AWS D1.1:2025 · Tabella 5.11 · Categoria G

Preriscaldo di A913 Gr.80 per SMAW-LH (H4) — 3/4" to 1-1/2"

Temperatura minima di preriscaldo e interpass per A913 Gr.80 saldato con SMAW-LH (H4) a spessore 3/4" to 1-1/2", secondo AWS D1.1:2025 Tabella 5.11.

Basato su AWS D1.1:2025 Tabella 5.11 — ogni valore tracciato alla clausola.

Temperatura Minima di Preriscaldo e Interpass
50°F / 10°C
Categoria G
Consumabili certificati H4 — controllo idrogeno più rigoroso
AWS D1.1:2025 Tabella 5.11, §5.7
Questa pagina mostra il preriscaldo con consumabili certificati H4. La designazione H4 è più rigorosa di H8 — non più di 4 mL di idrogeno diffusibile per 100g di metallo depositato, secondo AWS A4.3.
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A913 Gr.80

ASTM A913 Grade 80 (80 ksi yield, 95 ksi minimum tensile) is the highest-strength TMCP shape specification in D1.1, produced exclusively by the QST process. It requires H4-certified consumables (the strictest hydrogen control at ≤4 mL/100g deposited weld metal per AWS A4.3) and falls exclusively under Category G, which has four thickness-dependent preheat tiers (32°F up to 3/4”, 50°F up to 1-1/2”, 150°F up to 2-1/2”, 225°F above). No other hydrogen designation, standard low-hydrogen, or non-low-hydrogen SMAW is prequalified for this grade under Table 5.11. The H4 requirement limits the available consumable pool significantly — only select electrode classifications carry the H4 designator. A913 Gr.80 availability is limited to heavy W14 column sections from a small number of domestic and international mills, with procurement lead times typically 16-24 weeks.

Perché Questo Preriscaldo per A913 Gr.80 con SMAW-LH

Highest-strength 80 ksi TMCP shape requiring H4 consumables exclusively. This steel requires H4-certified consumables — the strictest hydrogen control in Table 5.11 at no more than 4 mL diffusible hydrogen per 100g. At 50°F with SMAW-LH, the four thickness-dependent preheat tiers in Category G reflect the balance between the steel's 80 ksi yield strength and the exceptional hydrogen control provided by H4 certification. No other hydrogen designation is prequalified for this grade.

Applicazioni Tipiche di A913 Gr.80

Reserved for the most demanding column applications in super-tall structures, typically interior gravity columns carrying 50+ stories of tributary load. A913 Gr.80 allows W14 sections to replace built-up box columns, simplifying connections and reducing fabrication cost while maintaining equivalent axial capacity. Every weld on this grade demands verified H4 consumables and documented preheat compliance — no exceptions or substitutions are permitted under Table 5.11. Column splice CJP welds require UT inspection per D1.1 Table 8.2. Only a limited number of domestic mills produce A913 Gr.80 shapes, with lead times of 16-24 weeks for non-stock sizes. The H4 consumable requirement eliminates most standard electrode inventory and requires dedicated electrode orders for each project. Fabricators must establish verified H4 supply chains before bidding Gr.80 column work, as H4-designated electrodes are not stocked by most welding distributors. Rejected consumable certifications can delay erection schedules by weeks.

Perché il Preriscaldo è Importante a 3/4" to 1-1/2"

Preheat climbs at this range as thicker material slows heat dissipation, trapping hydrogen at crack-susceptible grain boundaries.

Consumabili Certificati H4 per A913 Gr.80

La Categoria G è esclusiva per A913 Gr.80 e richiede consumabili certificati H4 — il controllo idrogeno più rigoroso in D1.1 con non più di 4 mL di idrogeno diffusibile per 100g di metallo depositato. I consumabili standard basso idrogeno o H8 non sono prequalificati per questa classe.

Prova Diverse Combinazioni

Usa il calcolatore interattivo di preriscaldo per consultare qualsiasi combinazione acciaio, processo e spessore dalla D1.1:2025 Tabella 5.11.

Qual è il preriscaldo minimo per A913 Gr.80 con SMAW-LH a 3/4" to 1-1/2"?
Per A913 Gr.80 saldato con SMAW-LH (H4) a spessore 3/4" to 1-1/2", la temperatura minima di preriscaldo è 50°F (10°C) secondo AWS D1.1:2025 Tabella 5.11, Categoria G.
Quale categoria della Tabella 5.11 si applica a A913 Gr.80 con SMAW-LH?
A913 Gr.80 saldato con SMAW-LH (H4) rientra nella Categoria G di AWS D1.1:2025 Tabella 5.11. Consumabili certificati H4 — controllo idrogeno più rigoroso. A spessore 3/4" to 1-1/2", questa categoria richiede un preriscaldo minimo di 50°F (10°C).
Cosa significa H4 per la saldatura di A913 Gr.80?
Il designatore supplementare H4 certifica che il consumabile deposita non più di 4 mL di idrogeno diffusibile per 100g di metallo depositato. Per A913 Gr.80, l'uso di consumabili H4 con SMAW-LH qualifica per la Categoria G con preriscaldo di 50°F a 3/4" to 1-1/2".

Dati di riferimento D1.1:2025. Non affiliato con AWS.