS D1.5:2025 · Table 12.4/12.5 · Fracture-Critical · H8

M270M Gr.250 Preheat — H8, High HI, 40<t≤60 mm: 80°C

Fracture-critical preheat requirement for M270M Gr.250 / M270 Gr.36 at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in thickness with H8 hydrogen designation, per AASHTO/AWS D1.5:2025, the Bridge Welding Code.

Built on AWS D1.5:2025 — every value traced to the clause.

Fracture-Critical Minimum Preheat & Interpass
175°F / 80°C
H8 hydrogen · HI > 2.8 kJ/mm; HI > 70 kJ/in heat input · 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in thickness
AASHTO/AWS D1.5M/D1.5:2025 Table 12.4/12.5
H8 designation: consumable deposits ≤ 8 mL/100g diffusible hydrogen per AWS A4.3. Lower hydrogen = lower preheat requirement.
Reference tool. Verify against project-applicable edition and Engineer-approved WPS.

M270M Gr.250 / M270 Gr.36

AASHTO M270M Gr.250 (M270 Gr.36) is the basic structural bridge steel grade. It is the direct bridge equivalent of ASTM A709 Gr.36, procured under AASHTO M270 with mandatory Charpy V-notch testing per temperature zone. Used for secondary bridge members — lateral bracing, diaphragm plates, floor beam stiffeners, and bearing components where Gr.345 strength is not needed. Non-fracture-critical preheat follows Table 6.3 Group 1; fracture-critical follows Tables 12.4/12.5 with hydrogen and heat input as additional variables.

Understanding the FC Preheat for M270M Gr.250 / M270 Gr.36

M270M Gr.250 / M270 Gr.36. For H8 at 1-1/2 < t ≤ 2-1/2 in, the selected fracture-critical cell requires 175°F minimum preheat. Check the cell again if the thickness, hydrogen designation, or heat input changes.

Where M270M Gr.250 / M270 Gr.36 Is Used

Specified for secondary bridge members under AASHTO LRFD — lateral bracing angles, diaphragm plates, floor beam stiffeners, bearing seat components, and railing posts. Gr.250 (36) requires CVN testing per AASHTO temperature zone, distinguishing it from plain ASTM A36 by guaranteeing fracture resistance at the bridge design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details. Temperature zones determine CVN testing conditions; retain the zone assignment and toughness-test certificate with mill records, and check the contract’s fracture-critical member designation.

H8 Hydrogen Control for M270M Gr.250 / M270 Gr.36

H8 designation (8 mL/100g max) on Gr.250 (36) provides a balanced approach between preheat economy and consumable availability. Most structural SMAW electrodes and FCAW wires carry H8 classification as the standard low-hydrogen tier. For secondary bridge members, H8 is typically the default specification unless the Engineer specifically mandates H4.

Why Preheat Matters at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in

The selected thickness interval is 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in. Use its own fracture-critical table row; non-fracture-critical thickness bands do not select this result. Table 12.4/12.5 requires a minimum preheat/interpass temperature of 175°F (80°C) for this combination. Apply the value for the selected hydrogen designation and heat input.

M270M Gr.250 / M270 Gr.36 at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in

Gr.250 (36) at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in is uncommon in modern designs because Gr.345 handles the same loads at lighter weight. When specified, it appears in bearing seats and massive foundation assemblies where material cost is secondary to simplicity. At this thickness the HAZ cooling rate is significantly slower, and the 175°F (80°C) preheat reflects the need to keep cooling rates below the critical rate for hydrogen-induced cracking in the coarse-grained HAZ.

What is the FC preheat for M270M Gr.250 / M270 Gr.36 with H8 at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in?
For fracture-critical M270M Gr.250 / M270 Gr.36 welded with H8-designated consumables at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in thickness and HI > 2.8 kJ/mm; HI > 70 kJ/in heat input, the minimum preheat is 175°F (80°C) per D1.5 Table 12.4/12.5.
What is the difference between FC and NFC preheat for M270M Gr.250 / M270 Gr.36?
Non-fracture-critical (Table 6.3) preheat is a simple thickness-based lookup. Fracture-critical (Tables 12.4–12.8) adds hydrogen level and heat input as variables, typically requiring higher preheat. For FC members, the hydrogen designator on the consumable classification directly determines the minimum preheat.
How does heat input affect preheat for FC M270M Gr.250 / M270 Gr.36?
Higher heat input means slower cooling rates, giving hydrogen more time to diffuse out of the weld zone. At HI > 70 kJ/in, the 175°F preheat balances the hydrogen level and cooling rate. Moving to a higher heat input band would typically reduce the required preheat for the same hydrogen level and thickness.
What temperature applies to M270M Gr.250 / M270 Gr.36 at 40 < t ≤ 60 mm; 1-1/2 < t ≤ 2-1/2 in?
Table 12.4/12.5 requires a minimum preheat/interpass temperature of 175°F (80°C) for this combination. Apply the value for the selected hydrogen designation and heat input.

D1.5:2025 reference data. Not affiliated with AWS or AASHTO.