AWS D1.1:2025 · Tabella 5.11 · Categoria A

Preriscaldo di A709 Gr.36 per SMAW (non-low-hydrogen) — over 2-1/2"

Temperatura minima di preriscaldo e interpass per A709 Gr.36 saldato con SMAW (non-low-hydrogen) a spessore over 2-1/2", secondo AWS D1.1:2025 Tabella 5.11.

Basato su AWS D1.1:2025 Tabella 5.11 — ogni valore tracciato alla clausola.

Temperatura Minima di Preriscaldo e Interpass
300°F / 150°C
Categoria A
Processo SMAW non basso idrogeno
AWS D1.1:2025 Tabella 5.11, §5.7
Strumento di riferimento. Verificare contro l'edizione applicabile e WPS approvata dall'Ingegnere.

SMAW (Non-Low-Hydrogen)

Non-low-hydrogen SMAW (E6010/E6011) uses cellulosic electrodes with higher hydrogen potential, assigned to Category A in Table 5.11.

For common structural shapes and plate, non-low-hydrogen SMAW with E6010 or E6011 excels at root passes on open-root groove welds where burn-through control matters. Vertical-up technique with a slight weave keeps the puddle manageable. Rod consumption runs about 10-12 electrodes per pound of weld metal deposited. Electrode stubs should be no shorter than 2 inches to maintain adequate arc length control.

A709 Gr.36

ASTM A709 Grade 36 is the bridge-specific equivalent of A36, used exclusively for highway bridge construction under AASHTO LRFD Bridge Design Specifications. With 36 ksi minimum yield, 58-80 ksi tensile, and mandatory Charpy V-notch testing requirements based on AASHTO temperature zone (Zone 1: 70°F, Zone 2: 40°F, Zone 3: 10°F test temperatures), it qualifies for both Category A and Category B preheat in Table 5.11. Chemistry matches A36 (0.26% max carbon) but the CVN requirements add a fracture resistance guarantee absent from plain A36. A709 Gr.36 is primarily used for secondary bridge members — lateral bracing, floor beam stiffeners, diaphragm plates, and bearing components — where Gr.50 strength is not needed but bridge-code CVN compliance is required.

Perché Questo Preriscaldo per A709 Gr.36 con SMAW

Bridge-specific 36 ksi grade with CVN testing for highway construction. At this thickness, SMAW with non-low-hydrogen electrodes places the joint in Category A of Table 5.11. The minimum preheat of 300°F compensates for the higher diffusible hydrogen from cellulosic electrode coatings. The thicker the material, the longer hydrogen takes to escape the heat-affected zone, which is why preheat rises with thickness even for this common grade.

Applicazioni Tipiche di A709 Gr.36

Specified exclusively for highway bridge deck plate, floor beams, lateral bracing, secondary framing, bridge railing posts, abutment bearing stiffeners, and diaphragm plates. A709 Gr.36 requires CVN testing per AASHTO zone classification, distinguishing it from plain A36 by guaranteeing fracture resistance at the bridge’s design service temperature. Transverse stiffener fillet welds and floor beam web-to-flange joints are high-frequency fabrication details in bridge shops. The fracture-critical designation on certain bridge members imposes additional NDT requirements (UT in lieu of RT for CJP welds) and welder qualification testing beyond standard D1.5 provisions. Temperature zones (1 through 3) determine the CVN test temperature for the Charpy specimens: Zone 1 at 70°F for moderate climates, Zone 2 at 40°F for cold climates, and Zone 3 at 10°F for severe cold. Mill certifications must show CVN results meeting the specified zone before plate release to the bridge fabricator.

Perché il Preriscaldo è Importante a over 2-1/2"

The heaviest sections demand the highest preheat in Table 5.11. Multi-pass sequences require maintaining interpass temperature throughout.

Altri Acciai con SMAW (non-low-hydrogen) a over 2-1/2"

AcciaioCategoriaPreriscaldo
A36A300°F (150°C)
A53 Gr.BA300°F (150°C)

Prova Diverse Combinazioni

Usa il calcolatore interattivo di preriscaldo per consultare qualsiasi combinazione acciaio, processo e spessore dalla D1.1:2025 Tabella 5.11.

Qual è il preriscaldo minimo per A709 Gr.36 con SMAW a over 2-1/2"?
Per A709 Gr.36 saldato con SMAW (non-low-hydrogen) a spessore over 2-1/2", la temperatura minima di preriscaldo è 300°F (150°C) secondo AWS D1.1:2025 Tabella 5.11, Categoria A.
Quale categoria della Tabella 5.11 si applica a A709 Gr.36 con SMAW?
A709 Gr.36 saldato con SMAW (non-low-hydrogen) rientra nella Categoria A di AWS D1.1:2025 Tabella 5.11. Processo SMAW non basso idrogeno. A spessore over 2-1/2", questa categoria richiede un preriscaldo minimo di 300°F (150°C).
Perché il preriscaldo è 300°F per A709 Gr.36 a over 2-1/2"?
Il preriscaldo di 300°F per A709 Gr.36 a over 2-1/2" con SMAW (non-low-hydrogen) riflette la combinazione della temprabilità dell'acciaio e del vincolo aumentato a questo spessore.

Dati di riferimento D1.1:2025. Non affiliato con AWS.