AWS A2.4 Section 13.1 · Flanged Joints

Edge Weld Symbol

The edge 溶接記号 appears in AWS A2.4 Figure 4.1 and is defined for parallel and flanged joints by AWS A2.4 Section 13.1. When CJP is required on flanged joints, AWS A2.4 Section 13.4 combines it with melt-through on shop drawings.

How to read an へり溶接 (エッジ溶接) symbol — the two parallel lines indicating a weld joining flanged or parallel edges. Common in sheet metal, less common in 構造用鋼. When to combine with melt-through.

Ask Flux
Edge Weld Symbol — Anatomy
bracket shape per A2.4
Basic edge weld
1/8 6 size left, length right
1/8" サイズ, 6" length
+ melt-through (CJP)
Edge + melt-through = CJP
weld flange flange fusion
Joint cross-section
Not a 開先溶接: Edge welds join flanged or parallel edges without machined preparation. 角形開先 welds join machined flat edges with controlled ルート間隙. Different symbols, different joints, different applications.

Edge Weld Symbol Dimensions

Per AWS A2.4 Section 13.1, the edge weld symbol is two short parallel vertical lines on the 基線. It represents a weld that fuses the full 板厚 of both member edges.

Use this symbol only when the joint really is an edge-weld condition: parallel edges, a flanged 突合せ継手, or a flanged 角継手. If the drawing is calling for prepared butt-継手形状, a square groove or another groove weld symbol is usually the cleaner AWS A2.4 reference. The edge weld symbol should not be used as a generic shortcut for every two-line joint symbol.

Where Each Dimension Goes

Size — to the LEFT when specified. This is the weld width or buildup thickness.

Length — to the RIGHT. The extent of the edge weld along the joint.

Joint Types

Parallel edge joint — two members with edges aligned side by side. The weld fuses the edges together.

Flanged butt joint — thin members with edges flanged (bent) to create a preparation for 溶接 from one side.

Flanged corner joint — one or both members flanged at a corner. The flange creates material for the weld.

Combining with Melt-Through

When CJP is required on a flanged joint welded from one side, add the melt-through symbol (filled semicircle) on the opposite side of the reference line per AWS A2.4 Section 13.4. This combination tells the 溶接士 that full penetration with visible 裏波 (ルート補強) is required.

The melt-through symbol is the important quality cue. Without it, the edge weld symbol identifies the joint and 溶接の種類, but it does not by itself prove complete 溶込み (継手溶込み). When 検査 requires back-side evidence, make the melt-through requirement explicit and 確認 the finished root condition against the governing drawing or procedure before accepting production welds at closeout and final documentation review.

D1.1 scope note: D1.1 does not have a dedicated edge weld 条項. Edge welds in structural steel appear mainly on miscellaneous light attachments. For sheet steel edge welds, AWS D1.3 is the governing 規格.

Edge Weld Symbol FAQ

What is an edge weld symbol?
An edge weld symbol consists of two short parallel vertical lines (like a bracket) placed above or below the reference line. It indicates a weld joining the edges of two or more members in a parallel, flanged butt, or flanged corner joint. The full thickness of both edges is fused together. Edge welds are more common in sheet metal fabrication than structural steel.
What is the difference between an edge weld and a square groove weld?
A square groove weld has machined flat edges with a controlled root opening for structural butt joints. An edge weld has flanged or parallel edges fused without machined preparation, common in light gauge sheet metal work. The square groove symbol is two parallel lines with defined root opening dimensions. The edge weld symbol also shows parallel lines but is used on flanged or parallel edge joints, not machined butt joints.
When should you combine the edge weld with the melt-through symbol?
When CJP (complete joint penetration) is required on a flanged joint and you are welding from one side only, add the melt-through symbol (filled semicircle) on the opposite side of the reference line. This tells the welder that full penetration with visible root reinforcement is required. The melt-through symbol confirms that the weld must melt completely through to the back side of the flanged joint.
Does AWS D1.1 cover edge welds?
D1.1 does not have a dedicated edge weld clause. Edge welds appear primarily in sheet metal work governed by AWS D1.3 (Structural Welding Code — Sheet Steel). In D1.1 scope, edge welds may appear on miscellaneous light attachments but are not a primary structural weld type. When they do appear, the general workmanship requirements of D1.1 apply.