AWS D1.1:2025 · Tabella 5.11 · Categoria C

Preriscaldo di A913 Gr.70 per SMAW (low-hydrogen) — over 2-1/2"

Temperatura minima di preriscaldo e interpass per A913 Gr.70 saldato con SMAW (low-hydrogen) a spessore over 2-1/2", secondo AWS D1.1:2025 Tabella 5.11.

Basato su AWS D1.1:2025 Tabella 5.11 — ogni valore tracciato alla clausola.

Temperatura Minima di Preriscaldo e Interpass
300°F / 150°C
Categoria C
Processo SMAW, SAW, GMAW o FCAW basso idrogeno (acciai ad alta resistenza)
AWS D1.1:2025 Tabella 5.11, §5.7
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

SMAW (Low-Hydrogen)

Low-hydrogen SMAW (E7018/E7016) uses basic-coated electrodes requiring rod oven storage, assigned to Category B in Table 5.11.

For high-strength shapes and plate, E7018 provides adequate tensile match for steels up to Category C. E8018-C3 or E9018-M may be required for higher-strength steels to meet weld metal strength matching requirements. Bead sequencing on thick TMCP flanges should follow qualified WPS parameters precisely to avoid overheating the refined microstructure.

A913 Gr.70

ASTM A913 Grade 70 (70 ksi yield, 90 ksi minimum tensile) is a TMCP structural shape used in heavily loaded columns and seismic applications requiring higher strength than Gr.50/60/65. It falls under Category C for standard low-hydrogen processes, with preheat requirements reflecting its higher strength level and CE-IIW of approximately 0.42-0.48. With H8-certified consumables, it qualifies for Category F — 32°F up to 2-1/2”, 150°F above. The TMCP QST microstructure provides inherent resistance to hydrogen cracking through its fine-grained bainitic structure, which is why H8 consumables unlock a reduced-preheat path not available for conventional Q&T steels at similar strength. A913 Gr.70 is primarily available in W14 sections ranging from W14x233 through W14x730, with limited W12 and W36 availability.

Perché Questo Preriscaldo per A913 Gr.70 con SMAW-LH

TMCP 70 ksi shape with Category F reduced preheat using H8 consumables. The higher strength level of this steel places it in Category C of Table 5.11, which carries elevated preheat requirements compared to Category B grades. At 300°F minimum with SMAW-LH, the preheat ensures the cooling rate stays slow enough to prevent hydrogen-induced cracking in this higher-hardenability material. Category C steels demand careful attention to interpass temperature control throughout the weld sequence.

Applicazioni Tipiche di A913 Gr.70

Used in heavily loaded interior columns of super-tall buildings, transfer truss compression chords, mega-brace members in outrigger systems, stadium roof cantilever supports, and seismic collectors in high-rise cores. A913 Gr.70 TMCP shapes enable smaller column sections, freeing usable floor space on every floor of the building. Column splice butt welds at upper stories and moment connection flange welds carry the highest inspection priority. The 70 ksi yield enables using W14x398 where conventional Gr.50 would require W14x550, saving 38% in material weight and 3-4 inches of floor space per column. Erection splices at every 2-3 stories use CJP groove welds with backing bars removed and back-gouged per seismic detailing requirements. The Category F path with H8 consumables (32°F up to 2-1/2", 150°F above) provides a practical alternative to full Category C preheat on these thick-flange column splices.

Perché il Preriscaldo è Importante a over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Preriscaldo Categoria C per A913 Gr.70

La Categoria C nella Tabella 5.11 si applica agli acciai ad alta resistenza dove la combinazione di temprabilità e tensione residua richiede un preriscaldo elevato. Per A913 Gr.70 a over 2-1/2", il preriscaldo minimo di 300°F rallenta la velocità di raffreddamento della saldatura per prevenire la formazione di martensite suscettibile a cricche nella zona termicamente alterata.

Altri Acciai con SMAW (low-hydrogen) a over 2-1/2"

AcciaioCategoriaPreriscaldo
A36B225°F (110°C)
A53 Gr.BB225°F (110°C)
A106 Gr.BB225°F (110°C)
A633 Gr.EC300°F (150°C)

Prova Diverse Combinazioni

Usa il calcolatore interattivo di preriscaldo per consultare qualsiasi combinazione acciaio, processo e spessore dalla D1.1:2025 Tabella 5.11.

Qual è il preriscaldo minimo per A913 Gr.70 con SMAW-LH a over 2-1/2"?
Per A913 Gr.70 saldato con SMAW (low-hydrogen) a spessore over 2-1/2", la temperatura minima di preriscaldo è 300°F (150°C) secondo AWS D1.1:2025 Tabella 5.11, Categoria C.
Quale categoria della Tabella 5.11 si applica a A913 Gr.70 con SMAW-LH?
A913 Gr.70 saldato con SMAW (low-hydrogen) rientra nella Categoria C di AWS D1.1:2025 Tabella 5.11. Processo SMAW, SAW, GMAW o FCAW basso idrogeno (acciai ad alta resistenza). A spessore over 2-1/2", questa categoria richiede un preriscaldo minimo di 300°F (150°C).
Perché il preriscaldo è 300°F per A913 Gr.70 a over 2-1/2"?
Il preriscaldo di 300°F per A913 Gr.70 a over 2-1/2" con SMAW (low-hydrogen) riflette la combinazione della temprabilità dell'acciaio e del vincolo aumentato a questo spessore.

Dati di riferimento D1.1:2025. Non affiliato con AWS.