AWS D1.1:2025 · Tabela 5.11 · Categoria B

Pré-aquecimento de A913 Gr.50/60/65 para SAW — up to 3/4"

Temperatura mínima de pré-aquecimento e interpasse para A913 Gr.50/60/65 soldado com SAW em espessura up to 3/4", conforme AWS D1.1:2025 Tabela 5.11.

Baseado na AWS D1.1:2025 Tabela 5.11 — cada valor rastreado à cláusula.

Temperatura Mínima de Pré-aquecimento e Interpasse
32°F / 0°C
Categoria B
Processo SMAW, SAW, GMAW ou FCAW de baixo hidrogênio
AWS D1.1:2025 Tabela 5.11, §5.7
Quando a temperatura do metal de base está abaixo de 32°F [0°C], pré-aquecer a no mínimo 70°F [20°C] e manter durante a soldagem (Tabela 5.11 nota de rodapé a).
Ferramenta de referência. Verificar contra a edição aplicável ao projeto e EPS aprovada pelo Engenheiro.

SAW (Submerged Arc Welding)

SAW submerges the arc beneath granular flux for highest deposition rates, flat/horizontal only. Category B in Table 5.11.

SAW on high-strength plate requires careful selection of wire-flux combinations to meet both tensile matching and toughness requirements. F8A4-EA2 or similar high-performance combinations serve Category C steels. Heat input control is particularly important on TMCP grades because SAW naturally deposits high heat input due to the deeply penetrating arc.

SAW Tips for High-Strength and TMCP Steels

For A913 Grades 50/60/65 TMCP shapes (CE-IIW 0.35–0.42), SAW is limited to flat-position shop fabrication of built-up sections — most A913 work involves W-shape splices welded in positions impractical for SAW. Where flat-position SAW is feasible, use 3/32" EM12K at 400–550 A with neutral flux. D1.1 Clause 7.7 heat input limitations do NOT apply to A913/A913M — SAW high heat.

Typical values for reference — always verify against your approved WPS and electrode manufacturer data.

Why SAW for A913 Gr.50/60/65 at up to 3/4"

Why SAW for A913 Gr.50/60/65 at up to 3/4"? SAW delivers 15-40 lb/hr deposition — the highest deposition rate among available processes. Position capability: flat and horizontal only. Suitability: shop only.

A913 Gr.50/60/65

ASTM A913 Grades 50 (50 ksi yield), 60 (60 ksi yield), and 65 (65 ksi yield) are quenched-and-self-tempered (QST) structural shapes produced by thermo-mechanical controlled processing (TMCP) — an in-line water quench immediately after the final rolling pass, followed by self-tempering from the core heat. This produces a fine-grained bainitic/ferritic microstructure throughout the full cross-section with carbon content typically 0.10-0.16% and CE-IIW of 0.35-0.42. Standard low-hydrogen processes use Category B; H8-certified consumables qualify for the reduced Category D (32°F all thicknesses), reflecting the inherent hydrogen cracking resistance of the TMCP microstructure. Available exclusively as W-shapes (primarily W14 heavy column sections), A913 is not produced as plate or other forms. The QST process eliminates the need for separate mill heat treatment, providing consistent through-thickness properties.

Por que Este Pré-aquecimento para A913 Gr.50/60/65 com SAW

TMCP structural shapes for seismic frames with H8-eligible reduced preheat. This steel is prequalified only with low-hydrogen processes under Table 5.11. With SAW, the submerged arc process with granular flux produces controlled hydrogen levels, with flux condition being the primary variable. The 32°F minimum preheat balances the steel’s strength level and carbon equivalent against the hydrogen control provided by SAW. Non-low-hydrogen SMAW is not an option for this grade under D1.1 prequalified WPS.

Aplicações Típicas de A913 Gr.50/60/65

Specified for seismic moment frame columns, high-rise building corner columns, transfer girder bearing seats, heavy truss chords, stadium cantilever support columns, and parking garage moment frame members. A913 TMCP shapes eliminate the need for post-rolling heat treatment, providing consistent through-thickness properties from flange tip to web center. Column splice CJP welds and beam-to-column continuity plate fillet welds are the critical weld joints. Available in W14 sections from W14x132 through W14x730, these shapes are the backbone of seismic column design in high-rise construction. The TMCP process creates a fine-grained microstructure throughout the full cross-section, unlike conventional heat-treated shapes that may have property gradients. The H8 path to Category D (32°F all thicknesses) offers significant fabrication cost savings on heavy column splices that would otherwise require 150-225°F preheat under Category B. Column flange thicknesses on W14x455 and heavier sections exceed 3".

Por que o Pré-aquecimento Importa em up to 3/4"

Thin material sheds heat quickly, allowing hydrogen to escape the HAZ readily — lowest preheat tier in Table 5.11.

Outros Aços com SAW em up to 3/4"

AçoCategoriaPré-aquecimento
A36B32°F (0°C)
A633 Gr.EC50°F (10°C)
A709 HPS70WC50°F (10°C)
A710 Gr.AC50°F (10°C)

Experimente Diferentes Combinações

Use a calculadora interativa de pré-aquecimento para consultar qualquer combinação de aço, processo e espessura da D1.1:2025 Tabela 5.11.

Qual é o pré-aquecimento mínimo para A913 Gr.50/60/65 com SAW em up to 3/4"?
Para A913 Gr.50/60/65 soldado com SAW em espessura up to 3/4", a temperatura mínima de pré-aquecimento é 32°F (0°C) conforme AWS D1.1:2025 Tabela 5.11, Categoria B. Esta é também a temperatura mínima de interpasse.
Qual categoria da Tabela 5.11 se aplica a A913 Gr.50/60/65 com SAW?
A913 Gr.50/60/65 soldado com SAW se enquadra na Categoria B da AWS D1.1:2025 Tabela 5.11. Processo SMAW, SAW, GMAW ou FCAW de baixo hidrogênio. Em espessura up to 3/4", esta categoria requer pré-aquecimento mínimo de 32°F (0°C).
A913 Gr.50/60/65 precisa de pré-aquecimento em up to 3/4"?
Em espessura up to 3/4" com SAW, o pré-aquecimento mínimo é 32°F (0°C) — efetivamente temperatura ambiente acima do congelamento. Não é necessário pré-aquecimento ativo a menos que o metal de base esteja abaixo de 32°F.