AWS D1.1:2025 · Tabela 5.11 · Categoria B

Pré-aquecimento de A992 para SMAW (low-hydrogen) — 3/4" to 1-1/2"

Temperatura mínima de pré-aquecimento e interpasse para A992 soldado com SMAW (low-hydrogen) em espessura 3/4" to 1-1/2", conforme AWS D1.1:2025 Tabela 5.11.

Baseado na AWS D1.1:2025 Tabela 5.11 — cada valor rastreado à cláusula.

Temperatura Mínima de Pré-aquecimento e Interpasse
50°F / 10°C
Categoria B
Processo SMAW, SAW, GMAW ou FCAW de baixo hidrogênio
AWS D1.1:2025 Tabela 5.11, §5.7
Ferramenta de referência. Verificar contra a edição aplicável ao projeto e EPS aprovada pelo Engenheiro.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

E7018 is the default electrode for structural fillet and groove welds on common building steels. Rod ovens should hold at a minimum of 250°F per D1.1 Clause 7.3.2.1; exposure time out of the oven is limited to 4 hours maximum per Table 7.1. For overhead position, use 3/32" diameter rods to control puddle size. Vertical-up stringer beads provide the best fusion on thicker members.

A992

ASTM A992 (50 ksi minimum yield, 65 ksi maximum yield, 65 ksi minimum tensile) is the standard specification for W-shapes in building construction — virtually all wide-flange beams and columns in US structural steel buildings are A992. The specification was created in 1998 to address weldability concerns with earlier A36/A572 shapes by imposing tighter chemistry controls: 0.23% max carbon, 0.15% max combined V+Cb+N, and a 0.85 maximum yield-to-tensile ratio to ensure ductile behavior in seismic connections. These controls produce a typical CE-IIW of 0.38-0.44. It falls under Category B in Table 5.11, requiring low-hydrogen welding processes. Most domestic W-shapes are dual-certified A992/A572 Gr.50, with actual mill test yields typically 50-58 ksi. The controlled chemistry makes A992 the most weldable 50 ksi structural shape available.

Por que Este Pré-aquecimento para A992 com SMAW-LH

Standard W-shape specification for virtually all US building wide-flanges. This steel is prequalified only with low-hydrogen processes under Table 5.11, which is why it appears in Category B but not Category A. The 50°F minimum preheat with SMAW-LH balances the steel's strength level and carbon equivalent against the controlled hydrogen input from the consumable. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Aplicações Típicas de A992

The universal W-shape steel for building frames: beam-to-column moment connections, simple shear tabs, column web doubler plates, continuity plates, collector beams in lateral systems, drag struts, transfer beams, and composite deck stud rails. A992 chemistry control (max 0.23% carbon, max 0.15% V-Cb-N) was specifically designed to improve weldability over earlier A36/A572 shapes after the 1994 Northridge earthquake revealed brittle fracture problems in welded steel moment frames. Flange CJP welds in seismic moment frames are the highest-criticality joints in US building construction. The controlled yield-to-tensile ratio (max 0.85) ensures ductile behavior in seismic connections by guaranteeing sufficient strain hardening capacity. Mill test reports for A992 shapes routinely show actual yield strengths of 50-55 ksi, well above the 50 ksi minimum. The weld access hole geometry per AISC 358 is dimensioned specifically for A992 flanges to reduce stress concentrations at the CJP weld termination.

Por que o Pré-aquecimento Importa em 3/4" to 1-1/2"

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

Outros Aços com SMAW (low-hydrogen) em 3/4" to 1-1/2"

AçoCategoriaPré-aquecimento
A36B50°F (10°C)
A633 Gr.EC150°F (65°C)
A709 HPS70WC150°F (65°C)
A710 Gr.AC150°F (65°C)

Experimente Diferentes Combinações

Use a calculadora interativa de pré-aquecimento para consultar qualquer combinação de aço, processo e espessura da D1.1:2025 Tabela 5.11.

Qual é o pré-aquecimento mínimo para A992 com SMAW-LH em 3/4" to 1-1/2"?
Para A992 soldado com SMAW (low-hydrogen) em espessura 3/4" to 1-1/2", a temperatura mínima de pré-aquecimento é 50°F (10°C) conforme AWS D1.1:2025 Tabela 5.11, Categoria B. Esta é também a temperatura mínima de interpasse.
Qual categoria da Tabela 5.11 se aplica a A992 com SMAW-LH?
A992 soldado com SMAW (low-hydrogen) se enquadra na Categoria B da AWS D1.1:2025 Tabela 5.11. Processo SMAW, SAW, GMAW ou FCAW de baixo hidrogênio. Em espessura 3/4" to 1-1/2", esta categoria requer pré-aquecimento mínimo de 50°F (10°C).

Dados de referência D1.1:2025. Sem afiliação com AWS.